Template:FM36 System Parameters

From Wiki Knowledge Base | Teltonika GPS
Revision as of 08:24, 4 June 2018 by Simkunas.ma (talk | contribs)

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1000 U8 0 0 2 0 – Disabled Sleep Settings
1 – GPS Sleep
2 – Deep Sleep
200 U8 1 1 3000 - Sleep Timeout
1001 U8 0 0 1 0 - 10V Analog Input value range
1 – 30V
1002 U8 1 0 3 0 - ignition Stop Detection Source
1 - Msensor
2 - GPS
3 - ignition + Msensor
1003 U8 0 0 1 0 - Disabled Static Navigation
1 – Enabled
1004 0 0 2 0 – Power voltage Ignition Source
1 – Digital input 1
2 – Msensor
1005 30000 mV 13000 mV 30000 mV High Voltage Level
1006 13000 mV 0 30000 mV Low Voltage Level
1008 0 0 1 0 - Manual Ignition Detection
1 – Automatic
1009 U8 10 0 65535 Ignition Detection Timeout
1007 U8 60 0 65535 GNSS FIX Timeout for Time Synchronization via NTP
201 U8 0 0 1 0 - Disabled Saving/Sending without time synchronization
1 – Enabled
202 U8 0 0 2 0 – GNSS (all available) Satellite System
1 – GPS
2 – GLONASS