Line 4: |
Line 4: |
| __TOC__ | | __TOC__ |
| | | |
− | ==2022.05.26: Base firmware update== | + | ==2024.05.13: Base firmware update== |
− | We would like to inform you about the base firmware update for FMT100 starting from July 25th, 2022. New production firmware version will be 03.27.13.Rev.03 | + | We would like to inform you about the base firmware update for FMT100 starting from June, 2024. New production firmware version will be '''03.29.00.Rev.18''' |
| + | {| class="wikitable" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Change description |
| + | |- |
| + | | style="text-align: left; background: white;" |Change type |
| + | | colspan="2" style="text-align: left; background: white;" |Firmware update |
| + | |- |
| + | | rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description |
| + | | colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: [[FMT100 firmware errata]] |
| + | |- |
| + | | style="text-align: left; background: white;" |Old version: <br> 03.29.00.Rev.13 |
| + | | style="text-align: left; background: white;" |New version: <br> 03.29.00.Rev.18 |
| + | |- |
| + | | style="text-align: left; background: white;" |Change reasons |
| + | | colspan="2" style="text-align: left; background: white;" |FMT100 base firmware version update |
| + | |- |
| + | | style="text-align: left; background: white;" | Product release date |
| + | | colspan="2" style="text-align: left; background: white;" |2024 June |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Affected products |
| + | |- |
| + | | style="width: 221px; text-align: left; background: white;" |Model |
| + | | style="width: 448px; text-align: left; background: white;" |Affected order codes |
| + | | style="width: 448px; text-align: left; background: white;" |Order code changes |
| + | |- |
| + | | style="text-align: left; background: white;" |FMT100 |
| + | | style="text-align: left; background: white;" |Order codes with base Firmware |
| + | | style="text-align: left; background: white;" |New firmware version |
| + | |- |
| + | |} |
| + | {| class="wikitable" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Change impact |
| + | |- |
| + | | style="width: 221px; text-align: left; background: white;" |Risk assessment |
| + | | colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. |
| + | |- |
| + | | style="text-align: left; background: white;" |Suggested implementation plan |
| + | | colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
| + | |- |
| + | |} |
| + | |
| + | ==2023.10.25: GNSS antenna changes== |
| + | |
| + | We would like to inform you about the GNSS antenna change for FMT100 starting from October 2023. |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Change description |
| + | |- |
| + | | style="text-align: left; background: white;" |Change type |
| + | | colspan="2" style="text-align: left; background: white;" |Mechanical part changes |
| + | |- |
| + | | rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description |
| + | |- |
| + | | style="text-align: left; background: white;" |Old version: [[File:FMT35.jpg]] |
| + | <br> Antenna size: 35x35x3 mm |
| + | <br> Center frequency: 1575.42 MHz, 1602 MHz |
| + | <br> VSWR: <1.8 |
| + | <br> Average gain: -1.3 dB |
| + | <br> Return loss: < -14 dB |
| + | | style="text-align: left; background: white;" | New version: [[File:FMT25.jpg]] |
| + | <br> Antenna size: 25x25x4 mm |
| + | <br> Center frequency: 1575.42 MHz, 1602 MHz |
| + | <br> VSWR: <1.2 |
| + | <br> Average Gain: -1.2 dB |
| + | <br> Return loss < -29 dB |
| + | |- |
| + | | style="text-align: left; background: white;" |Change reasons |
| + | | colspan="2" style="text-align: left; background: white;" | Standardization of GNSS antennas throughout device portfolio and manufacturing efficiency improvements |
| + | |
| + | |- |
| + | | style="text-align: left; background: white;" |Product release date |
| + | | colspan="2" style="text-align: left; background: white;" |October 2023 |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Affected products |
| + | |- |
| + | | style="width: 221px; text-align: left; background: white;" |Model |
| + | | style="width: 448px; text-align: left; background: white;" |Affected order codes |
| + | | style="width: 448px; text-align: left; background: white;" |Order code changes |
| + | |- |
| + | | style="text-align: left; background: white;" |FMT100 |
| + | | style="text-align: left; background: white;" |FMT100******* order codes |
| + | | style="text-align: left; background: white;" |No changes |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Change impact |
| + | |- |
| + | | style="width: 221px; text-align: left; background: white;" |Risk assessment |
| + | | colspan="2" style="width: 908px; text-align: left; background: white;" |Since the change of the GNSS antenna is visible visually on PCB, in order to avoid problems at the customs of certain countries, we suggest informing the relevant authorities about the change of the GNSS antenna as soon as possible. The new GNSS antenna provides an equivalent track quality and performance level, as verified through testing. Testing results: |
| + | {| class="wikitable" style="text-align:center; background-color:#ffffff;" |
| + | |- style="font-weight:bold;" |
| + | ! style="color:#000000;" | Device |
| + | ! Antenna |
| + | ! Mounting conditions* |
| + | ! style="color:#000000;" | Avg. Difference<br /> from precise track** [m] |
| + | |- |
| + | | style="color:#000000;" | FMT100_162 |
| + | | New |
| + | | Excellent |
| + | | style="color:#000000;" | 2,59 |
| + | |- |
| + | | style="color:#000000;" | FMT100_745 |
| + | | Old |
| + | | style="background-color:#FFF;" | Excellent |
| + | | style="color:#000000;" | 4,43<br /> |
| + | |- |
| + | | style="color:#000000;" | FMT100_170 |
| + | | New |
| + | | Good |
| + | | style="color:#000000;" | 3,45 |
| + | |- |
| + | | style="color:#000000;" | FMT100_937 |
| + | | Old |
| + | | Good |
| + | | style="color:#000000;" | 4,68 |
| + | |- |
| + | | style="color:#000000;" | FMT100_238 |
| + | | New |
| + | | Normal |
| + | | style="color:#000000;" | 3,93 |
| + | |- |
| + | | style="color:#000000;" | FMT100_705 |
| + | | Old |
| + | | Normal |
| + | | style="color:#000000;" | 4,92 |
| + | |- |
| + | | style="color:#000000;" | FMT100_071 |
| + | | New |
| + | | style="background-color:#FFF;" | Poor |
| + | | style="color:#000000;" | 4,98 |
| + | |- |
| + | | style="color:#000000;" | FMT100_638 |
| + | | Old |
| + | | Poor |
| + | | style="color:#000000;" | 5,05 |
| + | |} |
| + | |
| + | '''*'''''Mounting conditions'' - device position under the hood from a poor location (thick metal layer above device) to an excellent location (thin metal layer above device) <br> |
| + | '''**'''''Avg. Difference from precise track'' - measured by comparing positioning data from devices and RTK (Real-time kinematic positioning) system data which is considered precise data. The smaller avg. difference from precise track, means better track quality. |
| + | |
| + | |- |
| + | | style="text-align: left; background: white;" |Suggested implementation plan |
| + | | colspan="2" style="text-align: left; background: white;" |No implementation plan needed |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | |- |
| + | |} |
| + | |
| + | ==2022.08.01: Base firmware update== |
| + | We would like to inform you about the base firmware update for FMT100 starting from August 1st, 2022. New production firmware version will be 03.27.13.Rev.03 |
| {| class="wikitable" | | {| class="wikitable" |
| |+ | | |+ |
Line 23: |
Line 188: |
| |- | | |- |
| | style="text-align: left; background: white;" | Product release date | | | style="text-align: left; background: white;" | Product release date |
− | | colspan="2" style="text-align: left; background: white;" |2022 July | + | | colspan="2" style="text-align: left; background: white;" |2022 August |
| |- | | |- |
| |} | | |} |