==Introduction==
 
==Introduction==
Withsss an increasing demand for cold-chain supply chains, Teltonika is offering the ability to monitor real-time information from freezer trailer thermographs. Each thermograph has an RS232 communication line where {{{model|}}} devices can connect via COM1/COM2 port of the device. The solution is easy to install and configure. This allows you to monitor the main information of the freezer trailer such as Temperature, Fridge door status, Alarms, etc., and generate events according to your needs. For more information please refer to the installation manual below.
+
With an increasing demand for cold-chain supply chains, Teltonika is offering the ability to monitor real-time information from freezer trailer thermographs. Each thermograph has an RS232 communication line where {{{model|}}} devices can connect via COM1/COM2 port of the device. The solution is easy to install and configure. This allows you to monitor the main information of the freezer trailer such as Temperature, Fridge door status, Alarms, etc., and generate events according to your needs. For more information please refer to the installation manual below.
   −
'''NOTE:''' this feature is available from FW ver. '''01.02.02.Rev.00'''
+
'''NOTE:''' this feature is available from FW ver. '''01.02.23.Rev.00'''
    
==Supported Thermographs==
 
==Supported Thermographs==
   −
{{{model|}}} can be connecteds to DataCold600, Transcan2, TouchPrint thermographs.
+
{{{model|}}} can be connected to Euroscan, DataCold600, Transcan2, TouchPrint thermographs.
   −
Refer to the table bellow to see which freezers use which thermograph:
+
Refer to the table below to see which freezers use which thermograph:
{| class="wikitable"
+
{| class="wikitable"  
|+
  −
!
  −
|Thermograph Type
  −
!
  −
!
   
|-
 
|-
|Freezer Type
+
!
|DataCold600
+
! colspan="4" style="text-align:center; font-weight:bold;" | Thermograph Type
|Transcan2
  −
|TouchPrint
   
|-
 
|-
|Carrier
+
| style="font-weight:bold;" | Freezer Type
 +
| Euroscan
 +
| DataCold600
 +
| Transcan2
 +
| TouchPrint/TouchLog
 +
|-
 +
| Carrier
 +
| +
 
| +
 
| +
 
| -
 
| -
 
| -
 
| -
 
|-
 
|-
|ThermoKing
+
| ThermoKing
 +
| +<br />
 
| -
 
| -
 
| +
 
| +
Line 39: Line 40:  
==Installation guide==
 
==Installation guide==
   −
=== '''Touchprint'''===
+
=== '''TouchPrint/TouchLog'''===
[[File:Thermoking.png|center|frameless|665x665px]]
+
[[File:506581 Thermograph Touchprint.png|404x404px]]  
 
+
<br></br>
 
+
'''TouchPrint pinout''':
 +
<br></br>
 +
[[File:517441 TOUCHPRINT PINOUT.jpg]]
 +
<br></br>
 
No configuration is necessary.
 
No configuration is necessary.
    
If the equipment does not receive information from the thermographer, the speed of the port accessing the configuration menu:
 
If the equipment does not receive information from the thermographer, the speed of the port accessing the configuration menu:
   −
Keep the blue and red buttons pressed at the same time. "Enter PIN code" is displayed in screen, enter pin "1111" by pressing the blue button four times. Travel for the options with the red button.
+
Keep the blue and red buttons pressed at the same time. "Enter PIN code" is displayed on the screen, enter pin "1111" by pressing the blue button four times. Travel for the options with the red button.
   −
The ENG Display> OFF option must be ON, change its value with the keys ◄ and ►. Once switched to ON, keep scrolling through the options until find Baud Rate> 9600. The value should be 9600, otherwise adjust the speed by moving the cursor with the ◄ and ► keys, and adjust speed with the keys ▲ and ▼.
+
The ENG Display> OFF option must be ON, change its value with the keys ◄ and ►. Once switched to ON, keep scrolling through the options until you find Baud Rate> 9600. The value should be 9600, otherwise, adjust the speed by moving the cursor with the ◄ and ► keys, and adjust the speed with the keys ▲ and ▼.
 +
 
 +
<br></br>
 +
'''TouchLog pinout''':
 +
<br></br>
 +
[[File:517635 TOUCHPLOG PINOUT V1.1.jpg]]
 +
<br></br>
 +
<br></br>
   −
==='''Transcan'''===
+
 
[[File:Transcan.png|center|frameless|545x545px]]
+
AVL IDs for Touchprint:
Same connections as the ThermoKing thermograph.
+
{| class="wikitable" style="font-weight:bold; text-align:center;"
 +
|-
 +
! style="vertical-align:middle;" | Parameter name
 +
! style="vertical-align:middle;" | Input 1
 +
! style="vertical-align:middle;" | Input 2
 +
! style="vertical-align:middle;" | Input 3
 +
! style="vertical-align:middle;" | Input 4
 +
! style="vertical-align:middle;" | Input 5
 +
! style="vertical-align:middle;" | Input 6
 +
! style="vertical-align:middle;" | Setpoint 1
 +
! style="vertical-align:middle;" | Setpoint 2
 +
! style="vertical-align:middle;" | Setpoint 3
 +
|-
 +
| AVL ID
 +
| 10695
 +
| 10696
 +
| 10697
 +
| 10698
 +
| 10699
 +
| 10700
 +
| 10701
 +
| 10702
 +
| 10703
 +
|}
    
Configuration: No configuration is necessary.
 
Configuration: No configuration is necessary.
Line 64: Line 98:  
*'''Partner mode enabled''' on DataCold 600
 
*'''Partner mode enabled''' on DataCold 600
 
<br></br>
 
<br></br>
 +
 +
[[File:511336 Thermograph data cold colour .png|693x693px]]
 +
 +
 
To enable Partner mode on DataCold 600:
 
To enable Partner mode on DataCold 600:
 
# Press and hold the green button for 4 seconds
 
# Press and hold the green button for 4 seconds
Line 73: Line 111:  
<br></br>
 
<br></br>
 
Important note - RX and TX are inverted via the RS-232 connection. Scheme to properly manage DataCold 600 RS232 connection:
 
Important note - RX and TX are inverted via the RS-232 connection. Scheme to properly manage DataCold 600 RS232 connection:
 
+
Pinout of DataCold600
[[File:Carrier Datacold 600.png|693x693px]]
+
[[File:517440 DataCold PINOUT.jpg]]
 
+
<br></br>
Available parameters with DataCold 600:
+
Available parameters (AVL IDs) with DataCold 600:
 +
{| class="wikitable" style="font-weight:bold; text-align:center;"
 +
|-
 +
! style="vertical-align:middle;" | Parameter name
 +
! style="vertical-align:middle;" | Zone 1 Compartment state
 +
! style="vertical-align:middle;" | Zone 1 Compartment mode
 +
! style="vertical-align:middle;" | Zone 1 Return Air Sensor
 +
! style="vertical-align:middle;" | Zone 1 Supply Air Sensor
 +
! style="vertical-align:middle;" | Zone 1 Set Temperature
 +
! style="vertical-align:middle;" | Zone 1 Evaporator temperature
 +
! style="vertical-align:middle;" | Zone 2 Return Air Sensor
 +
! style="vertical-align:middle;" | Zone 2 Supply Air Sensor
 +
! style="vertical-align:middle;" | Zone 2 Set Temperature
 +
! style="vertical-align:middle;" | Zone 3 Compartment state
 +
! style="vertical-align:middle;" | Zone 3 Compartment mode
 +
! style="vertical-align:middle;" | Zone 3 Set Temperature
 +
|-
 +
| AVL ID
 +
| 10045
 +
| 10046
 +
| 10047
 +
| 10048
 +
| 10049
 +
| 10050
 +
| 10056
 +
| 10057
 +
| 10058
 +
| 10063
 +
| 10064
 +
| 10067
 +
|}
 
{| class="wikitable" style="font-weight:bold; text-align:center;"
 
{| class="wikitable" style="font-weight:bold; text-align:center;"
 
|-
 
|-
 
! style="vertical-align:middle;" | Parameter name
 
! style="vertical-align:middle;" | Parameter name
! style="vertical-align:middle;" | Power mode
   
! style="vertical-align:middle;" | Speed mode
 
! style="vertical-align:middle;" | Speed mode
 
! style="vertical-align:middle;" | Ambient Air Temperature
 
! style="vertical-align:middle;" | Ambient Air Temperature
! style="vertical-align:middle;" | Alarm level
+
! style="vertical-align:middle;" | Compressor Config
! style="vertical-align:middle;" | Communication state flags
+
! style="vertical-align:middle;" | Installation Serial
 +
! style="vertical-align:middle;" | Analog Input 1-3
 
! style="vertical-align:middle;" | Manufacturer ID
 
! style="vertical-align:middle;" | Manufacturer ID
 
! style="vertical-align:middle;" | Battery State Flags
 
! style="vertical-align:middle;" | Battery State Flags
 
! style="vertical-align:middle;" | Fuel state flags
 
! style="vertical-align:middle;" | Fuel state flags
 +
! style="vertical-align:middle;" | Maintenance 1-5 Hours
 
! style="vertical-align:middle;" | Run Mode
 
! style="vertical-align:middle;" | Run Mode
! style="vertical-align:middle;" | Fridge Error Codes
+
! style="vertical-align:middle;" | Error Codes
! style="vertical-align:middle;" | Fridge Temperature Probe 1-6
+
! style="vertical-align:middle;" | Temperature Probe 1-6
! External Digital Sensor 1-4
+
|-
! External Analog Input 1-4
+
| AVL ID
 +
| 10071
 +
| 10350
 +
| 10353
 +
| 10356
 +
| 10468-10470
 +
| 10472
 +
| 10473
 +
| 10474
 +
| 10475-10479
 +
| 10480
 +
| 10639
 +
| 10644-10649
 +
|}
 +
 
 +
<br></br>
 +
Run mode explanation:
 +
{| class="wikitable" style="font-weight:bold;"
 +
|-
 +
! Run mode
 +
! StartStop
 +
! Continious
 +
! CycleCentry
 +
! Unknown/Now available
 +
|- style="font-weight:normal;"
 +
| style="font-weight:bold;" | Value (HEX)
 +
| 0
 +
| 1
 +
| 2
 +
| 7
 +
|}
 +
<br></br>
 +
Fuel and Battery state flag explanation:
 +
{| class="wikitable" style="font-weight:bold;"
 +
|-
 +
! Fuel/Battery Flag Status
 +
! Available
 +
! Error
 +
! Alarm
 +
! Digital sensor
 
|- style="font-weight:normal;"
 
|- style="font-weight:normal;"
| style="vertical-align:middle; font-weight:bold;" | AVL ID
+
| style="font-weight:bold;" | Enum (bit field) value
| style="vertical-align:middle;" | 10062
+
| 0
| style="vertical-align:middle;" | 10071
+
| 1
| style="vertical-align:middle;" | 10350
+
| 2
| style="vertical-align:middle;" | 10352
+
| 3
| style="vertical-align:middle;" | 10354
  −
| style="vertical-align:middle;" | 10472
  −
| style="vertical-align:middle;" | 10473
  −
| style="vertical-align:middle;" | 10474
  −
| style="vertical-align:middle;" | 10480
  −
| style="vertical-align:middle;" | 10639
  −
| style="vertical-align:middle;" | 10644-10649
  −
| 10464-10467
  −
| 10468-10471
   
|}
 
|}
 +
 +
==='''Euroscan'''===
 +
To properly use Euroscan with FMX640 these steps must be followed:
 +
*In FMX640 RS232 settings '''Euroscan mode''' is selected and '''Baudrate set to 38400'''
 +
*'''Partner mode enabled''' on Euroscan
 
<br></br>
 
<br></br>
==Configuration==
     −
Make sure the {{{model|}}} device is configured to receive data from “Transcan2 Reefer”, "Touchprint Reefer" or "DataCold Reefer". To do this, enter the configurator window, select the RS232 \ RS485 section displayed in the screenshots below, and configure accordingly (COM1/COM2 Settings, Mode “Transcan2 Reefer”, "Touchprint Reefer" or "DataCold Reefer", Baudrate: Default)
+
[[File:511336 Thermograph data cold colour .png|693x693px]]
 +
 
   −
[[File:Transcan2_Reefer_2021_08_12.png|alt=|frameless|746x746px]][[File:Touchprint_Reefer_2021_08_12.png|alt=|frameless|746x746px]]
+
To enable Partner mode on Euroscan :
 +
# Press and hold the green button for 4 seconds
 +
# Insert password. Default password - 1111
 +
# Press the blue button to open 11 communication settings
 +
# Press the green button to select edit action
 +
# 11.1.0 Com1 Port settings should be opened, then press the green button again
 +
# Then search for Partner protocol and press the green button to accept changes
 +
<br></br>
 +
Important note - RX and TX are inverted via the RS-232 connection. Scheme to properly manage Euroscan  RS232 connection:
 +
Pinout of DataCold600
 +
[[File:517440 DataCold PINOUT.jpg]]
 +
<br></br>
 +
Available parameters (AVL IDs) with Euroscan :
   −
[[File:DataCold Reefer 2021 08 20.png|frameless|739x739px]]
     −
==== DataCold Reefer ====
+
{| class="wikitable" style="font-weight:bold; text-align:center;"
 +
|-
 +
! style="vertical-align:middle;" | External Sensor Temperature 1
 +
! style="vertical-align:middle;" | External Sensor Temperature 2
 +
! style="vertical-align:middle;" | External Sensor Temperature 3
 +
! style="vertical-align:middle;" | External Sensor Temperature 4
 +
! style="vertical-align:middle;" | External Sensor Temperature 5
 +
! style="vertical-align:middle;" | External Sensor Temperature 6
 +
! style="vertical-align:middle;" | Digital Sensor 1
 +
! style="vertical-align:middle;" | Digital Sensor 2
 +
! style="vertical-align:middle;" | Digital Sensor 3
 +
! style="vertical-align:middle;" | Digital Sensor 4
 +
|-
 +
| 484
 +
| 485
 +
| 486
 +
| 487
 +
| 488
 +
| 489
 +
| 10464
 +
| 10465
 +
| 10466
 +
| 10467
 +
|}
    +
==Configuration==
   −
To configure "DataCold Reefer" I/O parameters, please select "Reefer IO":
+
Make sure the {{{model|}}} device is configured to receive data from “Transcan2 Reefer”, "Touchprint Reefer", "Euroscan: or "DataCold Reefer". To do this, enter the configurator window, select the RS232 \ RS485 section displayed in the screenshots below, and configure accordingly (COM1/COM2 Settings, Mode “Transcan2 Reefer”, "Touchprint Reefer", "Euroscan"or "DataCold Reefer", Baudrate: Default)
   −
[[File:Reefer IO settings.png|frameless|1000x1000px]]
+
[[File:RS-232 refer.png]]
 +
==== DataCold Reefer ====
   −
Data sending parameters (AVL ID) used for "DataCold Reefer" are these: 10040 - 10649. For more in-depth information, please refer to '''[[{{{model|}}} Teltonika Data Sending Parameters ID#Freezer_IO|Data Sending Parameters page]].'''
+
To configure "DataCold Reefer" I/O parameters, please select "Reefer IO":
 +
[[File:ReeferIO.png]]
 +
<br></br>
 +
Data sending parameters (AVL ID) used for "DataCold Reefer" are these: 10040 - 10649. For more in-depth information, please refer to '''[[{{{model|}}}_Teltonika_Data_Sending_Parameters_ID#Reefer_IO|Reefer IO data sending parameters]].'''
   −
==== Transcan2 Reefer ====
+
==== TK Transcan2 Reefer ====
 
To configure "Transcan2 Reefer" I/O parameters, please select "TK Transcom IO":
 
To configure "Transcan2 Reefer" I/O parameters, please select "TK Transcom IO":
 +
[[File:TranscanIO.png]]
 +
<br></br>
 +
Data sending parameters (AVL ID) used for "Transcan2
 +
" are these: 10683 - 10694. For more in-depth information, please refer to '''[[{{{model|}}}_Teltonika_Data_Sending_Parameters_ID#TK_Transcan_IO|Transcan IO data sending parameters]]'''
   −
[[File:Transcom IO settings.png|frameless|1000x1000px]]
+
==== Euroscan IO====
 
+
To configure "Euroscan refeer" I/O parameters select "Euroscan IO":
Data sending parameters (AVL ID) used for "Transcan2 Reefer" are these: 10683 - 10694. For more in-depth information, please refer to '''[[{{{model|}}} Teltonika Data Sending Parameters ID#Freezer_IO|Data Sending Parameters page]].'''  
+
[[File:EuroScanIO.png]]
 +
<br></br>
 +
Data sending parameters (AVL ID) used for "Euroscan" are these: 484-489 and 10464-10467. For more in-depth information, please refer to '''[[{{{model|}}}_Teltonika_Data_Sending_Parameters_ID#TK_Euroscan_IO|Euroscan IO data sending parameters]].'''
   −
==== Touchprint Reefer ====
+
==== TK Touchprint/Touchlog I/O ====
 
To configure "Touchprint Reefer" I/O parameters select "TK Touchprint IO":
 
To configure "Touchprint Reefer" I/O parameters select "TK Touchprint IO":
   −
[[File:Touchprint Reefer IO settings.png|frameless|1000x1000px]]
+
[[File:TouchprintIO.png]]
 
+
<br></br>
Data sending parameters (AVL ID) used for "Touchprint Reefer" are these: 10695 - 10703. For more in-depth information, please refer to '''[[{{{model|}}} Teltonika Data Sending Parameters ID#Freezer_IO|Data Sending Parameters page]].'''
+
Data sending parameters (AVL ID) used for "Touchprint Reefer" are these: 10695 - 10703. For more in-depth information, please refer to '''[[{{{model|}}}_Teltonika_Data_Sending_Parameters_ID#TK_Touchprint_IO|Touchprint IO data sending parameters]].'''
  −
 
         
[[Codec#Codec_8_Extended |Codec 8 Extended]] should be selected as the main data protocol in the “Protocol Settings” tab, which is located in the “System” section.
 
[[Codec#Codec_8_Extended |Codec 8 Extended]] should be selected as the main data protocol in the “Protocol Settings” tab, which is located in the “System” section.
   −
[[image:Reefer3.png|center]]
  −
[[Category:{{{model|}}}]]
   
[[Category:{{{model|}}} Manual]]
 
[[Category:{{{model|}}} Manual]]