Template:FMB Bluetooth settings: Difference between revisions
No edit summary |
Kudalevas.da (talk | contribs) No edit summary |
||
Line 41: | Line 41: | ||
==Auto Connect to External Device== | ==Auto Connect to External Device== | ||
[[Image: | [[Image:FMB1YX_Bluetooh_Auto_connect.png|{{{auto_connect|size}}}|right]] | ||
Auto connection functionality configures {{{model|FMB1YX}}} as master device, which allows connecting {{{model|FMB1YX}}} to an external device. {{{model|FMB1YX}}} currently supports these modes: | Auto connection functionality configures {{{model|FMB1YX}}} as master device, which allows connecting {{{model|FMB1YX}}} to an external device. {{{model|FMB1YX}}} currently supports these modes: | ||
Revision as of 11:48, 26 February 2020
General functionality
General functionality configures Bluetooth to work in slave mode. This mode allows any external device to connect to FMB1YX.
Parameter BT Radio allows enabling or disabling Bluetooth. There are three different settings:
- Disabled – Bluetooth functionality will be disabled.
- Enable (hidden) – Bluetooth functionality will be enabled, external devices will be able to connect to FMB1YX, but no devices will be able to detect it.
- Enable (visible) – Bluetooth functionality will be enabled and any external device will be able to detect and connect to FMB1YX.
It is possible to configure the Local name of the device, as well as the Local PIN, which will be used when trying to pair with the FMB1YX device. There are two different parameters:
- Local Name parameter lets user declare a visible name of FMB1YX to external devices.
- Local PIN parameter lets user configure Bluetooth PIN of FMB1YX device.
The FMB1YX supports composed Bluetooth Local names, which allows the user to have a predefined number of IMEI digits at the end of the device name. The format of the composed Bluetooth name looks like this:
Device name + %imeiX
X - how many digits will be taken from IMEI to show in Local name, digits will be taken from the end of IMEI. Minimum value of X is 1 and the Maximum value is 15.
Example:
If the configured Local Name parameter is "FMB_120_%imei7" and the IMEI of the device is 352093089520901, name will be displayed as FMB_120_9520901 (whether "_LE" is added at the end depends on whether device supports BLE or not. The full name of the device, which supports BLE would be FMB_120_9520901_LE).
If the Local Name is written incorrectly, the Bluetooth name of the device will be broadcasted as it is. An example can be seen below.
Example:
If the configured Local Name parameter is "FMB_120_%ime7" devices name will be broadcasted as FMB_120_%ime7 or if wrong X will be configured, for example "FMB_120_%imei20" devices name will broadcasted as FMB_120_%imei20.
The Composed Bluetooth name is supported from 03.25.05 firmware version. |
FMB1YX Bluetooth has several different Security Modes:
- PIN only – only Local PIN will be reacquired to complete connection to FMB1YX.
- PIN + MAC list – PIN and Authorized Devices MAC List will be checked against to allow connection to FMB1YX. If the external device MAC ID is in the list and correct Local PIN is entered then connection will be established, otherwise FMB1YX will reject connection.
- MAC list only – only Authorized Devices MAC List will be checked when trying to connect to FMB1YX. If external device MAC ID is in the list then connection will be established, otherwise FMB1YX will reject connection.
- None – neither Local PIN nor Authorized Device MAC List will be checked.
Auto Connect to External Device
Auto connection functionality configures FMB1YX as master device, which allows connecting FMB1YX to an external device. FMB1YX currently supports these modes:
- None – disables auto connection functionality.
- Data Link – BT Data link mode is enabled by Configurator Data Link parameter: when Data Link is configured and FMB has a link with the server, paired device can send messages via Bluetooth SPP profile directly to the server. Messages will be encoded by Codec12.
- Inateck Scanner – FMB1YX automatically connects to Inateck BT Barcode Scanner BCST-70 and will be ready to receive data (coded in barcode). Scanner must be configured for using “ENTER” as suffix. FMB1YX supports online and inventory mode. A new record will be generated on every data portion received from scanner via SPP. Data will be stored with AVL ID 264, variable data length, max length is 32 bytes. Note: Added from FW version 03.16.00.Rev.00+
- User ID - This mode makes FMB1YX connect automatically to a device and stores its BT MAC address in I/O element User ID (I/O ID: 50520). This is used for driver authentication. If there‘s no connection, the I/O element value is set to 0.
FMB1YX supports ONE connection at a time. FMB1YX can see up to 10 available devices. If there are more than 10 devices, the list may change with each new scan. |
External Name parameter works as a substring, which allows user to enter a part of the full external device name. For example, if external device name is "HandsFreeHeadset" and user enters "HandsFree" in External Name parameter window, then FMB1YX will be allowed to connect to an external device named "HandsFreeHeadset".