Changes

no edit summary
Line 2: Line 2:  
With an increasing demand for cold-chain supply chains, Teltonika is offering the ability to monitor real-time information from freezer trailer thermographs. Each thermograph has an RS232 communication line where {{{model|}}} devices can connect via COM1/COM2 port of the device. The solution is easy to install and configure. This allows you to monitor the main information of the freezer trailer such as Temperature, Fridge door status, Alarms, etc., and generate events according to your needs. For more information please refer to the installation manual below.
 
With an increasing demand for cold-chain supply chains, Teltonika is offering the ability to monitor real-time information from freezer trailer thermographs. Each thermograph has an RS232 communication line where {{{model|}}} devices can connect via COM1/COM2 port of the device. The solution is easy to install and configure. This allows you to monitor the main information of the freezer trailer such as Temperature, Fridge door status, Alarms, etc., and generate events according to your needs. For more information please refer to the installation manual below.
   −
'''NOTE:''' this feature is available from FW ver. '''01.02.02.Rev.00'''
+
'''NOTE:''' this feature is available from FW ver. '''01.02.23.Rev.00'''
    
==Supported Thermographs==
 
==Supported Thermographs==
   −
{{{model|}}} can be connecteds to DataCold600, Transcan2, TouchPrint thermographs.
+
{{{model|}}} can be connected to Euroscan, DataCold600, Transcan2, TouchPrint thermographs.
   −
Refer to the table bellow to see which freezers use which thermograph:
+
Refer to the table below to see which freezers use which thermograph:
{| class="wikitable"
+
{| class="wikitable"  
|+
  −
!
  −
|Thermograph Type
  −
!
  −
!
   
|-
 
|-
|Freezer Type
+
!
|DataCold600
+
! colspan="4" style="text-align:center; font-weight:bold;" | Thermograph Type
|Transcan2
  −
|TouchPrint
   
|-
 
|-
|Carrier
+
| style="font-weight:bold;" | Freezer Type
 +
| Euroscan
 +
| DataCold600
 +
| Transcan2
 +
| TouchPrint/TouchLog
 +
|-
 +
| Carrier
 +
| +
 
| +
 
| +
 
| -
 
| -
 
| -
 
| -
 
|-
 
|-
|ThermoKing
+
| ThermoKing
 +
| +<br />
 
| -
 
| -
 
| +
 
| +
Line 39: Line 40:  
==Installation guide==
 
==Installation guide==
   −
=== '''Touchprint'''===
+
=== '''TouchPrint/TouchLog'''===
[[File:Thermoking.png|center|frameless|665x665px]]
+
[[File:506581 Thermograph Touchprint.png|404x404px]]
 +
<br></br>
 +
'''TouchPrint pinout''':
 +
<br></br>
 +
[[File:517441 TOUCHPRINT PINOUT.jpg]]
 +
<br></br>
 +
No configuration is necessary.
    +
If the equipment does not receive information from the thermographer, the speed of the port accessing the configuration menu:
   −
No configuration is necessary.
+
Keep the blue and red buttons pressed at the same time. "Enter PIN code" is displayed on the screen, enter pin "1111" by pressing the blue button four times. Travel for the options with the red button.
   −
If the equipment does not receive information from the thermographer, the speed of the port accessing the configuration menu:
+
The ENG Display> OFF option must be ON, change its value with the keys ◄ and ►. Once switched to ON, keep scrolling through the options until you find Baud Rate> 9600. The value should be 9600, otherwise, adjust the speed by moving the cursor with the ◄ and ► keys, and adjust the speed with the keys ▲ and ▼.
   −
Keep the blue and red buttons pressed at the same time. "Enter PIN code" is displayed in screen, enter pin "1111" by pressing the blue button four times. Travel for the options with the red button.
+
<br></br>
 +
'''TouchLog pinout''':
 +
<br></br>
 +
[[File:517635 TOUCHPLOG PINOUT V1.1.jpg]]
 +
<br></br>
 +
<br></br>
   −
The ENG Display> OFF option must be ON, change its value with the keys ◄ and ►. Once switched to ON, keep scrolling through the options until find Baud Rate> 9600. The value should be 9600, otherwise adjust the speed by moving the cursor with the ◄ and ► keys, and adjust speed with the keys ▲ and ▼.
     −
==='''Transcan'''===
+
AVL IDs for Touchprint:
[[File:Transcan.png|center|frameless|545x545px]]
+
{| class="wikitable" style="font-weight:bold; text-align:center;"
Same connections as the ThermoKing thermograph.
+
|-
 +
! style="vertical-align:middle;" | Parameter name
 +
! style="vertical-align:middle;" | Input 1
 +
! style="vertical-align:middle;" | Input 2
 +
! style="vertical-align:middle;" | Input 3
 +
! style="vertical-align:middle;" | Input 4
 +
! style="vertical-align:middle;" | Input 5
 +
! style="vertical-align:middle;" | Input 6
 +
! style="vertical-align:middle;" | Setpoint 1
 +
! style="vertical-align:middle;" | Setpoint 2
 +
! style="vertical-align:middle;" | Setpoint 3
 +
|-
 +
| AVL ID
 +
| 10695
 +
| 10696
 +
| 10697
 +
| 10698
 +
| 10699
 +
| 10700
 +
| 10701
 +
| 10702
 +
| 10703
 +
|}
    
Configuration: No configuration is necessary.
 
Configuration: No configuration is necessary.
Line 60: Line 94:     
==='''Carrier Datacold 600'''===
 
==='''Carrier Datacold 600'''===
[[File:Carrier Datacold 600.png|center|frameless|693x693px]]
+
To properly use DataCold 600 with FMX640 these steps must be followed:
Press the green button for 4 seconds.
+
*In FMX640 RS232 settings '''DataCold mode''' is selected and '''Baudrate set to 38400'''
 +
*'''Partner mode enabled''' on DataCold 600
 +
<br></br>
   −
→ "Enter PIN" is displayed, enter "1111" with the blue button.
+
[[File:511336 Thermograph data cold colour .png|693x693px]]
   −
→ Choose Communication Setup menu with the blue button.
     −
→ Configure COM1 or COM2 depending on the connection:
+
To enable Partner mode on DataCold 600:
 +
# Press and hold the green button for 4 seconds
 +
# Insert password. Default password - 1111
 +
# Press the blue button to open 11 communication settings
 +
# Press the green button to select edit action
 +
# 11.1.0 Com1 Port settings should be opened, then press the green button again
 +
# Then search for Partner protocol and press the green button to accept changes
 +
<br></br>
 +
Important note - RX and TX are inverted via the RS-232 connection. Scheme to properly manage DataCold 600 RS232 connection:
 +
Pinout of DataCold600
 +
[[File:517440 DataCold PINOUT.jpg]]
 +
<br></br>
 +
Available parameters (AVL IDs) with DataCold 600:
 +
{| class="wikitable" style="font-weight:bold; text-align:center;"
 +
|-
 +
! style="vertical-align:middle;" | Parameter name
 +
! style="vertical-align:middle;" | Zone 1 Compartment state
 +
! style="vertical-align:middle;" | Zone 1 Compartment mode
 +
! style="vertical-align:middle;" | Zone 1 Return Air Sensor
 +
! style="vertical-align:middle;" | Zone 1 Supply Air Sensor
 +
! style="vertical-align:middle;" | Zone 1 Set Temperature
 +
! style="vertical-align:middle;" | Zone 1 Evaporator temperature
 +
! style="vertical-align:middle;" | Zone 2 Return Air Sensor
 +
! style="vertical-align:middle;" | Zone 2 Supply Air Sensor
 +
! style="vertical-align:middle;" | Zone 2 Set Temperature
 +
! style="vertical-align:middle;" | Zone 3 Compartment state
 +
! style="vertical-align:middle;" | Zone 3 Compartment mode
 +
! style="vertical-align:middle;" | Zone 3 Set Temperature
 +
|-
 +
| AVL ID
 +
| 10045
 +
| 10046
 +
| 10047
 +
| 10048
 +
| 10049
 +
| 10050
 +
| 10056
 +
| 10057
 +
| 10058
 +
| 10063
 +
| 10064
 +
| 10067
 +
|}
 +
{| class="wikitable" style="font-weight:bold; text-align:center;"
 +
|-
 +
! style="vertical-align:middle;" | Parameter name
 +
! style="vertical-align:middle;" | Speed mode
 +
! style="vertical-align:middle;" | Ambient Air Temperature
 +
! style="vertical-align:middle;" | Compressor Config
 +
! style="vertical-align:middle;" | Installation Serial
 +
! style="vertical-align:middle;" | Analog Input 1-3
 +
! style="vertical-align:middle;" | Manufacturer ID
 +
! style="vertical-align:middle;" | Battery State Flags
 +
! style="vertical-align:middle;" | Fuel state flags
 +
! style="vertical-align:middle;" | Maintenance 1-5 Hours
 +
! style="vertical-align:middle;" | Run Mode
 +
! style="vertical-align:middle;" | Error Codes
 +
! style="vertical-align:middle;" | Temperature Probe 1-6
 +
|-
 +
| AVL ID
 +
| 10071
 +
| 10350
 +
| 10353
 +
| 10356
 +
| 10468-10470
 +
| 10472
 +
| 10473
 +
| 10474
 +
| 10475-10479
 +
| 10480
 +
| 10639
 +
| 10644-10649
 +
|}
   −
"11.1 COM 1 port settings" will be shown on the display.
+
<br></br>
 +
Run mode explanation:
 +
{| class="wikitable" style="font-weight:bold;"
 +
|-
 +
! Run mode
 +
! StartStop
 +
! Continious
 +
! CycleCentry
 +
! Unknown/Now available
 +
|- style="font-weight:normal;"
 +
| style="font-weight:bold;" | Value (HEX)
 +
| 0
 +
| 1
 +
| 2
 +
| 7
 +
|}
 +
<br></br>
 +
Fuel and Battery state flag explanation:
 +
{| class="wikitable" style="font-weight:bold;"
 +
|-
 +
! Fuel/Battery Flag Status
 +
! Available
 +
! Error
 +
! Alarm
 +
! Digital sensor
 +
|- style="font-weight:normal;"
 +
| style="font-weight:bold;" | Enum (bit field) value
 +
| 0
 +
| 1
 +
| 2
 +
| 3
 +
|}
   −
Select the default value, "UCP protocol" with the yellow or blue button.
+
==='''Euroscan'''===
 +
To properly use Euroscan with FMX640 these steps must be followed:
 +
*In FMX640 RS232 settings '''Euroscan mode''' is selected and '''Baudrate set to 38400'''
 +
*'''Partner mode enabled''' on Euroscan
 +
<br></br>
   −
Confirm selection with the green button. Press the red button twice to access the
+
[[File:511336 Thermograph data cold colour .png|693x693px]]
   −
main menu.
     −
==Configuration==
+
To enable Partner mode on Euroscan :
 +
# Press and hold the green button for 4 seconds
 +
# Insert password. Default password - 1111
 +
# Press the blue button to open 11 communication settings
 +
# Press the green button to select edit action
 +
# 11.1.0 Com1 Port settings should be opened, then press the green button again
 +
# Then search for Partner protocol and press the green button to accept changes
 +
<br></br>
 +
Important note - RX and TX are inverted via the RS-232 connection. Scheme to properly manage Euroscan  RS232 connection:
 +
Pinout of DataCold600
 +
[[File:517440 DataCold PINOUT.jpg]]
 +
<br></br>
 +
Available parameters (AVL IDs) with Euroscan :
   −
Make sure the {{{model|}}} device is configured to receive data from “Transcan2 Reefer”, "Touchprint Reefer" or "DataCold Reefer". To do this, enter the configurator window, select the RS232 \ RS485 section displayed in the screenshots below, and configure accordingly (COM1/COM2 Settings, Mode “Transcan2 Reefer”, "Touchprint Reefer" or "DataCold Reefer", Baudrate: Default)
     −
[[File:Transcan2_Reefer_2021_08_12.png|alt=|frameless|746x746px]][[File:Touchprint_Reefer_2021_08_12.png|alt=|frameless|746x746px]]
+
{| class="wikitable" style="font-weight:bold; text-align:center;"
 +
|-
 +
! style="vertical-align:middle;" | External Sensor Temperature 1
 +
! style="vertical-align:middle;" | External Sensor Temperature 2
 +
! style="vertical-align:middle;" | External Sensor Temperature 3
 +
! style="vertical-align:middle;" | External Sensor Temperature 4
 +
! style="vertical-align:middle;" | External Sensor Temperature 5
 +
! style="vertical-align:middle;" | External Sensor Temperature 6
 +
! style="vertical-align:middle;" | Digital Sensor 1
 +
! style="vertical-align:middle;" | Digital Sensor 2
 +
! style="vertical-align:middle;" | Digital Sensor 3
 +
! style="vertical-align:middle;" | Digital Sensor 4
 +
|-
 +
| 484
 +
| 485
 +
| 486
 +
| 487
 +
| 488
 +
| 489
 +
| 10464
 +
| 10465
 +
| 10466
 +
| 10467
 +
|}
   −
[[File:DataCold Reefer 2021 08 20.png|frameless|739x739px]]
+
==Configuration==
    +
Make sure the {{{model|}}} device is configured to receive data from “Transcan2 Reefer”, "Touchprint Reefer", "Euroscan: or "DataCold Reefer". To do this, enter the configurator window, select the RS232 \ RS485 section displayed in the screenshots below, and configure accordingly (COM1/COM2 Settings, Mode “Transcan2 Reefer”, "Touchprint Reefer", "Euroscan"or "DataCold Reefer", Baudrate: Default)
 +
 +
[[File:RS-232 refer.png]]
 
==== DataCold Reefer ====
 
==== DataCold Reefer ====
      
To configure "DataCold Reefer" I/O parameters, please select "Reefer IO":
 
To configure "DataCold Reefer" I/O parameters, please select "Reefer IO":
 +
[[File:ReeferIO.png]]
 +
<br></br>
 +
Data sending parameters (AVL ID) used for "DataCold Reefer" are these: 10040 - 10649. For more in-depth information, please refer to '''[[{{{model|}}}_Teltonika_Data_Sending_Parameters_ID#Reefer_IO|Reefer IO data sending parameters]].'''
   −
[[File:Reefer IO settings.png|frameless|1000x1000px]]
+
==== TK Transcan2 Reefer ====
 
  −
Data sending parameters (AVL ID) used for "DataCold Reefer" are these: 10040 - 10649. For more in-depth information, please refer to '''[[{{{model|}}} Teltonika Data Sending Parameters ID#Freezer_IO|Data Sending Parameters page]].'''
  −
 
  −
==== Transcan2 Reefer ====
   
To configure "Transcan2 Reefer" I/O parameters, please select "TK Transcom IO":
 
To configure "Transcan2 Reefer" I/O parameters, please select "TK Transcom IO":
 +
[[File:TranscanIO.png]]
 +
<br></br>
 +
Data sending parameters (AVL ID) used for "Transcan2
 +
" are these: 10683 - 10694. For more in-depth information, please refer to '''[[{{{model|}}}_Teltonika_Data_Sending_Parameters_ID#TK_Transcan_IO|Transcan IO data sending parameters]]'''
   −
[[File:Transcom IO settings.png|frameless|1000x1000px]]
+
==== Euroscan IO====
 +
To configure "Euroscan refeer" I/O parameters select "Euroscan IO":
 +
[[File:EuroScanIO.png]]
 +
<br></br>
 +
Data sending parameters (AVL ID) used for "Euroscan" are these: 484-489 and 10464-10467. For more in-depth information, please refer to '''[[{{{model|}}}_Teltonika_Data_Sending_Parameters_ID#TK_Euroscan_IO|Euroscan IO data sending parameters]].'''
   −
Data sending parameters (AVL ID) used for "Transcan2 Reefer" are these: 10683 - 10694. For more in-depth information, please refer to '''[[{{{model|}}} Teltonika Data Sending Parameters ID#Freezer_IO|Data Sending Parameters page]].'''
+
==== TK Touchprint/Touchlog I/O ====
 
  −
==== Touchprint Reefer ====
   
To configure "Touchprint Reefer" I/O parameters select "TK Touchprint IO":
 
To configure "Touchprint Reefer" I/O parameters select "TK Touchprint IO":
   −
[[File:Touchprint Reefer IO settings.png|frameless|1000x1000px]]
+
[[File:TouchprintIO.png]]
 
+
<br></br>
Data sending parameters (AVL ID) used for "Touchprint Reefer" are these: 10695 - 10703. For more in-depth information, please refer to '''[[{{{model|}}} Teltonika Data Sending Parameters ID#Freezer_IO|Data Sending Parameters page]].'''
+
Data sending parameters (AVL ID) used for "Touchprint Reefer" are these: 10695 - 10703. For more in-depth information, please refer to '''[[{{{model|}}}_Teltonika_Data_Sending_Parameters_ID#TK_Touchprint_IO|Touchprint IO data sending parameters]].'''
  −
 
         
[[Codec#Codec_8_Extended |Codec 8 Extended]] should be selected as the main data protocol in the “Protocol Settings” tab, which is located in the “System” section.
 
[[Codec#Codec_8_Extended |Codec 8 Extended]] should be selected as the main data protocol in the “Protocol Settings” tab, which is located in the “System” section.
   −
[[image:Reefer3.png|center]]
  −
[[Category:{{{model|}}}]]
   
[[Category:{{{model|}}} Manual]]
 
[[Category:{{{model|}}} Manual]]

Navigation menu