Difference between revisions of "Template:Teltonika Data Sending Parameters ID"

From Wiki Knowledge Base | Teltonika GPS
Line 4,734: Line 4,734:
 
<span class="mw-collapsible mw-collapsed">{{Template:AVL ID HW list with DIN1}}</span>
 
<span class="mw-collapsible mw-collapsed">{{Template:AVL ID HW list with DIN1}}</span>
 
| style="vertical-align: middle; text-align: center;" |Eventual I/O elements
 
| style="vertical-align: middle; text-align: center;" |Eventual I/O elements
 +
|-
 +
 +
| style="vertical-align: middle; text-align: center;"|396
 +
| style="vertical-align: middle; text-align: center;"|SECO
 +
| style="vertical-align: middle; text-align: center;"|1
 +
| style="vertical-align: middle; text-align: center;"|Unsigned
 +
| style="vertical-align: middle; text-align: center;"|0
 +
| style="vertical-align: middle; text-align: center;"|2
 +
| style="vertical-align: middle; text-align: center;"|-
 +
| style="vertical-align: middle; text-align: center;"|-
 +
| style="vertical-align: middle;"|0 – SECO dout off<br>1 – SECO dout pulsing<br>2 – SECO dout on
 +
| style="vertical-align: middle; text-align: center;" |
 +
<div class="mw-customtoggle-" style="margin:0 auto; vertical-align: middle; text-align: center; overflow:auto;">
 +
FMBXXX
 +
<span class="mw-collapsible mw-collapsed">{{Template:SECO}}</span>
 +
| style="vertical-align: middle; text-align: center;"| Eventual I/O elements
 
|-
 
|-
  
Line 4,929: Line 4,945:
  
 
| style="vertical-align: middle; text-align: center;"| Eventual I/O elements
 
| style="vertical-align: middle; text-align: center;"| Eventual I/O elements
|-
+
 
| style="vertical-align: middle; text-align: center;"|396
 
| style="vertical-align: middle; text-align: center;"|SECO
 
| style="vertical-align: middle; text-align: center;"|1
 
| style="vertical-align: middle; text-align: center;"|Unsigned
 
| style="vertical-align: middle; text-align: center;"|0
 
| style="vertical-align: middle; text-align: center;"|2
 
| style="vertical-align: middle; text-align: center;"|-
 
| style="vertical-align: middle; text-align: center;"|-
 
| style="vertical-align: middle;"|0 – SECO dout off<br>1 – SECO dout pulsing<br>2 – SECO dout on
 
| style="vertical-align: middle; text-align: center;" |
 
<div class="mw-customtoggle-" style="margin:0 auto; vertical-align: middle; text-align: center; overflow:auto;">
 
FMBXXX
 
<span class="mw-collapsible mw-collapsed">{{Template:SECO}}</span>
 
| style="vertical-align: middle; text-align: center;"| Eventual I/O elements
 
|-
 
|- -->
 
 
|}
 
|}
 
<br />
 
<br />

Revision as of 14:15, 22 December 2023

Document updated according firmware FMB.Ver.03.18.18.Rev.50 and newer.

FMB AVL ID's consist of these parameters groups:

Permanent I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
239 Ignition 1 Unsigned 0 1 - -

0 – Ignition Off
1 – Ignition On

Permanent I/O Elements
240 Movement 1 Unsigned 0 1 - -

0 – Movement Off
1 – Movement On

Permanent I/O elements
80 Data Mode 1 Unsigned 0 5 - -

0 – Home On Stop
1 – Home On Moving
2 – Roaming On Stop
3 – Roaming On Moving
4 – Unknown On Stop
5 – Unknown On Moving

Permanent I/O Elements
21 GSM Signal 1 Unsigned 0 5 - -

Value in range 1-5

Permanent I/O Elements
200 Sleep Mode 1 Unsigned 0 4 - -

0 - No Sleep
1 – GPS Sleep
2 – Deep Sleep
3 – Online Sleep
4 - Ultra Sleep

Permanent I/O Elements
69 GNSS Status 1 Unsigned 0 3 - -

0 - GNSS OFF
1 – GNSS ON with fix
2 - GNSS ON without fix
3 - GNSS sleep

Permanent I/O Elements
181 GNSS PDOP 2 Unsigned 0 500 0.1 Coefficient, calculation formula Permanent I/O Elements
182 GNSS HDOP 2 Unsigned 0 500 0.1 Coefficient, calculation formula Permanent I/O Elements
66 External Voltage 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
24 Speed 2 Unsigned 0 350 - km/h

GNSS Speed

Permanent I/O elements
205 GSM Cell ID 2 Unsigned 0 65535 - -

GSM base station ID

Permanent I/O elements
206 GSM Area Code 2 Unsigned 0 65535 - -

Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations.

Permanent I/O elements
67 Battery Voltage 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
68 Battery Current 2 Unsigned 0 65535 0.001 A

Current

Permanent I/O elements
241 Active GSM Operator 4 Unsigned 0 4294967295 - -

Currently used GSM Operator code

Permanent I/O elements
199 Trip Odometer 4 Unsigned 0 2147483647 - m

Trip Odometer value

Permanent I/O elements
16 Total Odometer 4 Unsigned 0 2147483647 - -

Total Odometer value in meters

Permanent I/O elements
1 Digital Input 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
9 Analog Input 1 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements

179 Digital Output 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
12 Fuel Used GPS 4 Unsigned 0 4294967295 0.001 l

Fuel Used

Permanent I/O elements
13 Fuel Rate GPS 2 Unsigned 0 32767 0.01 l/100km

Average Fuel Use

Permanent I/O elements
17 Axis X 2 Signed -8000 8000 - mG

X axis value

Permanent I/O elements
18 Axis Y 2 Signed -8000 8000 - mG

Y axis value

Permanent I/O elements
19 Axis Z 2 Signed -8000 8000 - mG

Z axis value

Permanent I/O elements
11 ICCID1 8 Unsigned 0 0xffffffffffffffff - -

Value of SIM ICCID, MSB

Permanent I/O elements
10 SD Status 1 Unsigned 0 1 - -

0 - not present 1 - present

Permanent I/O elements
2 Digital Input 2 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
3 Digital Input 3 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
6 Analog Input 2 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
180 Digital Output 2 1 Unsigned 0 1 - - Logic 0/1 Permanent I/O elements
72 Dallas Temperature 1 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
73 Dallas Temperature 2 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
74 Dallas Temperature 3 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
75 Dallas Temperature 4 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
76 Dallas Temperature ID 1 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
77 Dallas Temperature ID 2 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
79 Dallas Temperature ID 3 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
71 Dallas Temperature ID 4 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
78 iButton 8 Unsigned 0 0xffffffffffffffff - - iButton ID Permanent I/O elements
207 RFID 8 Unsigned 0 0xffffffffffffffff - - RFID ID

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
201 LLS 1 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS232/RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
202 LLS 1 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS232/RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
203 LLS 2 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
204 LLS 2 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
210 LLS 3 Fuel Level 2 Unsigned -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
211 LLS 3 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
212 LLS 4 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
213 LLS 4 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
214 LLS 5 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
215 LLS 5 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS485

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
15 Eco Score 2 Unsigned 0 65535 0.01 - Average amount of events on some distance Permanent I/O elements
113 Battery Level 1 Unsigned 0 100 - % Battery capacity level Permanent I/O elements
238 User ID 8 Unsigned 0 0xffffffffffffffff - - MAC address of NMEA receiver device connected via Bluetooth Permanent I/O elements
237 Network Type 1 Unsigned 0 1 - - 0 - 3G

1 - GSM
2 - 4G
3 - LTE CAT M1
4 - LTE CAT NB1
99 - Unknown

FM3001
FMU125
FMU126
FMU130
FMC125
FMC130
FMC150
FMM125
FMM130
FMM150
FMC001
FMM001
FMC800
FMM800
FMC880
FMM880
FMM80A

Permanent I/O elements
4 Pulse Counter Din1 4 Unsigned 0 4294967295 - - Counts pulses, count is reset when records are saved Permanent I/O elements
5 Pulse Counter Din2 4 Unsigned 0 4294967295 - - Counts pulses, count is reset when records are saved Permanent I/O elements
263 BT Status 1 Unsigned 0 4 - - 0 - BT is disabled

1 - BT Enabled, not device connected 2 - Device connected, BTv3 Only 3 - Device connected, BLE only 4 - Device connected, BLE + BT

Permanent I/O elements
264 Barcode ID Variable ASCII 0 32 - - Barcode ID
303 Instant Movement 1 Unsigned 0 1 - - Logic: 0/1 returns movement value Permanent I/O elements
327 UL202-02 Sensor Fuel level 2 Signed -150 32767 0.1 mm UL202-02 Sensor Fuel level

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
483 UL202-02 Sensor Status 1 Unsigned 0 255 - - UL202-02 sensor status codes

FMB125
FMB125
FMU125
FMC125
FMM125

Permanent I/O elements
380 Digital output 3 1 Unsigned 0 1 - - Logic: 0/1 Permanent I/O elements
381 Ground Sense 1 Unsigned 0 1 - - Logic: 0/1 FMB130

FMU130
FMC130
FMM130
FMB140

Permanent I/O elements
387 ISO6709 Coordinates 34 HEX 0 0x7fffffffffffffff - - ISO6709 Coordinates

Latitude, Longitude (in Degrees, Minutes and Seconds) and Altitude:

IO value format: ±DDMMSS.SSSS±DDDMMSS.SSSS±AAA.AAA/

Permanent I/O elements
636 UMTS/LTE Cell ID 4 Unsigned 0 0xFFFFFFFF - - Permanent I/O elements
403 Driver Name 35 Unsigned - - - - Driver name extracted from card, displayed without delimiters ($ signs)

FMBXXX FMU126


Permanent I/O elements
404 Driver card license type 1 Unsigned 0 8 - -

None - 0
B.1 license type - 1
B.2 license type - 2
B.3 license type - 3
B.4 license type - 4
T.1 license type - 5
T.2 license type - 6
T.3 license type - 7
T.4 license type - 8

FMBXXX FMU126


Permanent I/O elements
405 Driver Gender 1 Unsigned 0 2 - -

None - 0
Male - 1
Female - 2

FMBXXX FMU126


Permanent I/O elements
406 Driver Card ID 4 Unsigned 0 4294967295 - -

None - 0
Male - 1
Female - 2

FMBXXX FMU126


Permanent I/O elements
407 Driver card expiration date 1 Unsigned 0 9999 - -

FMBXXX FMU126


Permanent I/O elements
408 Driver Card place of issue 4 Unsigned 0 65535 - - Extracted from card

FMBXXX FMU126


Permanent I/O Elements
409 Driver Status Event 1 Unsigned 0 2 - -

Registered - 0
Deregistered - 1
Swapping - 2

FMBXXX FMU126


Permanent I/O elements
329 AIN Speed 2 Unsigned 0 65535 - - MSP500 Permanent I/O elements
500 MSP500 vendor name 40 ASCII 0 40 - - Name of the integrator who installed the device MSP500 Permanent I/O elements
501 MSP500 vehicle number 40 ASCII 0 40 - - Vehicle number on which the device is installed MSP500 Permanent I/O elements
502 MSP500 speed sensor 1 unsigned 0 1 - - Status of the speed sensor MSP500 Permanent I/O elements
637 Wake Reason 1 Unsigned 0 1 - -

True if device was woken by RTC alarm

FMB965

Permanent I/O elements
10800 EYE Temperature 1 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 1 Permanent I/O elements
10801 EYE Temperature 2 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 2 Permanent I/O elements
10802 EYE Temperature 3 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 3 Permanent I/O elements
10803 EYE Temperature 4 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 4 Permanent I/O elements
10804 EYE Humidity 1 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 1 Permanent I/O elements
10805 EYE Humidity 2 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 2 Permanent I/O elements
10806 EYE Humidity 3 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 3 Permanent I/O elements
10807 EYE Humidity 4 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 4 Permanent I/O elements
10808 EYE Magnet 1 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 1 Permanent I/O elements
10809 EYE Magnet 2 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 2 Permanent I/O elements
10810 EYE Magnet 3 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 3 Permanent I/O elements
10811 EYE Magnet 4 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 4 Permanent I/O elements
10812 EYE Movement 1 2 Unsigned 0 0xFFFF - - Movement state measure by EYE Sensor 1 Permanent I/O elements
10813 EYE Movement 2 2 Unsigned 0 0xFFFF - - Movement state measure by EYE Sensor 2 Permanent I/O elements
10814 EYE Movement 3 2 Unsigned 0 0xFFFF - - Movement state measure by EYE Sensor 3 Permanent I/O elements
10815 EYE Movement 4 2 Unsigned 0 0xFFFF - - Movement state measure by EYE Sensor 4 Permanent I/O elements
10816 EYE Pitch 1 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 1 Permanent I/O elements
10817 EYE Pitch 2 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 2 Permanent I/O elements
10818 EYE Pitch 3 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 3 Permanent I/O elements
10819 EYE Pitch 4 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 4 Permanent I/O elements
10820 EYE Low Battery 1 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 1 Permanent I/O elements
10821 EYE Low Battery 2 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 2 Permanent I/O elements
10822 EYE Low Battery 3 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 3 Permanent I/O elements
10823 EYE Low Battery 4 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 4 Permanent I/O elements
10824 EYE Battery Voltage 1 1 Unsigned 0 0xFF - - Battery Voltage of EYE Sensor 1 Permanent I/O elements
10825 EYE Battery Voltage 2 1 Unsigned 0 0xFF - - Battery Voltage of EYE Sensor 2 Permanent I/O elements
10826 EYE Battery Voltage 3 1 Unsigned 0 0xFF - - Battery Voltage of EYE Sensor 3 Permanent I/O elements
10827 EYE Battery Voltage 4 1 Unsigned 0 0xFF - - Battery Voltage of EYE Sensor 4 Permanent I/O elements
10832 EYE Roll 1 2 Signed -180 180 - - Roll angle measured by EYE Sensor 1 Permanent I/O elements
10833 EYE Roll 2 2 Signed -180 180 - - Roll angle measured by EYE Sensor 2 Permanent I/O elements
10834 EYE Roll 3 2 Signed -180 180 - - Roll angle measured by EYE Sensor 3 Permanent I/O elements
10835 EYE Roll 4 2 Signed -180 180 - - Roll angle measured by EYE Sensor 4 Permanent I/O elements
10836 EYE Movement count 1 2 Unsigned 0 32767 - - Movement count measure by EYE Sensor 1 Permanent I/O elements
10837 EYE Movement count 2 2 Unsigned 0 32767 - - Movement count measure by EYE Sensor 2 Permanent I/O elements
10838 EYE Movement count 3 2 Unsigned 0 32767 - - Movement count measure by EYE Sensor 3 Permanent I/O elements
10839 EYE Movement count 4 2 Unsigned 0 32767 - - Movement count measure by EYE Sensor 4 Permanent I/O elements
10840 EYE Magnet count 1 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 1 Permanent I/O elements
10841 EYE Magnet count 2 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 2 Permanent I/O elements
10842 EYE Magnet count 3 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 3 Permanent I/O elements
10843 EYE Magnet count 4 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 4 Permanent I/O elements
383 AXL Calibration Status 1 Unsigned 0 3 - - Shows calibration status: 0- no calibration, 1- calibrated, 2- not configured, 3- fully calibrated Permanent I/O elements




Eventual I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
155 Geofence zone 01 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
156 Geofence zone 02 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
157 Geofence zone 03 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
158 Geofence zone 04 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
159 Geofence zone 05 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
61 Geofence zone 06 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
62 Geofence zone 07 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
63 Geofence zone 08 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
64 Geofence zone 09 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
65 Geofence zone 10 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
70 Geofence zone 11 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
88 Geofence zone 12 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
91 Geofence zone 13 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
92 Geofence zone 14 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
93 Geofence zone 15 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
94 Geofence zone 16 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
95 Geofence zone 17 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
96 Geofence zone 18 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
97 Geofence zone 19 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
98 Geofence zone 20 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
99 Geofence zone 21 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
153 Geofence zone 22 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
154 Geofence zone 23 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
190 Geofence zone 24 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
191 Geofence zone 25 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
192 Geofence zone 26 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
193 Geofence zone 27 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
194 Geofence zone 28 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
195 Geofence zone 29 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
196 Geofence zone 30 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
197 Geofence zone 31 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
198 Geofence zone 32 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
208 Geofence zone 33 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
209 Geofence zone 34 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
216 Geofence zone 35 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
217 Geofence zone 36 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
218 Geofence zone 37 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
219 Geofence zone 38 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
220 Geofence zone 39 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
221 Geofence zone 40 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
222 Geofence zone 41 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
223 Geofence zone 42 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
224 Geofence zone 43 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
225 Geofence zone 44 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
226 Geofence zone 45 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
227 Geofence zone 46 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
228 Geofence zone 47 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
229 Geofence zone 48 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
230 Geofence zone 49 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
231 Geofence zone 50 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
175 Auto Geofence 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

Eventual I/O elements
250 Trip 1 Unsigned 0 1 - -

0 – trip stop
1 – trip start
From 01.00.24 fw version available with BT app new values:
2 – Business Status
3 – Private Status
4-9 – Custom Statuses

Eventual I/O elements
255 Over Speeding 1 Unsigned 0 255 - km/h

At over speeding start km/h, at over speeding end km/h

Eventual I/O elements
257 Crash trace data Variable HEX 0 1200 - - Crash trace data Eventual I/O elements
285 Blood alcohol content 2 Unsigned 0 9999 - - Alcohol content in blood in perlims and mode. First 14 bits from MSB are perlims multiplied by 1000 and last to bits are 0 - Passive test, 1 Active test, 2 and 3 are reserved. FMB125 Eventual I/O elements
251 Idling 1 Unsigned 0 1 - -

0 – moving
1 – idling

Eventual I/O elements
253 Green driving type 1 Unsigned 1 3 - -

1 – harsh acceleration
2 – harsh braking
3 – harsh cornering

Eventual I/O elements
246 Towing 1 Unsigned 0 1 - -

0 – steady
1 – towing

Eventual I/O elements
252 Unplug 1 Unsigned 0 1 - -

0 – battery present
1 – battery unplugged

Eventual I/O elements
247 Crash detection 1 Unsigned 1 6 - -

1 – real crash detected (device is calibrated)
2 – limited crash trace (device not calibrated)
3 - limited crash trace (device is calibrated)
4 - full crash trace (device not calibrated)
5 - full crash trace (device is calibrated)
6 - real crash detected (device not calibrated)

Eventual I/O elements
248 Immobilizer 1 Unsigned 0 2 - -

0 – iButton not connected
1 – iButton connected (Immobilizer)
2 – iButton connected (Authorized Driving)

Eventual I/O elements
254 Green Driving Value 1 Unsigned 0 255 acc and braking: 0.01 G
or
rad
Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g). If Green driving source is „GPS“ – harsh cornering value is rad/s*100. If source is „Accelerometer“ – g*100. Eventual I/O elements
249 Jamming 1 Unsigned 0 1 - -

0 – jamming stop
1 – jamming start

Eventual I/O elements
14 ICCID2 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - -

Value of SIM ICCID, LSB

Eventual I/O elements
243 Green driving event duration 2 Unsigned 0 65535 - ms

Duration of event that did generate Green driving

Eventual I/O elements
236 Alarm 1 Unsigned 0 1 - -

0 – Reserved
1 – Alarm event occured

Eventual I/O elements
258 EcoMaximum 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - -

Element stores maximum accelerometer values in mg on all axis during Eco driving event
8 Bytes:
2B Zeros 2B - X axis 2B - Y axis 2B - Z axis

FMT100

Eventual I/O elements
259 EcoAverage 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - -

Element stores average accelerometer values in mg on all axis during Eco driving event
8 Bytes:
2B Zeros 2B - X axis 2B - Y axis 2B - Z axis

FMT100

Eventual I/O elements
260 EcoDuration 2 Unsigned 0 65535 - ms

Duration of Eco driving event in miliseconds

FMT100

Eventual I/O elements
283 Driving State 1 Unsigned 0 3 - -

1 - Ignition ON
2 - Driving
3 - Ignition OFF

FMT100

Eventual I/O elements
284 Driving Records 2 Unsigned 0 65535 - -

Number of Records between Ignition ON and Ignition OFF

FMT100

Eventual I/O elements
391 Private mode 1 Unsigned 0 255 - - Private mode state

0 - Private mode off 1 - Private mode on

Eventual I/O elements
317 Crash event counter 1 Unsigned 0 255 - - Connects trace with specific eventual crash record Eventual I/O elements
449 Ignition On Counter 4 Unsigned 0 2147483647 - s

Duration in seconds which is counted while Ignition state is On

Eventual I/O elements
396 SECO 1 Unsigned 0 2 - - 0 – SECO dout off
1 – SECO dout pulsing
2 – SECO dout on
Eventual I/O elements