Difference between revisions of "FMB962 General description"

From Wiki Knowledge Base | Teltonika GPS
Line 5: Line 5:
 
==Basic characteristics==
 
==Basic characteristics==
  
{{Template:FMB964_Basic_characteristics}}
+
{{Template:FMB962_Basic_characteristics}}
  
 
==Technical features==
 
==Technical features==

Revision as of 10:43, 24 October 2018

Main Page > EOL Products > FMB962 > FMB962 Manual > FMB962 General description

FMB964 is a tracking terminal with GNSS and GSM connectivity, which is able to collect device coordinates and transfer them via GSM network to a server. This device is perfectly suitable for applications, which require the location acquirement of remote objects.

Package contents

The FMB964 device is supplied to the customer in a cardboard box containing all the equipment that is necessary for operation. The package contains:

  • Already implemented FMB964 device into case;
  • Top and bottom device cover parts;
  • Input and output power supply cable with a 1x5 connection pins, which is already installed into device.
  • 1800 mAh Li Po rechargeable 3.7 V battery

Basic characteristics

Template:FMB962 Basic characteristics

Technical features

Part name Physical specification
Navigation indication LED
Modem indication LED
Socket Soldered inner socket
USB Micro USB socket
Technical details
2 W max.
Current consumption at 12 V
GPRS: average 60 mA rms
Nominal: average 27 rms
GPS sleep: average 3.27 mA
Deep Sleep: average 3 mA
Online Deep Sleep: average 2.89 mA
Ultra Deep Sleep: average 1.60 mA
Rated current: 250 mA
Battery charge current Average 140 mA
Operating temperature -25..+55 °C
Storage temperature -20..+45 °C
Storage relative humidity 5..85% (no condensation)

Dimension drawing:

npne

Technical information about internal battery

Internal back-up battery Battery voltage (V) Nominal capacity (mAh) Power (Wh) Charging temperature (°C)
Li-Po rechargeable battery 3.4~4.1 1800 6.21 – 7.38 0 – 45

Batteries are covered by 6 month warranty support.

Bw nb.png CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Bw disposal.png Battery should not be disposed of into general household waste.
Bring damaged or worn-out batteries to your local recycling center or dispose them into a battery recycle bin commonly found in supermarkets.

Electrical characteristics


Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage:
Supply Voltage
(Recommended Operating Conditions)
6 30 V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF) 120 µA
Drain current
(Digital Output ON, Recommended Operating Conditions)
0.1 0.5 A
Digital Input: 300
Digital Output (Open Drain grade):
Input resistance (DIN1) 47
Input voltage
(Recommended Operating Conditions)
0 Supply voltage V
Input Voltage threshold (DIN1) 4 V
Analog Input:
Input voltage
(Recommended Operating Conditions)
0 30 V
Input resistance 150
Measurement error on 12 V 3 %
Additional error on 12 V 360 mV
Measurement error on 30 V 3 %
Additional error on 30 V 900 mV


Alert.png
Analog Input error margin can increase if temperature varies.

Absolute maximum ratings

Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage
(Absolute Maximum Ratings)
-32 +32 V
Drain-Source clamp threshold voltage
(Absolute Maximum Ratings), (Idrain = 2 mA)
+36 V
Digital Input Voltage
(Absolute Maximum Ratings)
-32 +32 V
Analog Input Voltage
(Absolute Maximum Ratings)
-32 +32 V