Changes

299 bytes added ,  09:24, 30 May 2018
m
no edit summary
Line 1: Line 1:  
{{Template:FMB FW development notice}}
 
{{Template:FMB FW development notice}}
   −
Sets digital outputs to ON or OFF state (timeout is valid only when DOUT state is changing from OFF to ON).<br/>Example:<br/>"setdigout 01 30 60" will set DOUT1 to low level (for infinite time) and DOUT2 to high level for 60 seconds.<br/><br/>Example:<br/>"setdigout 11" will set DOUT1 and DOUT2 to high level for infinite time.
+
Sets digital outputs to ON or OFF state (timeout is valid only when DOUT state is changing from OFF to ON).
 +
<br/><br/>
 +
For devices with 2 digital outputs:<br>
 +
Example:<br/>"setdigout 01 30 60" will set DOUT1 to low level for 30 seconds and DOUT2 to high level for 60 seconds.
 +
<br/><br/>
 +
Example:<br/>"setdigout 11" will set DOUT1 and DOUT2 to high level for infinite time.
 +
<br/><br/>
 +
Example:<br/>"setdigout 11  30" will set DOUT1 to high level for infinite time and DOUT2 to high level for 30 seconds.
 +
<br/><br/>
 +
For devices with 1 digital output:<br>
 +
Example:<br/>"setdigout 1 45" will set DOUT1 to high level for 45 seconds.