==2024.05.24: PCB changes==
 +
We would like to inform you that starting from May, 2024, there will be changes in the PCB's modification of our FMB120 devices. These changes affect FMB110, FMB120, FMB130 and FMB230 devices.
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Mechanical part changes
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |The PCB shape has been modified for the following devices: FMB110, FMB120, FMB130, and FMB230. These changes will be implemented during the upcoming factory update.
 +
#Components which were too close (less than 1.5mm) to the testpoints were moved away to comply with this requirement.
 +
#Overvoltage protection mosfet changed to 2x mosfets with smaller footprint.
 +
#Accelerometer LIS2DH12 was moved to top layer and closer to existing LIS3DH accelerometer.
 +
#Positioning hole was moved from LTE to BLE antenna.
 +
#Components from GNSS antenna feed point were moved away to comply with manufacturing requirements.
 +
#Main fuse moved to TOP layer.
 +
#Added 1 positioning hole close to GNSS antenna.
 +
#Positioning hole near LED's was removed.
 +
|-
 +
| style="text-align: left; background: white;" |Old Version: [[File:OLD front.png|center|250px]] [[File:OLD back.png|center|250px]]                                                         
 +
| style="text-align: left; background: white;" |New Version: [[File:NEW front.png|center|250px]] [[File:NEW back.png|center|250px]]
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |
 +
The PCB shape in the afore-mentioned devices is updated to streamline the manufacturing process, making it more efficient.
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2024 May
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB120
 +
| style="text-align: left; background: white;" |FMB120******* order codes
 +
| style="text-align: left; background: white;" |New firmware version
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
 +
==2024.05.13: Base firmware update==
 +
We would like to inform you about the base firmware update for FMB120 starting from June, 2024. New production firmware version will be '''03.29.00.Rev.18'''
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: [[FMB120 firmware errata]]
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> 03.29.00.Rev.13
 +
| style="text-align: left; background: white;" |New version: <br> 03.29.00.Rev.18
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMB120 base firmware version update
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2024 June
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB120
 +
| style="text-align: left; background: white;" |Order codes with base Firmware
 +
| style="text-align: left; background: white;" |PCB's mechanical part changes
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" | No risk factors encountered with this change.
 +
Suggested implementation plan: Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
 +
|-
 +
| style="text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
| colspan="2" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
 +
|-
 +
|}
 +
 
==2023.11.27: Modifications of PCB shape ==
 
==2023.11.27: Modifications of PCB shape ==
   Line 176: Line 283:  
| style="text-align: left; background: white;" |Suggested implementation plan
 
| style="text-align: left; background: white;" |Suggested implementation plan
 
| colspan="2" style="text-align: left; background: white;" | 1. We highly recommend updating the spec.firmware`s with the latest version in order to support new changes on FMB120 hardware.  
 
| colspan="2" style="text-align: left; background: white;" | 1. We highly recommend updating the spec.firmware`s with the latest version in order to support new changes on FMB120 hardware.  
2. For further assistance, including the updates of special firmware versions, please contact your Teltonika Telematics sales manager or fill query on VIP HelpDesk.
+
2. For further assistance, including the updates of special firmware versions, please contact your Teltonika Telematics sales manager or fill query on HelpDesk.
    
|-
 
|-