System parameters
Parameter ID | Parameter Type | Recomended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1002 | Uint8 | - | 0 | 2 | 0 – Ignition | Stop Detection Source |
1 – Movement sensor | ||||||
2 – GPS | ||||||
1003 | Uint8 | 1 | 0 | 1 | 0 – Disable | Static navigation |
1 – Enable | ||||||
1004 | Uint8 | - | 0 | 2 | 0 – Power voltage | Ignition source |
1 – Digital input 1 | ||||||
1 – Movement | ||||||
1005 | Uint16 | - | 0 | 30000 | Voltage | Power Voltage High Level |
1006 | Uint16 | - | 0 | 30000 | Voltage | Power Voltage Low Level |
1920 | Uint8 | - | 0 | 1 | 0 – Manual | Ignition detection (Power voltage) |
1 – Auto | ||||||
1921 | Uint8 | 10 | 0 | 65536 | Seconds | Ignition detection timeout |
201 | Uint8 | 1 | 0 | 2 | 0 – after position fix | Records Saving/Sending |
1 – always | ||||||
2 – after time sync | ||||||
202 | Uint8 | 0 | 0 | 2 | 0 – GNSS (all available) | GNSS System |
1 – GPS only | ||||||
2 – GLONASS only | ||||||
1007 | Uint32 | - | 1 | 259200 | Seconds | GNSS Fix Timeout |
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1000 | Uint8 | - | 0 | 2 | 0 – Disable | Sleep settings |
1 – Sleep | ||||||
2 – Deep sleep | ||||||
200 | Uint8 | - | 1 | 3000 | Minutes | Timeout |
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1001 | Uint8 | - | 0 | 1 | 0 – 0...10V | Analog Input value range |
1 – 1...30V |
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1008 | Uint8 | 1 | 0 | 1 | 0 - disabled | NTP Time Synchronization |
1 – enabled |
Records parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1010 | Uint8 | - | 0 | 1 | 0 - From oldest | Sorting |
1 - From Newest | ||||||
1011 | Uint32 | - | 0 | 259200 | Seconds | Active Data Link Timeout |
1012 | Uint8 | - | 0 | 300 | Seconds | Server Response Timeout |
GSM parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1240 | Uint8 | - | 0 | 1 | 0 – Disable | GPRS content activation |
1 – Enable | ||||||
1242 | Char | - | 0 | 32 | String | APN name |
1243 | Char | - | 0 | 30 | String | APN username |
1244 | Char | - | 0 | 30 | String | APN password |
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1245 | Char | - | 0 | 31 | String | Domain |
1246 | Uint16 | - | 0 | 65535 | Number | Target Server Port |
1247 | Uint8 | - | 0 | 1 | 0 – TCP | Protocol |
1 – UDP | ||||||
1248 | Uint8 | - | 0 | 1 | 0 – Not Allowed | Always online |
1 – Allowed |
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1252 | Char | - | 0 | 5 | String | SMS Login |
1253 | Char | - | 0 | 5 | String | SMS password |
1250 | Char | - | 0 | 1 | 0 - Not Allowed | SMS data sending settings |
1 - Allowed | ||||||
1273 | Uint32 | Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF | - | - | Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. | GPRS Week Time |
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1260-1269 | Char | - | 1 digit | 16 digits | String | Authorized phone numbers |
150-159 | Char | - | 1 digit | 16 digits | String | SMS Event PreDefined Numbers |
1271 X | u32 | X defines starting position that is changed: If X is from 0 to 49, X means index of operator code which has to be configured. | 0 digit | 7 digits | String | Operator list |
1272 X | u32 | X defines starting position that is changed: If X is from 0 to 49, X means index of operator code which has to be configured. | 0 digit | 7 digits | String | Operator Black list |
Data Acquisition Modes parameters
Home Network GSM operator code "Vehicle on STOP" parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1540 | Uint32 | - | 0 | 2592000 | Seconds | Min Period |
1543 | Uint8 | 1 | 1 | 225 | Records | Min Saved Records |
1544 | Uint32 | - | 0 | 2592000 | Seconds | Send period |
1545 | Uint32 | Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF | - | - | Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. | GPRS Week Time |
Home Network GSM operator code "Vehicle on MOVING" parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1550 | Uint32 | - | 0 | 2592000 | Seconds | Min Period |
1551 | Uint32 | - | 0 | 65535 | Meters | Min distance |
1552 | Uint16 | 0 | 1 | 160 | Angle | Min angle |
1553 | Uint16 | 1 | 1 | 255 | Records | Min Saved Records |
1554 | Uint32 | - | 0 | 2592000 | Seconds | Send period |
1555 | Uint32 | Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF | - | - | Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. | GPRS Week Time |
1556 | Uint16 | - | 0 | 255 | km/h | Min Speed |
1557 | Uint8 | - | 0 | 1 | 0- GPS | Min Speed Source |
1- LVCAN |
Roaming Network GSM operator code "Vehicle on STOP" parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1560 | Uint32 | - | 0 | 2592000 | Seconds | Min Period |
1563 | Uint8 | 1 | 1 | 225 | Records | Min Saved Records |
1564 | Uint32 | - | 0 | 2592000 | Seconds | Send period |
1565 | Uint32 | Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF | - | - | Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. | GPRS Week Time |
Roaming Network GSM operator code "Vehicle on MOVING" parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1570 | Uint32 | - | 0 | 2592000 | Seconds | Min Period |
1571 | Uint32 | - | 0 | 65535 | Meters | Min distance |
1572 | Uint16 | 0 | 1 | 160 | Angle | Min angle |
1573 | Uint16 | 1 | 1 | 255 | Records | Min Saved Records |
1574 | Uint32 | - | 0 | 2592000 | Seconds | Send period |
1575 | Uint32 | Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF | - | - | Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. | GPRS Week Time |
1576 | Uint16 | - | 0 | 255 | km/h | Min Speed |
1577 | Uint8 | - | 0 | 1 | 0- GPS | Min Speed Source |
1- LVCAN |
Unknown Network GSM operator code "Vehicle on STOP" parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1580 | Uint32 | - | 0 | 2592000 | Seconds | Min Period |
1583 | Uint8 | 1 | 1 | 225 | Records | Min Saved Records |
1584 | Uint32 | - | 0 | 2592000 | Seconds | Send period |
1585 | Uint32 | Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF | - | - | Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. | GPRS Week Time |
Unknown Network GSM operator code "Vehicle on MOVING" parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1590 | Uint32 | - | 0 | 2592000 | Seconds | Min Period |
1591 | Uint32 | - | 0 | 65535 | Meters | Min distance |
1592 | Uint16 | 0 | 1 | 160 | Angle | Min angle |
1593 | Uint16 | 1 | 1 | 255 | Records | Min Saved Records |
1594 | Uint32 | - | 0 | 2592000 | Seconds | Send period |
1595 | Uint32 | Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF | - | - | Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. | GPRS Week Time |
1596 | Uint16 | - | 0 | 255 | km/h | Min Speed |
1597 | Uint8 | - | 0 | 1 | 0- GPS | Min Speed Source |
1- LVCAN |
Features parameters
Green driving parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1890 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1891 | Uint8 | - | 0 | 2 | 0 - disable | Digital Output Control |
1 - DOUT1 | ||||||
2 - DOUT2 | ||||||
1909 | Uint8 | - | 0 | 1 | 0 - GPS | Source |
1 - Accelerometer | ||||||
1892 | Float | 0.25 | 0.25 | 0.85 | mG | Max Acceleration Force |
1893 | Float | 0.35 | 0.25 | 0.85 | mG | Max Braking Force |
1894 | Float | 0.2 | 0.1 | 1.0 | mG | Max Cornering Force |
Overspeeding scenario parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1895 | Uint8 | 0 | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1896 | Uint8 | - | 0 | 2 | 0 – None | Digital Output control |
1 – DOUT 1 | ||||||
2 – DOUT 2 | ||||||
1897 | Uint16 | - | 0 | 260 | km/h | Max speed |
Jamming scenario parameters
Parameter ID | Parameter Type | Recommended Value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1898 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1899 | Uint8 | - | 0 | 2 | 0 – None | Digital Output control |
1 – DOUT1 | ||||||
2 – DOUT2 | ||||||
1900 | Uint8 | - | 0 | 2 | 0 – Low sensitivity (50 RSSI) | Jamming sensitivity |
1 – Medium sensitivity (30 RSSI) | ||||||
2 – High sensitivity (10 RSSI) | ||||||
1901 | Uint16 | 60 | 0 | 65535 | Seconds | Jamming Timeout |
1902 | Uint16 | 0 | 0 | 65535 | Seconds | Jamming Pulse Duration |
Immobilizer scenario parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1903 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1904 | Uint8 | - | 0 | 2 | 0 – Disable | Digital Output Control |
1 – DOUT1 | ||||||
2 – DOUT2 | ||||||
1905 | Uint8 | - | 0 | 1 | 0 – Disable | iButton list checking |
1 – Enable | ||||||
1906 | Uint16 | 30 | 5 | 65353 | Seconds | Ignition Off Timeout |
iButton read notification
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1907 | Uint8 | - | 0 | 1 | 0 - Disabled | iButton detect |
1 - Enabled | ||||||
1908 | Uint8_t | 0 | 0 | 1 | 0 - Disabled | Digital Output Control |
1 - DOUT1 | ||||||
2 - DOUT2 |
Trip scenario parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1280 | Uint8 | - | 0 | 1 | 0 – Disable | Scenario settings |
1 – Enable | ||||||
1281 | Uint8 | - | 0 | 255 | km/h | Start speed |
1282 | Uint16 | - | 0 | 65535 | Seconds | Ignition off timeout |
1283 | Uint8 | - | 0 | 1 | 0 – Not | Continuous distance counting |
1 – Continuous | ||||||
1284 | Uint8 | - | 0 | 1 | 0 – Disable | Remember iButton ID |
1 – Enable | ||||||
1285 | Uint8 | - | 0 | - | Meters | Odometer Value |
AutoGeofencing scenario parameters
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1101 | Uint8 | 1 | 0 | 1 | 0 – Disable | Scenario Settings |
1 – Enable | ||||||
1102 | Uint16 | 60 | 0 | 65535 | 0 – Disable | Activation Timeout |
1100 | Uint8 | - | 0 | 1 | 0 – Ignition | Deactivation Source |
1 – Enable | ||||||
1103 | Uint8 | 1 | 0 | 1 | 0 - Low | AutoGeofence event priority |
1 - hight | ||||||
1104 | Uint8 | 2 | 0 | 3 | 0 - No Event | AutoGeofence event generating |
1 - On entering zone | ||||||
2 - On exiting zone | ||||||
3 - On both | ||||||
1105 | Uint32 | 100 | 0 | 1000000 | Meters | Radius |
iButton list
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
3500-3999 | Uint64 | - | 0 | FFFFFFFF FFFFFFFF | 0 – iButton ID | iButton list |
Manual Geofence
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1020 | Uint32 | 1000 | 0 | 1000000 | Border value meters | Frame border |
1030 | Uint8 | - | 0 | 1 | 0 - Circle | Shape type |
1 - Rectangle | ||||||
1031 | Uint8 | - | 0 | 2 | 0 – Low | Priority |
1 – High | ||||||
2 – Panic | ||||||
1032 | Uint8 | - | 0 | 3 | 0 - No event | Generate event |
1 - On entering zone | ||||||
2 - On exiting zone | ||||||
3 - On both | ||||||
1033 | float | - | -180 | 180 | Rectangle left down corner X coordinate | Longitude X1 |
Or X1 Coordinate circle middle point | ||||||
1034 | float | - | -90 | 90 | Rectangle left down corner Y1 coordinate | latitude Y1 |
Or Y1 Coordinate circle middle point | ||||||
1035 | float | - | -180 | 180 | Rectangle right upper corner X2 coordinate | longitude X2 |
1035 | float | 1000 | 0 | 1000000 | X2 coordinate radius of circle | longitude X2 |
1036 | float | - | -90 | 90 | Rectangle right upper corner Y2 coordinate | latitude Y2 |
If circle ID 1036 is not used |
Similarly to a group defined in the upper table:
Zone number | Parameter | |||||||
---|---|---|---|---|---|---|---|---|
Shape | Priority | Generate event | X1 | Y1 | X2 | Radius | Y2 | |
1 | 1030 | 1031 | 1032 | 1033 | 1034 | 1035 | 1035 | 1036 |
2 | 1040 | 1041 | 1042 | 1043 | 1044 | 1045 | 1045 | 1046 |
3 | 1050 | 1051 | 1052 | 1053 | 1054 | 1055 | 1055 | 1056 |
4 | 1060 | 1061 | 1062 | 1063 | 1064 | 1065 | 1065 | 1066 |
5 | 1070 | 1071 | 1072 | 1073 | 1074 | 1075 | 1075 | 1076 |
Parameters
ID | Parameter name | Value type | Value description | Min Value | max Value |
---|---|---|---|---|---|
1300 | I/O#1 property parameter | S8 | 0 - disable | 0 | 1 |
1 - enable | |||||
1301 | I/O#1 priority parameter | S8 | 0 - Low | 0 | 2 |
1 - High | |||||
2 - Panic | |||||
1302 | I/O#1 High level | S32 | used to set thresholds for I/O properties to generate events. | -2147483647 | 2147483647 |
1303 | I/O#1 Low level | S32 | used to set thresholds for I/O properties to generate events. | -2147483647 | 2147483647 |
1304 | I/O#1 logic operand | S8 | 0 - on range exit | 0 | 5 |
1 - on range entrance | |||||
2 - both | |||||
3 - monitoring | |||||
4 - hysteresis | |||||
5 - on changes | |||||
1305 | I/O#1 averaging length | S32 | Parameter defines I/O property sample length to average | 0 | 2592000 |
Similarly to a group defined in the upper table
I/O parameters
I/O Element Number | I/O element parameters |
---|---|
Digital Input 1 | 1300-1305 |
Digital Input 2 | 1310-1315 |
Digital Input 3 | 1320-1325 |
Analog Input 1 | 1330-1335 |
Digital Output 1 | 1340-1345 |
Digital Output 2 | 1350-1355 |
GNSS PDOP | 1360-1365 |
GNSS HDOP | 1370-1375 |
External Voltage | 1380-1385 |
GNSS Power | 1390-1395 |
Movement Sensor | 1400-1405 |
Trip distance | 1410-1415 |
GSM Operator | 1420-1425 |
Speed (Km/h) | 1430-1435 |
iButton ID | 1440-1445 |
Mode | 1450-1455 |
GSM Signal | 1460-1465 |
Deep Sleep | 1470-1475 |
Cell ID | 1480-1485 |
Area Code | 1490-1495 |
Dallas Temperature 1 | 1500-1505 |
Reserved | 1510-1515 |
Reserved | 1520-1525 |
Reserved | 1530-1535 |
Reserved | 1110-1115 |
Ignition | 1120-1125 |
Total Distance | 1130-1135 |
Reserved IO1 | 1140-1145 |
Reserved IO2 | 1150-1155 |
RFID | 1160-1165 |
LLS Fuel1 | 1720- 1725 |
LLS Temp1 | 1730- 1735 |
LLS Fuel2 | 1740- 1745 |
LLS Temp2 | 1750- 1755 |
LLS Fuel3 | 1760- 1765 |
LLS Temp3 | 1770- 1775 |
LLS Fuel4 | 1780- 1785 |
LLS Temp4 | 1790- 1795 |
LLS Fuel5 | 1800- 1805 |
LLS Temp5 | 1810- 1815 |
Dallas Temperature 2 | 1820- 1825 |
Dallas Temperature 3 | 1830- 1835 |
Dallas Temperature 4 | 1840- 1845 |
Dallas Temperature ID 1 | 1850- 1855 |
Dallas Temperature ID 2 | 1860- 1865 |
Dallas Temperature ID 3 | 1870- 1875 |
Dallas Temperature ID 4 | 1880- 1885 |
LVCAN
Parameter ID | Parameter Type | Recommended value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
1600 | Uint8 | 0 | 0 | 2 | 0 – Auto detect | LVCAN Mode |
1 – LV-CAN200 | ||||||
2 – ALL-CAN300 | ||||||
1601 | Uint8 | 1 | 0 | 1 | 0 - Disable | Send data with 0, if ignition is off |
1 - Enable |
Configuration example
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
2000 | Uint8 | - | 0 | 3 | 0 – Disabled | Priority |
1 – Low | ||||||
2 – High | ||||||
3 – Panic | ||||||
2001 | Uint8 | 3 | 0 | 4 | 0 - On range exit | Generation type |
1 - On range entrance | ||||||
2 - On both | ||||||
3 - Monitoring | ||||||
4 - Hysteresis | ||||||
5 - On change | ||||||
2002 | Uint8 | - | 0 | 255 | High value | High level |
2003 | Uint8 | 0 | 0 | 255 | Low value | Low level |
2004 | Uint8 | - | 0 | 265535 | value | Average constant value |
Allowed values
CAN IO Element | Minimum value | Maximum value |
---|---|---|
Speed | 0 | 250 |
Accelerator pedal position | 0 | 100 |
Total fuel used | 0 | 99999999 |
Fuel level (liters) | 0 | 100 |
Engine RPM | 0 | 8200 |
Vehicle distance | 0 | 2145000000 |
Fuel level (proc.) | 0 | 100 |
Program number | 0 | 999 |
Other CAN settings
Similarly to a group defined in the upper table:
Name | Parameter | |||||||
---|---|---|---|---|---|---|---|---|
Priority | Generation type | Low level | High level | Avg const' | ||||
Vehicle speed | 2000 | 2001 | 2002 | 2003 | 2004 | |||
Acceleration Pedal Position | 2010 | 2011 | 2012 | 2013 | 2014 | |||
Total fuel used | 2020 | 2021 | 2022 | 2023 | - | |||
Fuel level (liters) | 2030 | 2031 | 2032 | 2033 | 2034 | |||
Engine RPM | 2040 | 2041 | 2042 | 2043 | 2044 | |||
Total Mileage | 2050 | 2051 | 2052 | 2053 | - | |||
Fuel Level (percent) | 2060 | 2061 | 2062 | 2063 | 2064 | |||
Program Number | 2070 | 2071 | 2072 | 2073 | - | |||
Module ID | 2080 | 2081 | 2082 | 2083 | - | |||
Engine Worktime | 2090 | 2091 | 2092 | 2093 | - | |||
Engine Worktime (counted) | 2100 | 2101 | 2102 | 2103 | - | |||
Total Mileage (counted) | 2110 | 2111 | 2112 | 2113 | - | |||
Fuel Consumed (counted) | 2120 | 2121 | 2122 | 2123 | - | |||
Fuel Rate | 2130 | 2131 | 2132 | 2133 | 2134 | |||
AdBlue Level (percent) | 2140 | 2141 | 2142 | 2143 | 2144 | |||
AdBlue Level (liters) | 2150 | 2151 | 2152 | 2153 | 2154 | |||
Engine Load | 2160 | 2161 | 2162 | 2163 | 2164 | |||
Engine Temperature | 2170 | 2171 | 2172 | 2173 | 2174 | |||
Axle 1 Load | 2180 | 2181 | 2182 | 2183 | 2184 | |||
Axle 2 Load | 2190 | 2191 | 2192 | 2193 | 2194 | |||
Axle 3 Load | 2200 | 2201 | 2202 | 2203 | 2204 | |||
Axle 4 Load | 2210 | 2211 | 2212 | 2213 | 2214 | |||
Axle 5 Load | 2220 | 2221 | 2222 | 2223 | 2224 | |||
Control State Flags | 2230 | 2231 | 2232 | 2233 | - | |||
Agricultural Machinery Flags | 2240 | 2241 | 2242 | 2243 | - | |||
Harvesting Time | 2250 | 2251 | 2252 | 2253 | - | |||
Area of Harvest | 2260 | 2261 | 2262 | 2263 | - | |||
Mowing Efficiency | 2270 | 2271 | 2272 | 2273 | 2274 | |||
Grain Mown Volume | 2280 | 2281 | 2282 | 2283 | - | |||
Grain Moisture | 2290 | 2291 | 2292 | 2293 | 2294 | |||
Harvesting Drum RPM | 2300 | 2301 | 2302 | 2303 | 2304 | |||
Gap Under Harvesting Drum | 2310 | 2311 | 2312 | 2313 | 2314 | |||
Security State Flags | 2320 | 2321 | 2322 | 2323 | - | |||
Tachograph Total Vehicle Distance | 2330 | 2331 | 2332 | 2333 | - | |||
Trip Distance | 2340 | 2341 | 2342 | 2343 | - | |||
Tachograph Vehicle Speed | 2350 | 2351 | 2352 | 2353 | 2354 | |||
Tachograph Driver Card Presence | 2360 | 2361 | 2362 | 2363 | - | |||
Driver 1 States | 2370 | 2371 | 2372 | 2373 | - | |||
Driver 2 States | 2380 | 2381 | 2382 | 2383 | - | |||
Driver 1 Continuous Driving Time | 2390 | 2391 | 2392 | 2393 | - | |||
Driver 2 Continuous Driving Time | 2400 | 2401 | 2402 | 2403 | - | |||
Driver 1 Cumulative Break Time | 2410 | 2411 | 2412 | 2413 | - | |||
Driver 2 Cumulative Break Time | 2420 | 2421 | 2422 | 2423 | - | |||
Driver 1 Selected Activity Duration | 2430 | 2431 | 2432 | 2433 | - | |||
Driver 2 Selected Activity Duration | 2440 | 2441 | 2442 | 2443 | - | |||
Driver 1 Cumulative Driving Time | 2450 | 2451 | 2452 | 2453 | - | |||
Driver 2 Cumulative Driving Time | 2460 | 2461 | 2462 | 2463 | - | |||
Driver 1 ID High | 2470 | 2471 | 2472 | 2473 | - | |||
Driver 1 ID Low | 2480 | 2481 | 2482 | 2483 | - | |||
Driver 2 ID High | 2490 | 2491 | 2492 | 2493 | - | |||
Driver 2 ID Low | 2500 | 2501 | 2502 | 2503 | - | |||
Battery temperature | 2510 | 2511 | 2512 | 2513 | 2514 | |||
Battery level | 2520 | 2521 | 2522 | 2523 | 2524 | |||
Door Status | 2530 | 2531 | 2532 | 2533 | - | |||
DTC Faults | 2540 | 2541 | 2542 | 2543 | - | |||
Slope Of Arm | 2550 | 2551 | 2552 | 2553 | - | |||
Rotation of Arm | 2560 | 2561 | 2562 | 2563 | - | |||
Eject of Arm | 2570 | 2571 | 2572 | 2573 | - | |||
Horizontal Distance Arm Vehicle | 2580 | 2581 | 2582 | 2583 | - | |||
Height Arm Above Ground | 2590 | 2591 | 2592 | 2593 | - | |||
Drill RPM | 2600 | 2601 | 2602 | 2603 | - | |||
Amount of Spread Salt Square Meter | 2610 | 2611 | 2612 | 2613 | - | |||
Battery Voltage | 2620 | 2621 | 2622 | 2623 | - | |||
Amount of Spread Fine Grained Salt | 2630 | 2631 | 2632 | 2633 | - | |||
Amount of Spread Coarse Grained Salt | 2640 | 2641 | 2642 | 2643 | - | |||
Amount of Spread DiMix | 2650 | 2651 | 2652 | 2653 | - | |||
Amount of Spread Coarse Grained Calcium | 2660 | 2661 | 2662 | 2663 | - | |||
Amount of Spread Calcium Chloride | 2670 | 2671 | 2672 | 2673 | - | |||
Amount of Spread Sodium Chloride | 2680 | 2681 | 2682 | 2683 | - | |||
Amount of Spread Magnesium Chloride | 2690 | 2691 | 2692 | 2693 | - | |||
Amount of Spread Gravel | 2700 | 2701 | 2702 | 2703 | - | |||
Amount of Spread Sand | 2710 | 2711 | 2712 | 2713 | - | |||
Width Pouring Left | 2720 | 2721 | 2722 | 2723 | - | |||
Width Pouring Right | 2730 | 2731 | 2732 | 2733 | - | |||
Salt Spreader Working Hours | 2740 | 2741 | 2742 | 2743 | - | |||
Distance During Salting | 2750 | 2751 | 2752 | 2753 | - | |||
Load Weight | 2760 | 2761 | 2762 | 2763 | - | |||
Retarder Load | 2770 | 2771 | 2772 | 2773 | - | |||
Cruise Time | 2780 | 2781 | 2782 | 2783 | - | |||
CNG Status | 2790 | 2791 | 2792 | 2793 | - | |||
CNG Used | 2800 | 2801 | 2802 | 2803 | - | |||
CNG Level | 2810 | 2811 | 2812 | 2813 | - | |||
Oil Level | 2820 | 2821 | 2822 | 2823 | - |