Template:FTXXXX Device Family Parameter list

Mobile network

Mobile data settings

SIM 1 Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2001 Char "" 0 32 String APN
2002 Char "" 0 32 String APN username
2003 Char "" 0 32 String APN password
2016 Uint8 1 0 1 0 – PAP GPRS authentication
1 – CHAP

Server Settings

Primary server settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2004 Char "" 0 55 String Domain
2005 Uint16 0 0 65535 Number Port
2006 Uint8 0 0 3 0 – TCP Protocol
1 – UDP

Server communication settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1000 Uint32 300 30 259200 Seconds Open link timeout
1001 Uint16 30 5 300 Seconds Response timeout
1003 Uint16 0 0 300 Seconds Keep-alive

FOTA WEB settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13003 Uint8 1 0 1 0 - Disable FOTA WEB Settings
1 – Enable
13000 Char fm.teltonika.lt 0 55 String Domain
13001 Uint16 5005 0 65535 Number Port
13001 Uint16 5055 0 65535 Number Pinger port

System parameters

Ignition settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
101 Uint8 4 2 7 1 – Digital Input Ignition settings
2 – Power Voltage
3 – Digital Input or Power Voltage
4 - Accelerometer
5 - Digital Input or Accelerometer
6 - Accelerometer or Power Voltage
7 – Digital Input, Accelerometer or Power Voltage
104 Uint16 30000 0 30000 mV High voltage
105 Uint16 13200 0 29999 mV Low voltage

Movement settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
138 Uint8 2 1 15 1 – Accelerometer Movement source
2 – GNSS
3 – Accelerometer or GNSS
4 - Power Voltage
5 - Accelerometer or Power Voltage
6 - GNSS or Power Voltage
7 – Accelerometer, GNSS or Power Voltage
8 – Digital Input
9 – Accelerometer or Digital Input
10 – Digital Input or GNSS
12 – Digital Input or Power Voltage
15 – Accelerometer, GNSS, Power Voltage or Digital Input
139 Uint16 30000 0 30000 mV High voltage
140 Uint16 13200 0 29999 mV Low voltage

GNSS settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
121 Uint8 10 1 15 0 – Undefined GNSS source
1 – BeiDou only
2 – GLONASS only
3 – GLONASS and BeiDou not allowed
4 – Galileo only
5 – Galileo and BeiDou
6 – Galileo and GLONASS
7 – Galileo, GLONASS and BeiDou not allowed
8 – GPS only
9 – GPS and BeiDou
10 – GPS and GLONASS
11 – GPS, GLONASS and BeiDou not allowed
12 – GPS and Galileo
13 – GPS, Galileo and BeiDou
14 – GPS, Galileo and GLONASS
15 – GPS, Galileo, GLONASS and BeiDou

Movement Delay

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11206 Uint16 2 1 60 Seconds Movement Start Delay
11205 Uint16 60 5 300 Seconds Movement Stop Delay

Time synchronization settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
901 Uint8 3 0 24 Hours NTP resync
902 Char "pool.ntp.org" 0 55 String NTP server 1
903 Char "time.nist.gov" 0 55 String NTP server 2

Tracking settings

Records settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
107 Uint8 2 0 2 0 – After position fix Saving sending mode
1 – Always
2 – After time sync
1002 Uint8 0 0 1 0 – Newest Sort by
1 – Oldest
113 Uint8 1 1 1 1 – Codec 8 Extended
Data Protocol

Records profile settings

On Stop

Home

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10000 Uint16 3600 0 2592000 Min Period
10004 Uint8 1 1 255 Min Saved Records
10005 Uint16 120 0 2592000 Send Period

Roaming

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10100 Uint16 3600 0 2592000 Min Period
10104 Uint8 1 1 255 Min Saved Records
10105 Uint16 0 0 2592000 Send Period

Moving

Home

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10050 Uint16 300 0 2592000 Min Period
10051 Uint16 100 0 65535 Min Distance
10052 Uint8 10 0 180 Min Angle
10053 Uint8 10 0 100 Min Speed Delta
10054 Uint8 1 1 255 Min Saved Records
10055 Uint16 120 0 2592000 Send Period

Roaming

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10150 Uint16 300 0 2592000 Min Period
10151 Uint16 100 0 65535 Min Distance
10152 Uint8 10 0 180 Min Angle
10153 Uint8 10 0 100 Min Speed Delta
10154 Uint8 1 1 255 Min Saved Records
10155 Uint16 0 0 2592000 Send Period

Features

Driving behavior

Overspeeding

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025500 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11104 Uint16 90 0 260 km/h Max speed

Trip

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025000 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11803 Uint8 5 0 255 km/h Start speed
11804 Uint16 60 0 65535 Seconds Ignition OFF timeout

Odometer

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1001600 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11807 Uint32 0 0 4294967 Kilometer Odometer value


Vehicle protection

Unplug Detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025200 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

Other features

Static navigation

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
106 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

Digital output overcurrent recovery

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
350 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

SMS / Call settings

SMS Security

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3004 Char "" 0 5 String Password