Difference between revisions of "FM36 setdigout"
From Wiki Knowledge Base | Teltonika GPS
Simkunas.ma (talk | contribs) |
Simkunas.ma (talk | contribs) |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
− | Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row for OUT1 and OUT2 values. | + | Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row for OUT1 and OUT2 values. |
+ | |||
+ | *Example: ‘setdigout 01 0 5’ will set OUT2 to high level for 5 seconds, while OUT1 to low level.<br /> | ||
+ | To ignore one digital output value and make ON/OFF state only to another digital output in place of 0 or 1 values, “?” must be used.<br /> | ||
+ | *Example: ‘setdigout ?1’ will set OUT2 to high level for indefinite period of time while OUT1 remains as it was set before. |
Latest revision as of 12:23, 1 June 2018
Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row for OUT1 and OUT2 values.
- Example: ‘setdigout 01 0 5’ will set OUT2 to high level for 5 seconds, while OUT1 to low level.
To ignore one digital output value and make ON/OFF state only to another digital output in place of 0 or 1 values, “?” must be used.
- Example: ‘setdigout ?1’ will set OUT2 to high level for indefinite period of time while OUT1 remains as it was set before.