FMC650 SMS/Call settings

From Wiki Knowledge Base | Teltonika GPS
Revision as of 11:25, 1 February 2022 by Arnas.Zeb (talk | contribs) (Created page with "{{Template:FMC640_SMS/Call_settings|model=FMC650}} Category:FMC650 Configuration")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > Professional Trackers > FMC650 > FMC650 Configuration > FMC650 SMS/Call settings

Essential fields in SMS/Call settings are Login and Password. The login and password are used with every SMS sent to FMC650. If login and password are not set, in every SMS sent to FMC650 device two spaces before command have to be used "<space><space><command>".
Command structure with set login and password:
"<login><space><password><space><command>", for example: "asd 123 getgps"
Phone numbers have to be written in international standard, using "+" is optional but not necessary (in both cases number will be recognized, but when number is without "+" symbol, IDD Prefix will not be generated, which depends on location of the phone). If no numbers are entered, configuration and sending commands over SMS are allowed from all GSM numbers.
SMS data sending settings allow sending AVL data using binary SMS. AVL data will be sent by SMS only when there is no GPRS connection. This setting does not affect replies to SMS request messages – answers are always sent back to the sender's telephone number.

Fmc650 screen.png
Bw nb.png Please do not set Data Send Number to some cell phone number, because it will not understand binary SMS. When sending a binary SMS to a phone number, which is a server phone number, the server can interpret and understand binary code, so the data can be read and you can view it on the server.
Bw nb.png SMS login and password and authorized numbers list are used to protect FMC650 module from unauthorized access. Module accepts messages only from a list of authorized numbers and with proper module login and password. Phone numbers have to be written in international standard using "+" or without using it (in both cases the number will be recognized). If no authorized numbers are entered, module accepts messages from all numbers.