Template:FTXXXX Device Family Parameter list

System parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
138 Uint8 0 0 8 1 – Ignition Movement source
2 – Accelerometer
4 – GNSS
8 - CAN Speed
133 Uint8 0 0 1 0 – GNSS Speed Source
1 – OBD / CAN
106 Uint8 1 0 1 0 – Disable Static navigation
1 – Enable
112 Uint8 1 0 3 1 – Movement Static navigation source
2 – Ignition
3 – Movement and Ignition
107 Uint8 2 0 2 0 – After Position Fix Send/Save records without TS
1 – Always
2 – After Time Sync
108 Uint8 1 0 1 0 – Disable LED Indication
1 – Enable
109 Uint8 10 1 15 0 – Undefined GNSS source
1 – Beidou only
2 – Glonass only
3 – Glonass and Beidou not allowed
4 – Galileo only
5 – Galileo and Beidou
6 – Galileo and Glonass
7 – Galileo, Glonass and Beidou not allowed
8 – Gps only
9 – Gps and Beidou
10 – Gps and Glonass
11 – Gps, Glonass and Beidou not allowed
12 – Gps and Galileo
13 – Gps, Galileo and Beidou
14 – Gps, Galileo and Glonass
15 – Gps, Galileo, Glonass and Beidou and not allowed
110 Uint8 0 0 1 0 – On need Battery charge mode
1 – After ignition on
113 Uint8 0 0 1 0 – Codec 8 Data Protocol
1 – Codec 8 Extended
135 Uint8 0 0 1 0 – DIN2/AIN1 Input mode
1 – Ground Sense
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
102 Uint8 2 0 4 0 – Disable Sleep settings
1 – GPS sleep
2 – Deep sleep
3 – Online Deep sleep
4 – Ultra Deep sleep
6 – Power Off sleep (only for FMB965)
103 Uint16 1 1 3000 Minutes Timeout


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
101 Uint8 4 1 14 1 – DIN 1 Ignition settings
2 – Accelerometer
3 – Digital Input or Accelerometer
4 - Power Voltage
5 - Digital Input or Power Voltage
6 - Accelerometer or Power Voltage
7 – Digital Input, Accelerometer, or Power Voltage
8 - Engine RPM
9 - Digital Input or Engine RPM
10 - Accelerometer or Engine RPM
11 - Digital Input, Accelerometer or Engine RPM
12 - Power Voltage or Engine RPM
13 - Digital Input, Power Voltage or Engine RPM
14 - Accelerometer, Power Voltage or Engine RPM
104 Uint16 30000 0 30000 mV High voltage
105 Uint16 13200 0 29999 mV Low voltage
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
19001 Uint16 5 1 60 Seconds Movement Start Delay
19002 Uint16 60 5 300 Seconds Movement Stop Delay
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
900 Uint8 1 0 3 0 – Gps only Synchronization settings
1 – NITZ and NTP
2 – NTP
3 – NITZ
901 Uint8 0 0 24 Hours NTP Resync
902 Char "avl1.teltonika.lt" 0 55 String NTP server 1
903 Char "pool.ntp.org" 0 55 String NTP server 2
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
169 Uint8 2 0 2 0 – Disabled Accelerometer Auto Calibration
1 – Once
2 – Continuous
170 Uint8 1 0 1 0 Disabled Gravity Filter
1 Enabled

GPRS parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1000 Uint32 300 30 259200 Seconds Open link timeout
1001 Uint16 30 5 300 Seconds Response timeout
1002 Uint8 0 0 1 0 – Newest Sort by
1 – Oldest
1003 Uint16 0 0 300 Seconds Network ping timeout
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2000 Uint8 1 0 1 0 – Disable GPRS context
1 – Enable
2001 Char "" 0 32 String APN
2002 Char "" 0 32 String APN username
2003 Char "" 0 32 String APN password
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2004 Char "" 0 55 String Domain
2005 Uint16 0 0 65535 Number Port
2006 Uint8 1 0 1 0 – TCP Protocol
1 – UDP
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2010 Uint8 0 0 3 0 - Disable Backup Server Mode
1 - Backup
2 - Duplicate
3 - EGTS
2007 Char "" 0 55 String Backup Server Domain
2008 Uint16 0 0 65535 Number Backup Server Port
2009 Uint8 0 0 1 0 - TCP Backup Server Protocol
1 - UDP
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13003 Uint8 1 0 1 0 - Disable FOTA WEB Status
1 – Enable
13000 Char fm.teltonika.lt 0 55 String FOTA WEB Domain
13001 Uint16 5000 0 65535 Number FOTA WEB Port
13002 Uint16 720 30 65535 Number FOTA WEB Period

Tracking settings

Records settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
107 Uint8 2 0 2 0 – After position fix Saving sending mode
1 – Always
2 – After time sync
1002 Uint8 0 0 1 0 – Newest Sort by
1 – Oldest
113 Uint8 1 1 1 1 – Codec 8 Extended
Data Protocol

Records profile settings

On Stop

Home

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10000 Uint16 3600 0 2592000 Min Period
10004 Uint8 1 1 255 Min Saved Records
10005 Uint16 120 0 2592000 Send Period

Roaming

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10100 Uint16 3600 0 2592000 Min Period
10104 Uint8 1 1 255 Min Saved Records
10105 Uint16 0 0 2592000 Send Period

Moving

Home

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10050 Uint16 300 0 2592000 Min Period
10051 Uint16 100 0 65535 Min Distance
10052 Uint8 10 0 180 Min Angle
10053 Uint8 10 0 100 Min Speed Delta
10054 Uint8 1 1 255 Min Saved Records
10055 Uint16 120 0 2592000 Send Period

Roaming

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10150 Uint16 300 0 2592000 Min Period
10151 Uint16 100 0 65535 Min Distance
10152 Uint8 10 0 180 Min Angle
10153 Uint8 10 0 100 Min Speed Delta
10154 Uint8 1 1 255 Min Saved Records
10155 Uint16 0 0 2592000 Send Period

Features

Driving behavior

Overspeeding

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025500 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11104 Uint16 90 0 260 km/h Max speed

Trip

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025000 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11803 Uint8 5 0 255 km/h Start speed
11804 Uint16 60 0 65535 Seconds Ignition OFF timeout

Odometer

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1001600 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11807 Uint32 0 0 4294967 Kilometer Odometer value


Vehicle protection

Unplug Detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025200 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

Other features

Static navigation

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
106 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

Digital output overcurrent recovery

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
350 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

SMS / Call settings

SMS Security

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3004 Char "" 0 5 String Password