Difference between revisions of "Template:FMA1 Electrical characteristics"

From Wiki Knowledge Base | Teltonika GPS
(One intermediate revision by one other user not shown)
Line 153: Line 153:
 
|-
 
|-
 
| style="text-align: left; background: #F6F6FB;"        | [[Image:Bw_nb.png|50px]]
 
| style="text-align: left; background: #F6F6FB;"        | [[Image:Bw_nb.png|50px]]
| style="text-align: left; background: #F6F6FB;"        | Analog Input error margin can increase if temperature varies. If Analog input is not connected {{{model|FMA1YX}}} will still measure certain numbers and it cannot be 0. This measurement is influenced by hardware components.
+
| style="text-align: left; background: #F6F6FB;"        | Analog Input error margin can increase if temperature varies.
 
|}
 
|}

Revision as of 13:02, 21 August 2018

Electrical characteristics

Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage:
Supply Voltage (Recommended Operating Conditions) 5 30 V
Digital Input:
Input resistance (DIN1) 120 kOhm
Input resistance (DIN2, DIN3) 15 kOhm
Input Voltage (Recommended Operating Conditions) 0 Supply voltage V
Input Voltage threshold (DIN1) 7.5 V
Input Voltage threshold (DIN2, DIN3) 2.6 V
Digital Output (Open Drain grade):
Drain Current (Digital Output OFF) 120 uA
Drain Current (Digital Output ON, Recommended Operating Conditions) 300 mA
Static Drain-Source Resistance (Digital Output ON) 300 mOhm
Analog Input:
Input voltage (Recommended Operating Conditions), Range 1 0 10 V
Input resistance, Range 1 120 kOhm
Measurement error 4.4 %
Additional error ±26 mV
Input Voltage (Recommended Operating Conditions) Range2 0 30 V
Input resistance, Range2 146.7 kOhm
Measurement error 4 %
Additional error ±40 mV
Output Supply Voltage 1-Wire:³
Supply voltage 3.3 3.6 V
Output inner resistance 10 Ohm
Output current (Uout > 3.0 V) 30 mA
Short circuit current (Uout = 0) 130 mA
Bw nb.png Analog Input error margin can increase if temperature varies.