Jump to content

Test-AC: Difference between revisions

From Teltonika Telematics Wiki
No edit summary
No edit summary
(60 intermediate revisions by the same user not shown)
Line 1: Line 1:
=SECO Scenario=
==Authorized Read Notification==
==Description==
'''Important: ''iButton Read Notification'' feature has been replaced with ''Authorized Read Notification'' starting from Firmware Ver.03.30.00''' <br>
The SECO scenario (Secure Engine Cut Off) is a static scenario module responsible for controlling a digital output (DOUT) to cut off the engine based on configurable speed and movement conditions. It is typically triggered by remote commands (SMS or GPRS) and is used for security or immobilization purposes.


=== <u> Parameters list </u>===
[[Image:Authorized_Read_Notification.gif|{{{general|size}}}||right]]
<table class="nd-othertables_2" style="width:100%; border-collapse: collapse;">
Authorized read notification feature allows the control of selected DOUT for a configured period, when '''Authorized ID''' is read using '''1-Wire''', '''RFID Reader''' or when '''Authorized Beacon''' is detected. If Authorized ID List is empty or Beacon detection is set to '''All''', then any detected ID or Beacon can control selected DOUT. Parameter '''Depend on Ignition''' allows to disable DOUT control, while Ignition is being detected. It is necessary to select at least one source for this functionality to work.
<tr>
<th style="width:1%; vertical-align: middle; text-align: center;">PARAMETER NAME</th>
<th style="width:1%; vertical-align: middle; text-align: center;">PARAMETER ID (RELATED AVL ID)</th>
<th style="width:5%; vertical-align: middle; text-align: center;">DESCRIPTION</th>
<th style="width:6%; vertical-align: middle; text-align: center;">VALUES</th>
</tr>
<tr>


<td style="vertical-align: middle; text-align: center;"> SECO DOUT status </td>
Authorized Read Notification parameters:
<td style="vertical-align: middle; text-align: center;"> 396</td>
<td style="vertical-align: middle; text-align: center;"> SECO DOUT status. </td>
<td style="vertical-align: middle; text-align: left;">'''0''' = SECO DOUT is '''OFF''' <br> '''1''' = SECO DOUT is '''pulsing''' <br> '''2''' = SECO DOUT is '''ON''' </td>


</tr>
*'''Output Control''' – available scenario settings for module Digital output activation/deactivation
<tr>
*'''DOUT ON Duration''' – a value in seconds, for how long {{{text_dout|DOUT1/DOUT2}}} should be active or inactive.
*'''Authorization ID List Checking''' - Provides Authorized ID information from a designated source.
**FMB devices that do not have RS232 will have support for 1-Wire and Beacon only.
**FMB devices that do not have RS232 and 1-Wire will have support for Beacon only.
*'''Depend on Ignition''' - Output will be triggered only if ignition is off.


<td style="vertical-align: middle; text-align: center;"> Priority </td>
'''Note:''' Authorized read notification is disabled in '''deep sleep''', '''online deep sleep''' and '''ultra deep sleep''' modes.
<td style="vertical-align: middle; text-align: center;"> 1039600 </td>
<td style="vertical-align: middle; text-align: center;"> SECO scenario priority. </td>
<td style="vertical-align: middle; text-align: left;"> '''0''' = SECO  scenario is '''disabled''' <br> '''1''' = SECO scenario is '''low''' <br> '''2''' = SECO scenario is '''high''' <br>
</td>
 
</tr>
<tr>
 
<td style="vertical-align: middle; text-align: center;"> Speed </td>
<td style="vertical-align: middle; text-align: center;"> 12254 </td>
<td style="vertical-align: middle; text-align: center;"> Speed threshold at which the configured digital output (DOUT) will be activated. </td>
<td style="vertical-align: middle; text-align: left;"> Minimum value = '''0'''<br> Maximum value = '''255''' <br> Default value = '''10''' </td>
 
</tr>
<tr>
 
<td style="vertical-align: middle; text-align: center;"> Speed pulse scenario </td>
<td style="vertical-align: middle; text-align: center;"> 12259 </td>
<td style="vertical-align: middle; text-align: center;">
Speed threshold at which the configured digital output (DOUT) will be toggled. </td>
<td style="vertical-align: middle; text-align: left;"> Minimum value = '''0'''<br> Maximum value = '''255''' <br>Default value = '''10''' </td>
 
</tr>
<tr>
 
<td style="vertical-align: middle; text-align: center;">
Speed check period </td>
<td style="vertical-align: middle; text-align: center;"> 12255 </td>
<td style="vertical-align: middle; text-align: center;"> Time span during which speed must be lower than configured for output to activate (GNSS on). </td>
<td style="vertical-align: middle; text-align: left;">  Minimum value = '''0'''<br> Maximum value = '''65535''' <br>Default value = '''10''' </td>
 
</tr>
<tr>
 
<td style="vertical-align: middle; text-align: center;">
Movement timeout</td>
<td style="vertical-align: middle; text-align: center;"> 12256 </td>
<td style="vertical-align: middle; text-align: center;"> Duration after which the DOUT will be activated if no movement is detected and GNSS is off. </td>
<td style="vertical-align: middle; text-align: left;">  Minimum value = '''0'''<br> Maximum value = '''65535''' <br>Default value = '''30''' </td>
 
</tr>
<tr>
 
<td style="vertical-align: middle; text-align: center;">Eventual records</td>
<td style="vertical-align: middle; text-align: center;"> 1039604</td>
<td style="vertical-align: middle; text-align: center;">Eventual records.</td>
<td style="vertical-align: middle; text-align: left;"> '''0''' = SECO status will be sent with both eventual and periodical records. <br> '''1''' = SECO status will be sent only when the event happens (an eventual record).</td>
 
</tr>
<tr>
 
<td style="vertical-align: middle; text-align: center;">Output control</td>
<td style="vertical-align: middle; text-align: center;">12252</td>
<td style="vertical-align: middle; text-align: center;">
SECO output control. </td>
<td style="vertical-align: middle; text-align: left;"> '''0''' = DOUT control is disabled <br> '''1''' = DOUT1 is controlled <br> '''2''' = DOUT2 is controlled <br> '''3''' = DOUT3 is controlled <br> '''4''' = DOUT4 is controlled</td>
 
</tr>
<tr>
 
<td style="vertical-align: middle; text-align: center;">Output pulse</td>
<td style="vertical-align: middle; text-align: center;">12253</td>
<td style="vertical-align: middle; text-align: center;">Pulse functionality adds additional output control which helps to slow down vehicle before fully disabling fuel pump.</td>
<td style="vertical-align: middle; text-align: left;"> '''0''' = Disabled <br> '''1''' = Enabled </td>
 
</tr>
<tr>
 
<td style="vertical-align: middle; text-align: center;">
DOUT on duration</td>
<td style="vertical-align: middle; text-align: center;">12257</td>
<td style="vertical-align: middle; text-align: center;"> Duration for how long DOUT should be active.</td>
<td style="vertical-align: middle; text-align: left;"> Minimum value = '''10'''<br> Maximum value = '''5000''' <br>Default value = '''1000''' </td>
 
</tr>
<tr>
 
<td style="vertical-align: middle; text-align: center;">DOUT off duration</td>
<td style="vertical-align: middle; text-align: center;">12258</td>
<td style="vertical-align: middle; text-align: center;"> A value in milliseconds, for how long DOUT should be inactive. </td>
<td style="vertical-align: middle; text-align: left;"> Minimum value = '''10'''<br> Maximum value = '''5000''' <br>Default value = '''1000''' </td>
 
</tr>
</table>

Revision as of 12:44, 3 April 2026

Authorized Read Notification

Important: iButton Read Notification feature has been replaced with Authorized Read Notification starting from Firmware Ver.03.30.00

Authorized read notification feature allows the control of selected DOUT for a configured period, when Authorized ID is read using 1-Wire, RFID Reader or when Authorized Beacon is detected. If Authorized ID List is empty or Beacon detection is set to All, then any detected ID or Beacon can control selected DOUT. Parameter Depend on Ignition allows to disable DOUT control, while Ignition is being detected. It is necessary to select at least one source for this functionality to work.

Authorized Read Notification parameters:

  • Output Control – available scenario settings for module Digital output activation/deactivation
  • DOUT ON Duration – a value in seconds, for how long DOUT1/DOUT2 should be active or inactive.
  • Authorization ID List Checking - Provides Authorized ID information from a designated source.
    • FMB devices that do not have RS232 will have support for 1-Wire and Beacon only.
    • FMB devices that do not have RS232 and 1-Wire will have support for Beacon only.
  • Depend on Ignition - Output will be triggered only if ignition is off.

Note: Authorized read notification is disabled in deep sleep, online deep sleep and ultra deep sleep modes.