Property ID in AVL packet Property name Bytes Type Value range Multiplier Units Description HW Support Parameter group
Min Max
239 Ignition 1 Unsigned 0 1 - - 0 – Ignition Off FMB001 ,FMB010 ,FMB100 ,FMB110 ,FMB120 ,FMB122 ,FMB125 ,FMB900 ,FMB920 ,FMB962 ,FMB964 ,FM3001,FM3010 Permanent I/O elements
1 – Ignition On
240 Movement 1 Unsigned 0 1 - - 0 – Movement Off FMB001 ,FMB010 ,FMB100 ,FMB110 ,FMB120 ,FMB122 ,FMB125 ,FMB900 ,FMB920 ,FMB962 ,FMB964 ,FM3001,FM3010,TMT250 Permanent I/O elements
1 – Movement On
80 Data Mode 1 Unsigned 0 5 - - 0 – Home On Stop FMB001 ,FMB010 ,FMB100 ,FMB110 ,FMB120 ,FMB122 ,FMB125 ,FMB900 ,FMB920 ,FMB962 ,FMB964 ,FM3001,FM3010,TMT250 Permanent I/O elements
1 – Home On Moving
2 – Roaming On Stop
3 – Roaming On Moving
4 – Unknown On Stop
5 – Unknown On Moving