Difference between revisions of "FMP100 First Start"

From Wiki Knowledge Base | Teltonika GPS
m (Text replacement - "Bluetooth(?!®)" to "Bluetooth®")
m (Protected "FMP100 First Start" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{Template:FMP1 First start card|model=FMP100|description=An easy Plug and Track real-time tracking terminal with GNSS, GSM and Bluetooth® connectivity|antenna=internal GNSS/GSM antennas|pic=[[Image:FMP100_demo.png|330px|right]]|sim_pin=[[FMP100 Security info|'''Security info''']]}}
+
{{Template:FMP1 First start card|model=FMP100|description=An easy Plug and Track real-time tracking terminal with GNSS, GSM and Bluetooth connectivity|antenna=internal GNSS/GSM antennas|pic=[[Image:FMP100_demo.png|330px|right]]|sim_pin=[[FMP100 Security info|'''Security info''']]}}
  
{{Template:2021_FMB First start config|model=FMP100|SIMtray=1|config_link=[[FMP100 Configuration|here]]|cfg_connect=FMP100-connected.png|dc_voltage=10-30 V|led_status_link=[[FMP100 LED status]]|first_time=FMB status screen-FMP100.jpg}}
+
{{Template:FMB First start config|model=FMP100|config_link=[[FMP100 Configuration|here]]|cfg_connect=FMP100-connected.png|dc_voltage=10-30 V|led_status_link=[[FMP100 LED status]]|first_time=FMB status screen-FMP100.jpg}}
 
{{Template:Mounting_recommendations
 
{{Template:Mounting_recommendations
 
|mounting_recommendations=
 
|mounting_recommendations=
Line 20: Line 20:
  
 
https://teltonika.lt/product/FMP100/
 
https://teltonika.lt/product/FMP100/
 
[[Category:FMP100]]
 

Revision as of 09:10, 20 April 2020

Main Page > Fast & Easy Trackers > FMP100 > FMP100 First Start
Qsg rut950 teltonika.PNG


An easy Plug and Track real-time tracking terminal with GNSS, GSM and Bluetooth connectivity

FMP100 demo.png




Know your device

FMP100-withoutcover.png


Set up your device

How to insert Micro-SIM card and connect the battery

  1. Insert the SIM tray removal tool into the hole on the SIM card tray and then push until the tray pops out.
  2. Split device cover to access battery connector inside.
  3. Connect the battery as shown to device.
  4. Gently close device cover back.
  5. Insert Nano-SIM card as shown with PIN request disabled or read our Wiki how to enter it later in Teltonika Configurator. Make sure that Nano-SIM card is fitted properly into the tray.
  6. Insert the SIM card tray back.
  7. After configuration, see see PC Connection (Windows).

Device is ready to be mounted.
FMP100 1.png      FMP100 2.png      FMP100 3.png      FMP100 4.png      FMP100 5.png      FMP1000 6.png

Alert.png
Nano-SIM card insertion/removal must be performed when device is powered off – external voltage and battery are disconnected. Otherwise Nano-SIM card might be damaged or device will not detect it.


PC Connection (Windows)

  1. Power-up FMP100 with DC voltage 10-30 V power supply using supplied power cable. LED’s should start blinking, see “FMP100 LED status”.
  2. Connect device to computer using Micro-USB cable or Bluetooth® connection:
    • Using Micro-USB cable
    • Using Bluetooth®
      • FMP100 Bluetooth® is enabled by default. Turn on Bluetooth® on your PC, then select Add Bluetooth® or other device > Bluetooth®. Choose your device named – “FMP100_last_7_imei_digits”, without LE in the end. Enter default password 5555, press Connect and then select Done.
  3. You are now ready to use the device on your computer.

How to install USB drivers (Windows)

  1. Please download COM port drivers from here.
  2. Extract and run TeltonikaCOMDriver.exe.
  3. Click Next in driver installation window.
  4. In the following window click Install button.
  5. Setup will continue installing the driver and eventually the confirmation window will appear. Click Finish to complete the setup.

Configuration (Windows)

At first FMP100 device will have default factory settings set. These settings should be changed according to the user's needs.
Main configuration can be performed via Teltonika Configurator software. Get the latest FMP100 Configurator version from here. Configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework. Make sure you have the correct version installed.

MS .NET requirements
Operating system MS .NET Framework version Version Link
  • Windows Vista
  • Windows 7
  • Windows 8.1
  • Windows 10
MS .NET Framework 5.0 32 and 64 bit .NET Framework

Downloaded Configurator will be in compressed archive. Extract it and launch Configurator.exe. After launch software language can be changed by clicking Language logo.png in the right bottom corner:

FMB Configurator languag.jpg

Configuration process begins by pressing on connected device:

FMP100-connected.png

After connection to Configurator Status window will be displayed:

FMP100 Beacon-info-FMB1 series.png


Various Status window tabs display information about GNSS, GSM, I/O, Maintenance and etc. FMP100 has one user editable profile, which can be loaded and saved to the device. After any modification of configuration the changes need to be saved to device using Save to device button. Main buttons offer following functionality:

  1. Load from device.png Load from device – loads configuration from device.
  2. Save to device.png Save to device – saves configuration to device.
  3. Load from file.png Load from file – loads configuration from file.
  4. Save to file.png Save to file – saves configuration to file.
  5. Firmware update.png Update firmware – updates firmware on device.
  6. Read records.png Read records – read records from device.
  7. Reboot device.png Reboot device – restarts device.
  8. Reset configuration.png Reset configuration – sets device configuration to default.

Most important configurator section is GPRS – where all your server and GPRS settings can be configured and Data Acquisition – where data acquiring parameters can be configured. More details about FMP100 configuration using Configurator can be found here.

Quick SMS configuration

Default configuration has optimal parameters present to ensure best performance of track quality and data usage.
Quickly set up your device by sending this SMS command to it:

"  setparam 2001:APN;2002:APN_username;2003:APN_password;2004:Domain;2005:Port;2006:0"

GPRS settings:

  • 2001 – APN
  • 2002 – APN username (if there are no APN username, empty field should be left)
  • 2003 – APN password (if there are no APN password, empty field should be left)

Server settings:

  • 2004 – Domain
  • 2005 – Port
  • 2006 – Data sending protocol (0 – TCP, 1 – UDP)

Note: Before SMS text, two space symbols should be inserted.

IOS sms cfg.png
Default configuration settings
Movement and ignition detection:
Accelerometer.png Vehicle movement will be detected by accelerometer Ignition detection-2-2.png Ignition will be detected by vehicle power voltage between 13,2 – 30 V
Device makes a record On Moving if one of these events happen:
300s icon 2.png 300 seconds passes Angle 10 2.png Vehicle turns 10° degrees
Min distance.png Vehicle drives 100 meters Speed delta.png Speed difference between last coordinate and current position is greater than 10 km/h
Device makes a record On Stop if:
1h icon.png 1 hour passes while vehicle is stationary and ignition is off
Records sending to server:
120 s.png If device has made a record it is sent to the server every 120 seconds


After successful SMS configuration, FMP100 device will synchronize time and update records to configured server. Time intervals and default I/O elements can be changed by using Teltonika Configurator or SMS parameters.



Safety information

This message contains information on how to operate FMP100 safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!

  • The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed voltage range is +10..+30V DC.
  • To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible. They show the status of device operation.
  • Before unmounting the device from the vehicle, ignition MUST be OFF.






Precautions

Bw nb.png Do not disassemble the device. If the device is damaged, the power supply cables are not isolated or the isolation is damaged, DO NOT touch the device before unplugging the power supply.
Bw nb.png All wireless data transferring devices produce interference that may affect other devices which are placed nearby.
Bw key.png Please consult representatives of your vehicle model regarding OBD II location on your vehicle. In case you are not sure about proper connection, please consult qualified personnel.
Bw tick.png The programming must be performed using a PC with autonomic power supply.
Bw humidity.png The device is susceptible to water and humidity.
Bw ecute.png Installation and/or handling during a lightning storm is prohibited.
Bw nb.png Teltonika is not responsible for any harm caused by wrong cables used for connection between PC and FMP100.
Bw nb.png WARNING! Do not use FMP100 device if it distracts driver or causes inconvenience due to OBD II placement. Device must not interfere with driver.

https://teltonika.lt/product/FMP100/