Difference between revisions of "TAT100 Stable firmware"

From Wiki Knowledge Base | Teltonika GPS
 
(No difference)

Latest revision as of 10:13, 5 September 2024

Main Page > Autonomous Trackers > TAT100 > TAT100 Firmware and configurator > TAT100 Stable firmware


Warning.png CAUTION!
Both firmwares (Modem and BlueNRG) must be flashed into device. Failing so can lead to unexpected device behavior and rapid battery discharge.
TAT140 BlueNRG & Modem FIRMWARE UPDATE GUIDE

TATXYZ FIRMWARE UPDATE GUIDE

Download Firmware and Configurator from STABLE FIRMWARE or SHORT-TERM FIRMWARE pages.

After device connection to Configurator:
1) Select Update firmware;
2) Select to flash Firmware(*.e.XIM) file;
3) Click on file;
4) And select Open.

Wait until the device will upload the firmware.

TAT100Firmware.png

When parameters successfully loaded:
1) Select Update firmware;
2) Select to flash BlueNRG firmware(*.bin);
3) Click on file;
4) And select Open.

TAT100NRG.png

TAT100 Stable Firmware and Software

STABLE FIRMWARE
FIRMWARE VERSION: 55.00.16.Rev.569
CONFIGURATOR VERSION: 1.7.74_E.TAT1_R.7
BlueNRG VERSION: 1.0.3.Rev.00
For TAT100 HW version 31 please contact us via Help Desk.
RELEASE DATE:
2024.08.19


DOWNLOAD
Firmware & BlueNRG for [TAT100]
Firmware & BlueNRG for [TAT100 HW31]
Firmware & BlueNRG for [TAT100 HW62]
Configurator
DOWNLOAD ALL
DOWNLOAD ALL FOR [TAT100]
DOWNLOAD ALL FOR [TAT100 HW31]
DOWNLOAD ALL FOR [TAT100 HW62]
Backup FMB Firmware
On request via Teltonika HelpDesk

TAT100 Hardware version identification

  • If Serial Number [S/N] is greater than 1122473261, then device version: TAT100 HW: 62.
  • If Serial Number [S/N] is less than 1122473261, then device version: TAT100 HW: 31.

ORDERS AFTER 2022-03-17 WILL BE WITH TAT100 HARDWARE: 62

Warning.pngCAUTION!

When updating firmware via FOTA WEB, pay attention to notice above.


CHANGELOG

VERSION RELEASE DATE CONFIGURATOR CHANGES FIRMWARE CHANGES
Firmware version: 55.00.16.Rev.569

BlueNRG version: 10.0.3.Rev.00 for TAT100 HW ver.: 31
1.0.3.Rev.00 for TAT100 HW ver.: 62
Configurator version: 1.7.74_E.TAT1_R.7

2024.08.19
  • Added an option to configure TLS functionality.
  • Added an option to configure SMS record sending.
  • Added an option to configure MQTT Azure and AWS support.
  • Added an option to configure I am alive feature.
  • Added TLS functionality feature.
  • Added SMS record sending feature.
  • Added MQTT Azure and AWS support.
  • Added I am alive feature.
  • Fixed X, Y and Z IO elements not being included with First Power On record.
  • Extended On Stop and On Move periodic timers to maximum value of 7 days.
  • Improvements to Static Navigation logic in no GPS situation.
  • New AVL ID 69 value added (4 - no GPS in Static Navigation).
  • Improved Recovery mode trigger logic in Lost Sensor scenario.
  • Added error code when BLE sensor is lost.
VERSION RELEASE DATE CONFIGURATOR CHANGES FIRMWARE CHANGES
Firmware version: 55.00.16.Rev.564

BlueNRG version: 10.4.12 for TAT100 HW ver.: 31
0.4.12 for TAT100 HW ver.: 62
Configurator version: 1.7.74_B.TAT1_R.6

2024.03.12
  • Fixed configurator crash after firmware update.
  • Added cell ID I/O elements
  • Fixed error when disabling BLE features in configuration.
  • Added GSM area code I/O element
  • Simplified EYE sensor configuration.
  • Added Autonomous Alarm System feature.
  • Fixed periodic timer starting in Recovery mode.
  • Improved backup tracker scan procedure.
  • Fixed issue with GPS fix with First Power On record.
  • Improved energy management in sleep mode when device is in motion.
  • Fixed crash on BLE sensor alarm.
  • Bluetooth scanning and data parsing optimization.
  • DNS resolve improvements.
  • Fixed periodic timer starting when tracking scenario selected as None.
  • Changed default movement sensitivity to 150 mG
  • Changed default GNSS mode to GLONASS, GPS and GALILEO
  • Fixed EYE sensor data multiplier for correct data displaying.
  • Fixed issue if GPRS is lost during record sending.
  • Fixed GPRS command processing in UDP mode.
  • Improved received SMS reading process.
  • Improved connection to Fota process.
  • Fixed BLE sensor data not being included in periodic records.
  • Improved static navigation logic.
  • Improved Bluetooth scan stability.
  • Added BLE beacons for Recovery mode trigger.
  • Movement logic rework.
  • Added condition to stop GNSS search if less than 3 satellites found in the first 60 seconds.
Firmware version: 55.00.16.Rev.545

BlueNRG version: 10.3.12 for TAT100 HW ver.: 31
0.3.12 for TAT100 HW ver.: 62
Configurator version: 1.7.16_E.TAT100.R23 RELEASE

2022.08.23
  • No changes
  • Fixed issue with incorrectly detected SIM slot for eSIM devices.
Firmware version: 55.00.16.Rev.543
BlueNRG version: 10.3.12 for TAT100 HW ver.: 31
0.3.12 for TAT100 HW ver.: 62
Configurator version: 1.7.16_E.TAT100.R23 RELEASE
2022.08.08
  • Updated Teltonika Configurator version to set Central device default IMEI to 300000000000000
  • Added Recovery mode option
  • Added I/O element of Recovery Mode
  • Added more options of movement sensitivity threshold [50-1000mG]
  • Configurator for BLE FW and Backup FW was merged into one.
  • SMS command created for getting device statistics
  • Protection from writing other devices FW
  • Added condition to prevent modem waking up at midnight if scheduler is configured
  • Added reconfiguration mechanism that lets FW work with / without SMPS filterMissing
  • Fixed issue of missing 4th sensor's data with Monitoring operand
  • Fixed too frequent / unnecessary scans with all sensors configured as monitoring
  • Fixed sensors scan starting with monitoring operand when Backup tracker is configured
  • Backup tracker scan not starting right after
  • Time synchronization every 24 hours
  • Fixed LBS data sending issue
  • New AVL ID 20015 for Modem UpTime (in seconds)
  • Added response sending if recovery command is sent through GPRS
  • The next periodic record after Recovery mode deactivation being sent with AVL ID 20012 - fixed
  • Reduced EQ Core update frequency
  • Fixed battery consumption issue when GSM is jammed.
  • LED status changed from constant on to blinking mode to save the battery
  • Added Recovery mode feature
  • Implemented Recovery mode activation from the Backup tracking alarm
  • Added EYE sensors support
  • Fixed Minor bugs regarding the sensors
  • Fixed Short period Recovery Mode records
  • Extended Backup Tracker: Central device IMEI range
  • Backup tracker: Scanning logic has been changed, scan duration is not configurable anymore, it is up to 60 seconds by default now.
  • Implemented Record timestamp shift feature
  • Fixed BLE sensor records with wrong event ID being sent
  • Fixed BLE sensor record duplicates with On change operand
  • Fixed BLE sensor On Exit record not generating when switching to sleep mode
  • Fixed Custom1 sensor data in SMS being sent as NaN (empty)
  • Fixed duplicate BLE sensor data after waking up
  • Changed required packets amount in backup tracker scenario and minimal scan duration
  • Fixed backup tracker alarm not triggering just before wakeup
  • Fixed backup tracker not detecting enough packets during BLE scan
  • Periodic records do not affect backup tracker alarm record generation
Firmware version: 55.00.16.Rev.522
BlueNRG version: 10.2.21.Rev.01
Configurator version: 1.7.16_R.TAT100.R2
2021.12.21
  • Improved battery safety features
  • Fixed stuck download during FOTA update
  • Fixed device not restarting to update FW after FOTA download
  • Improved main device packet filtering
  • Improved battery voltage measurement
  • Fixed the device not restarting after FOTA WEB update when it happens at the same time as periodic record
  • Fixed random statistic losses
  • Fixed GNSS module status not being accurate in Teltonika Configurator
  • Improved static navigation mode
  • Fixed scheduler time resync timer not working properly
  • Fixed statistic not being deleted from RAM
Firmware version: 55.00.15.Rev.519
BlueNRG version: 10.2.14
Configurator version: 1.7.16_R.TAT100.R2
2021.10.19
  • Fixed fake movement detection on startup
  • Fixed problem when the device is stuck in On Stop tracking mode after reconfiguration
  • Added Power-On reason data and fixed version changes to device statistics
  • Fixed Backup tracker issue where the alarm mode is not immediately activated when the central device disappears
  • Fixed empty GSM I/O elements
  • Fixed an issue where UTC is added after each reconfiguration
  • Added record printing to Dump log
  • LBS data is not included in records if GNSS fix was caught
  • Fixed NTP timesync failure if offset is zero
  • Improved record creation (wake up from sleep) during Backup tracker alarms





  • Improved GNSS module control with Static Navigation and LBS
  • Added prevention from inappropriate record generation if the battery is low (HW watchdog)
  • Added statistic element for USB connected uptime
  • Added timestamp to BlueNRG serial prints
  • Minor improvement for BlueNRG firmware update via configurator
  • Added filter for LBS cell_id duplicates
  • Improved Bluetooth sensor record creation with 'On Change' operand
  • Added Bluetooth sensor support
  • Added condition to skip LBS data update if location source is only GNSS
  • Increased retries of AT+# command in order to avoid empty LBS data from modem
  • Changed Open link timeout to 15s
  • Fixed an issue where the tracking mode would change from the scheduler to periodic
  • Improved logic for multiple FOTA Web tasks update in the same connection
  • Implemented rule for additional connection to FOTA Web after baseband firmware update
  • Added accelerometer version information inside '.info' serial command
  • Fixed an issue with battery voltage I/O element when record saving is overlapping with a firmware update
  • Fixed Scheduler record sending at midnight
  • Fixed missed LBS values inside I/O elements
  • Fixed an issue when GNSS speed is not zero while the device is in a stationary position
  • General minor improvements
55.00.10.Rev.509
BlueNRG: 10.2.3_Rev.00
1.7.16_E.TAT100_04
2021.05.10
  • Added Test Connection button
  • Temporarily removed Secondary Server Settings
  • Tracking Period default value changed to 28800 (s)
  • Implemented Test Connection feature.
  • Added BlueNRG logging to DUMP files
  • Added LBS data logging to DUMP files
  • Added protection that blocks FMB firmware flash to AT devices
  • Added time-sync update with asset purpose command
  • Improved periodic record timer logic
  • Improved battery voltage measurement
  • Improved periodic GPRS data sending while USB is connected to the device
  • Disabled SMPS filter
  • Fixed record sending when movement is triggered at all times
  • Improved NTP time-sync
55.00.05.Rev.510
BlueNRG: 0.1.7
2020.12.03
  • Removed tracking scenarios
  • Removed speed source parameter
  • Removed record saving/sending without TS parameter
  • Removed LED Indication parameter
  • Removed NTP resync parameter
  • Implemented FOTA support.
  • Improved GNSS position capturing.
  • Reworked Periodic and Scheduler tracking counters.
  • Implemented device logging via USB.
  • Implemented statistics acquisition to flash memory.
55.00.05.Rev.507
BlueNRG: 0.1.5
2020.09.29
  • Implemented GNSS Source configuration. Available options: BeiDou, GLONASS, Galileo and GPS.
  • Added I/O elements: Data Mode, GSM Signal, GNSS Status, GNSS PDOP, GNSS HDOP, Speed, GSM Cell ID, GSM Area Code, Battery Voltage, Active GSM Operator, ICCID, Coordinates ISO6709.
  • Added SMS command autorization via Login and Password logic.
  • Implemented 'Codec 8', 'Codec 8 Extended' and 'Codec 12' protocols.
  • Implemented NTP, NITZ and GNSS time synchronization sources.
  • Implemented ability to send GPRS data from device via TCP or UDP channels.
  • Implemented connection to server timeouts.
  • Ported TLS encryption functionality from other Teltonika devices.
  • Implemented Periodic and Scheduler tracking.
  • Implemented BlueNRG firmware update via GPRS. This function will be used to reflash BlueNRG firmware via FOTA WEB.
  • Added GSM number authorization logic.