Template:FMB9 Electrical characteristics

From Wiki Knowledge Base | Teltonika GPS

Electrical characteristics

Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage:
Supply Voltage
(Recommended Operating Conditions)
6 30 V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF) 120 µA
Drain current
(Digital Output ON, Recommended Operating Conditions)
3.3 mA
Digital Input: 300
Digital Output (Open Drain grade):
Input resistance (DIN1) 47
Input voltage
(Recommended Operating Conditions)
0 Supply voltage V
Input Voltage threshold (DIN1) 2.5 V
Analog Input:
Input voltage
(Recommended Operating Conditions)
0 30 V
Input resistance 150
Measurement error on 12 V 3 %
Additional error on 12 V 360 mV
Measurement error on 30 V 3 %
Additional error on 30 V 900 mV
Bw nb.png Analog Input error margin can increase if temperature varies.

Absolute maximum ratings

Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage (Absolute Maximum Ratings) -32 +32 V
Drain-Source clamp threshold voltage (Absolute Maximum Ratings), (Idrain = 2 mA) +36 V
Digital Input Voltage (Absolute Maximum Ratings) -32 +32 V
Analog Input Voltage (Absolute Maximum Ratings) -32 +32 V