Changes

no edit summary
Line 60: Line 60:     
==='''Carrier Datacold 600'''===
 
==='''Carrier Datacold 600'''===
[[File:Carrier Datacold 600.png|center|frameless|693x693px]]
+
To properly use DataCold 600 with FMX640 these steps must followed:
Press the green button for 4 seconds.
     −
→ "Enter PIN" is displayed, enter "1111" with the blue button.
+
*'''In FMX640 RS232 settings DataCold mode is selected and Baudrate set to 38400'''
 +
*'''Partner mode enabled on DataCold 600'''
   −
→ Choose Communication Setup menu with the blue button.
+
To enable Partner mode on DataCold 600:
 +
# Press and hold the green button for 4 seconds
 +
# Insert password. Default password - 1111
 +
# Press the blue button to open 11 communication settings
 +
# Press the green button to select edit action
 +
# 11.1.0 Com1 Port settings should be opened, then press the green button again
 +
# Then search for Partner protocol and press the green button to accept changes
   −
→ Configure COM1 or COM2 depending on the connection:
+
Scheme to properly manage DataCold 600 RS232 connection:
   −
"11.1 COM 1 port settings" will be shown on the display.
+
[[File:DataCold600New]]
   −
Select the default value, "UCP protocol" with the yellow or blue button.
+
Available parameters with DataCold 600:
 
+
{| class="wikitable" style="text-align:center;"
Confirm selection with the green button. Press the red button twice to access the
+
|-
 
+
! style="font-weight:bold;" | Parameter name
main menu.
+
! Power mode
 +
! Speed mode
 +
! Ambient Air Temperature
 +
! Alarm level
 +
! Communication state flags
 +
! Manufacturer ID
 +
! Battery State Flags
 +
! Fuel state flags
 +
! Run Mode
 +
! Fridge Error Codes
 +
! Fridge Temperature Probe 1
 +
! Fridge Temperature Probe 2
 +
|-
 +
| style="font-weight:bold;" | AVL ID
 +
| 10062
 +
| 10071
 +
| 10350
 +
| 10352
 +
| 10354
 +
| 10472
 +
| 10473
 +
| 10474
 +
| 10480
 +
| 10639
 +
| 10644
 +
| 10645
 +
|}
    
==Configuration==
 
==Configuration==

Navigation menu