Changes

2,517 bytes added ,  13:20, 26 April 2018
m
Line 7: Line 7:  
* <span style=color:#F6A83E>RS485</span> - Select RS-485 functionality.
 
* <span style=color:#F6A83E>RS485</span> - Select RS-485 functionality.
   −
===RS-232 mode===
+
===RS-232 modes===
   −
RS-232 supports several modes:
+
RS-232 supports following modes:
* Log Mode – suitable for debugging/logging;
+
* <span style=color:#F6A83E>Log Mode</span> – suitable for debugging/logging;
* NMEA – NMEA logs are sent via RS232 or RS485;
+
* <span style=color:#F6A83E>NMEA</span> – NMEA logs are transferred;
* LLS – LLS sensors support;
+
* <span style=color:#F6A83E>LLS</span> – LLS sensor support;
* LCD – external LCD support;
+
* <span style=color:#F6A83E>LCD</span> – external LCD support;
* RFID HID – RFID card reader support;
+
* <span style=color:#F6A83E>RFID HID</span> – RFID HID reader support;
* RFID MF7 - RFID card reader support;
+
* <span style=color:#F6A83E>RFID MF7</span> - RFID MF7 reader support;
* Garmin FMI – Garmin support;
+
* <span style=color:#F6A83E>Garmin FMI</span> – Garmin support;
* TCP ASCII – for routing any input string from external device to server;
+
* <span style=color:#F6A83E>TCP ASCII</span> – for routing any input string from external device to the server;
* TCP Binary – for routing any binary input data from external device to server.
+
* <span style=color:#F6A83E>TCP Binary</span> – for routing any binary input data from external device to the server.
    
===RS-232 Baudrate and parity===
 
===RS-232 Baudrate and parity===
   −
Every RS232 mode support different baudrates, but each mode has its own default baudrate value. Default baudrate values for each RS232 working mode are provided in table 14. Also, default parity options are provided in table 14.
+
Every RS-232 mode supports different baudrates, but each mode has its own default baudrate value. Default baudrate and parity values for each RS-232 mode are provided in the table below.
 +
 
 +
{| class="wikitable"
 +
|+
 +
! style="width: 100px; background: black; color: white;" rowspan=3 | Mode
 +
! style="width: 300px; background: black; color: white;" colspan=3 | Default settings
 +
|-
 +
| style="width: 75px;text-align: left; vertical-align: top;" colspan=2 | RS-232
 +
| style="width: 75px;text-align: left; vertical-align: top;" | RS-485
 +
|-
 +
| style="width: 75px;text-align: left; vertical-align: top;" | Baudrate
 +
| style="width: 75px;text-align: left; vertical-align: top;" | Parity
 +
| style="width: 75px;text-align: left; vertical-align: top;" | Baudrate
 +
|-
 +
! style="text-align: left; vertical-align: top;" | Log Mode
 +
| style="text-align: left; vertical-align: top;" | 115200
 +
| style="text-align: left; vertical-align: top;" rowspan=9 | None
 +
| style="text-align: left; vertical-align: top;" | 115200
 +
|-
 +
! style="text-align: left; vertical-align: top;" | NMEA
 +
| style="text-align: left; vertical-align: top;" | 115200
 +
| style="text-align: left; vertical-align: top;" | 115200
 +
|-
 +
! style="text-align: left; vertical-align: top;" | LLS
 +
| style="text-align: left; vertical-align: top;" | 19200
 +
| style="text-align: left; vertical-align: top;" | 19200
 +
|-
 +
! style="text-align: left; vertical-align: top;" | LCD
 +
| style="text-align: left; vertical-align: top;" | 57600
 +
| style="text-align: left; vertical-align: top;" | -
 +
|-
 +
! style="text-align: left; vertical-align: top;" | RFID HID
 +
| style="text-align: left; vertical-align: top;" | 57600
 +
| style="text-align: left; vertical-align: top;" | -
 +
|-
 +
! style="text-align: left; vertical-align: top;" | RFID MF7
 +
| style="text-align: left; vertical-align: top;" | 9600
 +
| style="text-align: left; vertical-align: top;" | -
 +
|-
 +
! style="text-align: left; vertical-align: top;" | Garmin FMI
 +
| style="text-align: left; vertical-align: top;" | 9600
 +
| style="text-align: left; vertical-align: top;" | -
 +
|-
 +
! style="text-align: left; vertical-align: top;" | TCP ASCII
 +
| style="text-align: left; vertical-align: top;" | 115200
 +
| style="text-align: left; vertical-align: top;" | 57600
 +
|-
 +
! style="text-align: left; vertical-align: top;" | TCP Binary
 +
| style="text-align: left; vertical-align: top;" | 115200
 +
| style="text-align: left; vertical-align: top;" | 57600
 +
|-
 +
|}
    
===RS-232 TCP Binary mode settings===
 
===RS-232 TCP Binary mode settings===
   −
RS232 TCP Binary Mode has additional configurable parameters for advanced data filtering.
+
RS-232 TCP Binary Mode has additional configurable parameters for advanced data filtering.
    
===RS232 Garmin Mode settings===
 
===RS232 Garmin Mode settings===
   −
Garmin FMI mode has addditional filtering capabilities. It is possible to filter Ping and Unicode packets. If Ping filter will be enabled, then Ping packets will be blocked. If Unicode filter will be enabled, then Unicode packets will not be sent to server. Both filters may be enabled for simulatneous work.
+
Garmin FMI mode has addditional filtering capabilities. It is possible to filter Ping and Unicode packets. If <span style=color:#F6A83E>Ping</span> filter will be enabled, then Ping packets will be blocked. If <span style=color:#F6A83E>Unicode</span> filter will be enabled, then Unicode packets will not be sent to server. Both filters may be enabled for simulatneous work.
    
===RS485 working mode===
 
===RS485 working mode===

Navigation menu