Sets digital outputs to ON or OFF state (timeout is valid only when DOUT state is changing from OFF to ON).<br/>Example:<br/>"setdigout 01 30 60" will set DOUT1 to low level (for infinite time) and DOUT2 to high level for 60 seconds.<br/><br/>Example:<br/>"setdigout 11" will set DOUT1 and DOUT2 to high level for infinite time.
+
Sets digital outputs to ON or OFF state (timeout is valid only when DOUT state is changing from OFF to ON).
+
<br/><br/>
+
For devices with 2 digital outputs:<br>
+
Example:<br/>"setdigout 01 30 60" will set DOUT1 to low level for 30 seconds and DOUT2 to high level for 60 seconds.
+
<br/><br/>
+
Example:<br/>"setdigout 11" will set DOUT1 and DOUT2 to high level for infinite time.
+
<br/><br/>
+
Example:<br/>"setdigout 11 30" will set DOUT1 to high level for infinite time and DOUT2 to high level for 30 seconds.
+
<br/><br/>
+
For devices with 1 digital output:<br>
+
Example:<br/>"setdigout 1 45" will set DOUT1 to high level for 45 seconds.