Difference between revisions of "Template:FMB1 Electrical characteristics"

From Wiki Knowledge Base | Teltonika GPS
Line 58: Line 58:
 
<tr>
 
<tr>
 
         <td style="text-align:left">Input resistance (DIN2)</td>
 
         <td style="text-align:left">Input resistance (DIN2)</td>
         <td style="width: 8%; text-align:left; vertical-align:middle">51.7</td>
+
         <td style="width: 8%; text-align:left; vertical-align:middle">{{{input_resistence_din2|51.7}}}</td>
 
         <td style="width: 8%; text-align:left"></td>
 
         <td style="width: 8%; text-align:left"></td>
 
         <td style="width: 8%; text-align:left"></td>
 
         <td style="width: 8%; text-align:left"></td>
Line 65: Line 65:
 
<tr>
 
<tr>
 
         <td style="text-align:left">Input resistance (DIN3)</td>
 
         <td style="text-align:left">Input resistance (DIN3)</td>
         <td style="width: 8%; text-align:left; vertical-align:middle">47</td>
+
         <td style="width: 8%; text-align:left; vertical-align:middle">{{{input_resistence_din3|47}}}</td>
 
         <td style="width: 8%; text-align:left"></td>
 
         <td style="width: 8%; text-align:left"></td>
 
         <td style="width: 8%; text-align:left"></td>
 
         <td style="width: 8%; text-align:left"></td>

Revision as of 10:20, 6 June 2019

Electrical characteristics


Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage:
Supply Voltage
(Recommended Operating Conditions)
+10 +30 V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF) 120 µA
Drain current
(Digital Output ON, Recommended Operating Conditions)
0.1 0.5 A
Static Drain-Source resistance
(Digital Output ON)
400 600
Digital Input:
Input resistance (DIN1) 47
Input resistance (DIN2) 51.7
Input resistance (DIN3) 47
Input voltage
(Recommended Operating Conditions)
0 Supply voltage V
Input Voltage threshold (DIN1) 7.5 V
Input Voltage threshold (DIN2) 2.5 V
Input Voltage threshold (DIN3) 2.5 V
Analog Input:
Input voltage
(Recommended Operating Conditions), Range 1
0 +10 V
Input resistance, Range 1 150
Measurement error on 12V, Range 1 3 %
Additional error on 12 V, Range 1 360 mV
Measurement error on 30 V, Range 1 3 %
Additional error on 30 V, Range 1 900 mV
Input Voltage
(Recommended Operating Conditions), Range 2
0 +30 V
Input resistance, Range 2 150
Measurement error on 12V, Range 2 3 %
Additional error on 12 V, Range 2 360 mV
Measurement error on 30 V, Range 2 3 %
Additional error on 30 V, Range 2 900 mV
Output Supply Voltage 1-Wire:
Supply voltage +4.5 +4.7 V
Output inner resistance 7 Ω
Output current (Uout > 3.0 V) 30 mA
Short circuit current (Uout = 0) 75 mA


Alert.png
Analog Input error margin can increase if temperature varies.

Absolute maximum ratings

Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage
(Absolute Maximum Ratings)
-32 +32 V
Drain-Source clamp threshold voltage
(Absolute Maximum Ratings), (Idrain = 2 mA)
+36 V
Digital Input Voltage
(Absolute Maximum Ratings)
-32 +32 V
Analog Input Voltage
(Absolute Maximum Ratings)
-32 +32 V