Green Drivind scenario

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1600 U8 0 0 3 0 – disable Green Driving scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario
1602 Float 0.25 0.25 0.85 G Max Acceleration Force
1603 Float 0.25 0.35 0.85 G Max Braking Force
1604 U16 0.3 0.1 1.0 rad/second Max Cornering Force
1605 U16 0 0 260 km/h Max allowed Speed
1909 U8 0 0 1 0 – GPS Green Driving Source
1 – Accelerometer

Over Speeding

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1601 U8 0 0 3 0 – disable OverSpeeding scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario

Jamming

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1606 U8 0 0 3 0 – disable Jamming detection scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario

Immobilizer

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1607 U8 0 0 3 0 – disable Immobilizer scenario
1 – Dout not control scenario
2 – Dout1 controls scenario
3 – Dout2 controls scenario
1609 U8 30 5 65535 seconds Immobilizer ignition timeout
1608 U8 0 0 1 0 – disable iButton list checking scenario
1 – enabled

Excessive Idling detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1610 U8 0 0 1 0 – disable Excessive Idling detection
1 – enable
1611 U8 0 0 255 seconds Time to stationary
1612 U8 0 0 255 seconds Time to movement

Trip

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1280 U8 0 0 1 0 – disable Trip start/stop detection
1 – enable
1281 U8 5 0 255 km/h Start Speed
1282 U16 60 0 65535 seconds Ignition Off Timeout
1283 U8 0 0 2 0 – Between records Trip distance mode
1 – Continuous trip
1 – Continuous
1284 Uint8 - 0 1 0 – disable Enable odometer value setting
1 – enable
1285 U32 1 0 4294967295 meters Continuous odometer value
1286 U8 0 0 1 0 – disable Name
1 – enable

Geofencing

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1020 U32 1000 0 1000000 meters Frame border
Geofence Zone #1 parameters
1030 U8 0 0 1 0 – circle Geofence Zone #1 Shape
1 – rectangle
1031 U8 0 0 3 0 – disabled Geofence Zone #1 Priority
1 – low
2 – high
3 – panic
1032 U8 0 0 2 0 – On exiting zone Geofence Zone #1 Generate Event
1 – On entering zone
2 – On both
1033 Float - -180 180 number Geofence Zone #1 Longitude (X1)
1034 Float - -90 90 number Geofence Zone #1 Latitude (Y1)
if parameter Geofence Zone #1 Shape (1030) - rectangle
1035 Float 0 -180 180 number Geofence Zone #1 Longitude (X2)
1036 Float 0 -90 90 number Geofence Zone #1 Latitude (Y2)
if parameter Geofence Zone #1 Shape (1030) - circle
1035 Float 0 0 1000000 meter Geofence Zone #1 radius
1036 If shape is circle, parameter ID = 1036 is not used.
Geofence Zone #2 parameters
1040 U8 0 0 1 0 – circle Geofence Zone #2 Shape
1 – rectangle
1041 U8 0 0 3 0 – disabled Geofence Zone #2 Priority
1 – low
2 – high
3 – panic
1042 U8 0 0 2 0 – On exiting zone Geofence Zone #2 Generate Event
1 – On entering zone
2 – On both
1043 Float - -180 180 number Geofence Zone #2 Longitude (X1)
1044 Float - -90 90 number Geofence Zone #2 Latitude (Y1)
if parameter Geofence Zone #2 Shape (1040) - rectangle
1045 Float 0 -180 180 number Geofence Zone #2 Longitude (X2)
1046 Float 0 -90 90 number Geofence Zone #2 Latitude (Y2)
if parameter Geofence Zone #2 Shape (1040) - circle
1045 Float 0 0 1000000 meter Geofence Zone #2 radius
1046 If shape is circle, parameter ID = 1046 is not used.
Geofence Zone #3 parameters
1050 U8 0 0 1 0 – circle Geofence Zone #3 Shape
1 – rectangle
1051 U8 0 0 3 0 – disabled Geofence Zone #3 Priority
1 – low
2 – high
3 – panic
1052 U8 0 0 2 0 – On exiting zone Geofence Zone #3 Generate Event
1 – On entering zone
2 – On both
1053 Float - -180 180 number Geofence Zone #3 Longitude (X1)
1054 Float - -90 90 number Geofence Zone #3 Latitude (Y1)
if parameter Geofence Zone #3 Shape (1050) - rectangle
1055 Float 0 -180 180 number Geofence Zone #3 Longitude (X2)
1056 Float 0 -90 90 number Geofence Zone #3 Latitude (Y2)
if parameter Geofence Zone #3 Shape (1050) - circle
1055 Float 0 0 1000000 meter Geofence Zone #3 radius
1056 If shape is circle, parameter ID = 1056 is not used.
Geofence Zone #4 parameters
1060 U8 0 0 1 0 – circle Geofence Zone #4 Shape
1 – rectangle
1061 U8 0 0 3 0 – disabled Geofence Zone #4 Priority
1 – low
2 – high
3 – panic
1062 U8 0 0 2 0 – On exiting zone Geofence Zone #4 Generate Event
1 – On entering zone
2 – On both
1063 Float - -180 180 number Geofence Zone #4 Longitude (X1)
1064 Float - -90 90 number Geofence Zone #4 Latitude (Y1)
if parameter Geofence Zone #4 Shape (1060) - rectangle
1065 Float 0 -180 180 number Geofence Zone #4 Longitude (X2)
1066 Float 0 -90 90 number Geofence Zone #4 Latitude (Y2)
if parameter Geofence Zone #4 Shape (1060) - circle
1065 Float 0 0 1000000 meter Geofence Zone #4 radius
1066 If shape is circle, parameter ID = 1066 is not used.
Geofence Zone #5 parameters
1070 U8 0 0 1 0 – circle Geofence Zone #5 Shape
1 – rectangle
1071 U8 0 0 3 0 – disabled Geofence Zone #5 Priority
1 – low
2 – high
3 – panic
1072 U8 0 0 2 0 – On exiting zone Geofence Zone #5 Generate Event
1 – On entering zone
2 – On both
1073 Float - -180 180 number Geofence Zone #5 Longitude (X1)
1074 Float - -90 90 number Geofence Zone #5 Latitude (Y1)
if parameter Geofence Zone #5 Shape (1070) - rectangle
1075 Float 0 -180 180 number Geofence Zone #5 Longitude (X2)
1076 Float 0 -90 90 number Geofence Zone #5 Latitude (Y2)
if parameter Geofence Zone #5 Shape (1070) - circle
1075 Float 0 0 1000000 meter Geofence Zone #5 radius
1076 If shape is circle, parameter ID = 1076 is not used.