Difference between revisions of "Template:FMX640 AVL ID"
Line 444: | Line 444: | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |0,1 | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |0,1 | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | ||
− | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" |Degrees ( °C ), -55 - +115, if 3000 – | + | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" |Degrees ( °C ), -55 - +115, |
+ | if 850 – Sensor not ready <br> | ||
+ | if 2000 – Value read error <br> | ||
+ | if 3000 – Not connected <br> | ||
+ | if 4000 – ID failed <br> | ||
+ | if 5000 – same as 850 | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | ||
Line 457: | Line 462: | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |0,1 | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |0,1 | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | ||
− | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" |Degrees ( °C ), -55 - +115, if 3000 – | + | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" |Degrees ( °C ), -55 - +115, |
+ | if 850 – Sensor not ready <br> | ||
+ | if 2000 – Value read error <br> | ||
+ | if 3000 – Not connected <br> | ||
+ | if 4000 – ID failed <br> | ||
+ | if 5000 – same as 850 | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | ||
Line 470: | Line 480: | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |0,1 | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |0,1 | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | ||
− | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" |Degrees ( °C ), -55 - +115, if 3000 – | + | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" |Degrees ( °C ), -55 - +115, |
+ | if 850 – Sensor not ready <br> | ||
+ | if 2000 – Value read error <br> | ||
+ | if 3000 – Not connected <br> | ||
+ | if 4000 – ID failed <br> | ||
+ | if 5000 – same as 850 | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | ||
Line 483: | Line 498: | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |0,1 | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |0,1 | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | ||
− | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" |Degrees ( °C ), -55 - +115, if 3000 – | + | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" |Degrees ( °C ), -55 - +115, |
+ | if 850 – Sensor not ready <br> | ||
+ | if 2000 – Value read error <br> | ||
+ | if 3000 – Not connected <br> | ||
+ | if 4000 – ID failed <br> | ||
+ | if 5000 – same as 850 | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | ||
Line 800: | Line 820: | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" | | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" | | ||
− | Degrees ( °C ), -55 - +115, <br> if 3000 – | + | Degrees ( °C ), -55 - +115,<br> |
+ | |||
+ | if 850 – Sensor not ready <br> | ||
+ | if 2000 – Value read error <br> | ||
+ | if 3000 – Not connected <br> | ||
+ | if 4000 – ID failed <br> | ||
+ | if 5000 – same as 850 | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | ||
Line 825: | Line 851: | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |°C | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" | | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: left;" | | ||
− | Degrees ( °C ), -55 - +115, <br> if 3000 – | + | Degrees ( °C ), -55 - +115, <br> |
+ | |||
+ | if 850 – Sensor not ready <br> | ||
+ | if 2000 – Value read error <br> | ||
+ | if 3000 – Not connected <br> | ||
+ | if 4000 – ID failed <br> | ||
+ | if 5000 – same as 850 | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |[[FMB640]]<br>[[FMC640]]<br>[[FMM640]] | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; background: white; text-align: center;" |Permanent I/O elements |
Revision as of 06:48, 20 October 2020
Permanent I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
239 | Ignition | 1 | Unsigned | 0 | 1 | - | - |
0 – Ignition Off |
Permanent I/O elements | |
240 | Movement | 1 | Unsigned | 0 | 1 | - | - |
0 – Movement Off |
Permanent I/O elements | |
22 | Data Mode | 1 | Unsigned | 0 | 5 | - | - |
0 – Home On Stop |
Permanent I/O elements | |
21 | GSM Signal | 1 | Unsigned | 0 | 5 | - | - | Value in range 1-5 | FMB640 FMC640 FMM640 |
Permanent I/O elements |
200 | Sleep Mode | 1 | Unsigned | 0 | 1 | - | - |
Normal mode |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
71 | GNSS Status | 1 | Unsigned | 0 | 5 | - | - |
0 - GNSS OFF |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
181 | GNSS PDOP | 2 | Unsigned | 0 | 500 | - | - | Probability | FMB640 FMC640 FMM640 |
Permanent I/O elements |
182 | GNSS HDOP | 2 | Unsigned | 0 | 500 | - | - | Probability | FMB640 FMC640 FMM640 |
Permanent I/O elements |
66 | External Voltage | 2 | Unsigned | 0 | 30000 | 0,001 | mV | Voltage, mV | FMB640 FMC640 FMM640 |
Permanent I/O elements |
24 | Speed | 2 | Unsigned | 0 | 350 | - | km/h | Value, km/h | FMB640 FMC640 FMM640 |
Permanent I/O elements |
205 | GSM Cell ID | 4 | Unsigned | 0 | 4294967295 | - | - | GSM base station ID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
206 | GSM Area Code | 2 | Unsigned | 0 | 65535 | - | - | Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. | FMB640 FMC640 FMM640 |
Permanent I/O elements |
67 | Battery Voltage | 2 | Unsigned | 0 | 30000 | 0,001 | mV | Voltage, mV | FMB640 FMC640 FMM640 |
Permanent I/O elements |
68 | Battery Current | 2 | Unsigned | 0 | 2400 | - | mA | Current, mA | FMB640 FMC640 FMM640 |
Permanent I/O elements |
241 | Active GSM Operator | 4 | Unsigned | 0 | 4294967295 | - | - | Currently used GSM Operator code | FMB640 FMC640 FMM640 |
Permanent I/O elements |
199 | Trip Odometer | 4 | Unsigned | 0 | 4294967295 | - | m | Trip Odometer value in meters | FMB640 FMC640 FMM640 |
Permanent I/O elements |
216 | Total Odometer | 4 | Unsigned | 0 | 4294967295 | - | m | Total Odometer value in meters | FMB640 FMC640 FMM640 |
Permanent I/O elements |
1 | Digital Input 1 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB640 FMC640 FMM640 |
Permanent I/O elements |
9 | Analog Input 1 | 2 | Unsigned | 0 | 30000 | 0,001 | V | Voltage, V | FMB640 FMC640 FMM640 |
Permanent I/O elements |
179 | Digital Output 1 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB640 FMC640 FMM640 |
Permanent I/O elements |
236 | Axis X | 2 | Signed | -8000 | 8000 | - | mG | X axis value, mG | FMB640 FMC640 FMM640 |
Permanent I/O elements |
237 | Axis Y | 2 | Signed | -8000 | 8000 | - | mG | Y axis value, mG | FMB640 FMC640 FMM640 |
Permanent I/O elements |
238 | Axis Z | 2 | Signed | -8000 | 8000 | - | mG | Z axis value, mG | FMB640 FMC640 FMM640 |
Permanent I/O elements |
219 | CCID Part1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Value of SIM ICCID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
220 | CCID Part2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Value of SIM ICCID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
221 | CCID Part3 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Value of SIM ICCID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
144 | SD Status | 1 | Unsigned | 0 | 1 | - | - | Logic: 0 – not present, 1 – present | FMB640 FMC640 FMM640 |
Permanent I/O elements |
2 | Digital Input 2 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB640 FMC640 FMM640 |
Permanent I/O elements |
3 | Digital Input 3 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB640 FMC640 FMM640 |
Permanent I/O elements |
10 | Analog Input 2 | 2 | Unsigned | 0 | 30000 | 0,001 | V | Voltage, V | FMB640 FMC640 FMM640 |
Permanent I/O elements |
180 | Digital Output 2 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB640 FMC640 FMM640 |
Permanent I/O elements |
72 | Dallas Temperature 1 | 2 | Signed | -550 | 1150 | 0,1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
73 | Dallas Temperature 2 | 2 | Signed | -550 | 1150 | 0,1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
74 | Dallas Temperature 3 | 2 | Signed | -550 | 1150 | 0,1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
75 | Dallas Temperature 4 | 2 | Signed | -550 | 1150 | 0,1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
62 | Dallas Temperature ID 1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
63 | Dallas Temperature ID 2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
64 | Dallas Temperature ID 3 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
65 | Dallas Temperature ID 4 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
78 | iButton | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | iButton ID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
207 | RFID | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | RFID ID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
201 | LLS 1 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS232 in kvants or liters | FMB640 FMC640 FMM640 |
Permanent I/O elements |
202 | LLS 1 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS232 in degrees Celsius | FMB640 FMC640 FMM640 |
Permanent I/O elements |
203 | LLS 2 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS232 in kvants or liters | FMB640 FMC640 FMM640 |
Permanent I/O elements |
204 | LLS 2 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS232 in degrees Celsius | FMB640 FMC640 FMM640 |
Permanent I/O elements |
210 | LLS 3 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS232 in kvants or liters | FMB640 FMC640 FMM640 |
Permanent I/O elements |
211 | LLS 3 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS232 in degrees Celsius | FMB640 FMC640 FMM640 |
Permanent I/O elements |
212 | LLS 4 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS232 in kvants or liters | FMB640 FMC640 FMM640 |
Permanent I/O elements |
213 | LLS 4 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS232 in degrees Celsius | FMB640 FMC640 FMM640 |
Permanent I/O elements |
214 | LLS 5 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS232 in kvants or liters | FMB640 FMC640 FMM640 |
Permanent I/O elements |
215 | LLS 5 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS232 in degrees Celsius | FMB640 FMC640 FMM640 |
Permanent I/O elements |
178 | Network Type | 1 | Unsigned | 0 | 1 | - | - |
0 - 3G |
FMC640 FMM640 |
Permanent I/O elements |
4 | Digital Input 4 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB640 FMC640 FMM640 |
Permanent I/O elements |
50 | Digital Output 3 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB640 FMC640 FMM640 |
Permanent I/O elements |
51 | Digital Output 4 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB640 FMC640 FMM640 |
Permanent I/O elements |
11 | Analog Input 3 | 2 | Unsigned | 0 | 30000 | 0,001 | V | Voltage, V | FMB640 FMC640 FMM640 |
Permanent I/O elements |
245 | Analog Input 4 | 2 | Unsigned | 0 | 30000 | 0,001 | V | Voltage, V | FMB640 FMC640 FMM640 |
Permanent I/O elements |
70 | PCB Temperature | 2 | Signed | -550 | 1150 | 0,1 | °C | Degrees ( °C ) | FMB640 FMC640 FMM640 |
Permanent I/O elements |
5 | Dallas Temperature ID 5 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
6 | Dallas Temperature 5 | 2 | Signed | -550 | 1150 | 0,1 | °C |
Degrees ( °C ), -55 - +115, if 850 – Sensor not ready |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
7 | Dallas Temperature ID 6 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | FMB640 FMC640 FMM640 |
Permanent I/O elements |
8 | Dallas Temperature 6 | 2 | Signed | -550 | 1150 | 0,1 | °C |
Degrees ( °C ), -55 - +115, if 850 – Sensor not ready |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
76 | Fuel Counter | 4 | Unsigned | 0 | 4294967295 | - | - | Difference of generated impulses on two signal lines | FMB640 FMC640 FMM640 |
Permanent I/O elements |
217 | RFID COM2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | RFID ID on COM2 | FMB640 FMC640 FMM640 |
Permanent I/O elements |
218 | IMSI | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | International mobile subscriber identity | FMB640 FMC640 FMM640 |
Permanent I/O elements |
224 | Ultrasonic Fuel Level 1 | 2 | Signed | -15 | 32767 | 0,1 | mm | FMB640 FMC640 FMM640 |
Permanent I/O elements | |
225 | Ultrasonic Fuel Level 2 | 2 | Signed | -15 | 32767 | 0,1 | mm | FMB640 FMC640 FMM640 |
Permanent I/O elements | |
208 | Ultrasonic Software Status 1 | 1 | Unsigned | 0 | 255 | - | - |
0 – Software – Normal |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
209 | Ultrasonic Software Status 2 | 1 | Unsigned | 0 | 255 | - | - |
Values are identical to Ultrasonic Software Status 1 |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
390 | External Sensor Temperature 0 | 2 | Signed | -32768 | 32767 | - | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Permanent I/O elements |
391 | External Sensor Temperature 1 | 2 | Signed | -32768 | 32767 | - | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Permanent I/O elements |
392 | External Sensor Temperature 2 | 2 | Signed | -32768 | 32767 | - | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Permanent I/O elements |
393 | External Sensor Temperature 3 | 2 | Signed | -32768 | 32767 | - | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Permanent I/O elements |
394 | External Sensor Temperature 4 | 2 | Signed | -32768 | 32767 | - | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Permanent I/O elements |
395 | External Sensor Temperature 5 | 2 | Signed | -32768 | 32767 | - | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Permanent I/O elements |
FMS elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
79 | Brake Switch | 1 | Unsigned | 0 | 1 | - | - |
0 - Pedal released |
FMB640 FMC640 FMM640 |
FMS elements |
80 | Wheel Based Speed | 4 | Unsigned | 0 | 65536 | - | km/h | FMB640 FMC640 FMM640 |
FMS elements | |
81 | Cruise Control Active | 1 | Unsigned | 0 | 1 | - | - |
0 - Switched off |
FMB640 FMC640 FMM640 |
FMS elements |
82 | Clutch Switch | 1 | Unsigned | 0 | 1 | - | - |
0 - Pedal released |
FMB640 FMC640 FMM640 |
FMS elements |
83 | PTO State | 1 | Unsigned | 0 | 1 | - | - |
0 - Off/disabled |
FMB640 FMC640 FMM640 |
FMS elements |
84 | Acceleration Pedal Position | 4 | Unsigned | 0 | 102 | - | % | FMB640 FMC640 FMM640 |
FMS elements | |
85 | Engine Current Load | 1 | Unsigned | 0 | 125 | - | % | FMB640 FMC640 FMM640 |
FMS elements | |
86 | Engine Total Fuel Used | 4 | Unsigned | 0 | 2105540607 | - | l | Value in liters, L | FMB640 FMC640 FMM640 |
FMS elements |
87 | Fuel Level | 4 | Unsigned | 0 | 102 | - | % | FMB640 FMC640 FMM640 |
FMS elements | |
88 | Engine Speed | 4 | Unsigned | 0 | 8032 | - | rpm | FMB640 FMC640 FMM640 |
FMS elements | |
89 | Axle weight 1 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
90 | Axle weight 2 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
91 | Axle weight 3 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
92 | Axle weight 4 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
93 | Axle weight 5 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
94 | Axle weight 6 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
95 | Axle weight 7 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
96 | Axle weight 8 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
97 | Axle weight 9 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
98 | Axle weight 10 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
99 | Axle weight 11 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
100 | Axle weight 12 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
101 | Axle weight 13 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
102 | Axle weight 14 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
103 | Axle weight 15 | 4 | Unsigned | 0 | 32766 | - | kg | FMB640 FMC640 FMM640 |
FMS elements | |
104 | Engine Total Hours Of Operation | 4 | Unsigned | 0 | 214748364 | - | h | FMB640 FMC640 FMM640 |
FMS elements | |
110 | Diagnostics Supported | 1 | Unsigned | 0 | 3 | - | - |
0 - Diagnostics is not supported |
FMB640 FMC640 FMM640 |
FMS elements |
113 | Service Distance | 4 | Signed | -160635 | 167040 | - | km | FMB640 FMC640 FMM640 |
FMS elements | |
122 | Direction Indication | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
FMS elements | |
123 | Tachograph Performance | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
FMS elements | |
124 | Handling Info | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
FMS elements | |
125 | System Event | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
FMS elements | |
127 | Engine Coolant Temperature | 1 | Signed | -40 | 210 | - | °C | FMB640 FMC640 FMM640 |
FMS elements | |
128 | Ambient Air Temperature | 2 | Signed | -273 | 1770 | - | °C | FMB640 FMC640 FMM640 |
FMS elements | |
135 | Fuel Rate | 4 | Unsigned | 0 | 3212 | - | l/h | FMB640 FMC640 FMM640 |
FMS elements | |
136 | Instantaneous Fuel Economy | 4 | Unsigned | 0 | 125 | - | km/l | FMB640 FMC640 FMM640 |
FMS elements | |
137 | PTO Drive Engagement | 1 | Unsigned | 0 | 3 | - | - |
0 - No PTO drive is engaged |
FMB640 FMC640 FMM640 |
FMS elements |
138 | High Resolution Engine Total Fuel Used | 4 | Unsigned | 0 | 4211081.215 | - | l or ml | Resolution in l or ml depending on the FMS fuel settings (item id 121) | FMB640 FMC640 FMM640 |
FMS elements |
139 | Gross Combination Vehicle Weight | 2 | Unsigned | 0 | 642550 | - | kg | The total weight of the truck and all attached trailers. | FMB640 FMC640 FMM640 |
FMS elements |
10348 | Fuel level 2 | 4 | Unsigned | 0 | 100 | - | % | This parameter shows fuel level in secondary tank (if fuel type is different then currently used fuel) | FMB640 FMC640 FMM640 |
FMS elements |
10349 | MIL indicator | 1 | Unsigned | 0 | 100 | - | - |
0 - OFF |
FMB640 FMC640 FMM640 |
FMS elements |
10428 | Tell Tale 0 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | IO element describes Tell Tale Block ID message received from Block ID 0 in Hexadecimal format. | FMB640 FMC640 FMM640 |
FMS elements |
10429 | Tell Tale 1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | IO element describes Tell Tale Block ID message received from Block ID 1 in Hexadecimal format. | FMB640 FMC640 FMM640 |
FMS elements |
10430 | Tell Tale 2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | IO element describes Tell Tale Block ID message received from Block ID 2 in Hexadecimal format. | FMB640 FMC640 FMM640 |
FMS elements |
10431 | Tell Tale 3 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | IO element describes Tell Tale Block ID message received from Block ID 3 in Hexadecimal format. | FMB640 FMC640 FMM640 |
FMS elements |
CAN adapters elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
30 | Vehicle Speed | 1 | Unsigned | 0 | 255 | - | km/h | Value in km/h | FMB640 FMC640 FMM640 |
CAN adapters elements |
31 | Accelerator Pedal Position | 1 | Unsigned | 0 | 255 | 0,1 | % | Value in persentages, % | FMB640 FMC640 FMM640 |
CAN adapters elements |
33 | Fuel Consumed | 4 | Unsigned | 0 | 2147483647 | 0,1 | l | Value in liters, L | FMB640 FMC640 FMM640 |
CAN adapters elements |
34 | Fuel Level Liters | 2 | Unsigned | 0 | 65535 | 0,1 | l | Value in liters, L | FMB640 FMC640 FMM640 |
CAN adapters elements |
35 | Engine RPM | 2 | Unsigned | 0 | 16384 | - | rpm | Value in rounds per minute, rpm | FMB640 FMC640 FMM640 |
CAN adapters elements |
36 | Total Mileage | 4 | Unsigned | 0 | 4294967295 | - | m | Value in meters, m | FMB640 FMC640 FMM640 |
CAN adapters elements |
37 | Fuel Level Percent | 1 | Unsigned | 0 | 255 | 0,1 | % | Value in percentages, % | FMB640 FMC640 FMM640 |
CAN adapters elements |
143 | Door Status | 2 | Unsigned | 0 | 16128 | - | - |
Min – 0, Max – 16128 |
FMB640 FMC640 FMM640 |
CAN adapters elements |
12 | Program Number | 4 | Unsigned | 0 | 999 | - | - | Value: Min – 0, Max – 999 | FMB640 FMC640 FMM640 |
CAN adapters elements |
13 | Module ID | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Module ID | FMB640 FMC640 FMM640 |
CAN adapters elements |
14 | Engine Worktime | 4 | Unsigned | 0 | 16777215 | - | min | Engine work time in minutes | FMB640 FMC640 FMM640 |
CAN adapters elements |
15 | Engine Worktime (counted) | 4 | Unsigned | 0 | 16777215 | - | min | Total Engine work time in minutes | FMB640 FMC640 FMM640 |
CAN adapters elements |
16 | Total Mileage (counted) | 4 | Unsigned | 0 | 4294967295 | - | m | Total Vehicle Mileage, m | FMB640 FMC640 FMM640 |
CAN adapters elements |
17 | Fuel Consumed (counted) | 4 | Unsigned | 0 | 2147483647 | 0,1 | l | Total Fuel Consumed, l | FMB640 FMC640 FMM640 |
CAN adapters elements |
18 | Fuel Rate | 2 | Unsigned | 0 | 32768 | 0,1 | l/h | Fuel Rata, l/h | FMB640 FMC640 FMM640 |
CAN adapters elements |
19 | AdBlue Level Percent | 1 | Unsigned | 0 | 255 | 0,1 | % | AdBlue, % | FMB640 FMC640 FMM640 |
CAN adapters elements |
20 | AdBlue Level Liters | 2 | Unsigned | 0 | 65535 | 0,1 | l | AdBlue level, L | FMB640 FMC640 FMM640 |
CAN adapters elements |
23 | Engine Load | 1 | Unsigned | 0 | 130 | - | % | Engine load, % | FMB640 FMC640 FMM640 |
CAN adapters elements |
25 | Engine Temperature | 2 | Signed | -600 | 1270 | 0,1 | °C | Engine Temperature, °C | FMB640 FMC640 FMM640 |
CAN adapters elements |
26 | Axle 1 Load | 2 | Unsigned | 0 | 32768 | - | kg | Axle 1 load, kg | FMB640 FMC640 FMM640 |
CAN adapters elements |
27 | Axle 2 Load | 2 | Unsigned | 0 | 32768 | - | kg | Axle 2 load, kg | FMB640 FMC640 FMM640 |
CAN adapters elements |
28 | Axle 3 Load | 2 | Unsigned | 0 | 32768 | - | kg | Axle 3 load, kg | FMB640 FMC640 FMM640 |
CAN adapters elements |
29 | Axle 4 Load | 2 | Unsigned | 0 | 32768 | - | kg | Axle 4 load, kg | FMB640 FMC640 FMM640 |
CAN adapters elements |
32 | Axle 5 Load | 2 | Unsigned | 0 | 32768 | - | kg | Axle 5 load, kg | FMB640 FMC640 FMM640 |
CAN adapters elements |
38 | Control State Flags | 4 | Unsigned | 0 | 4294967295 | - | - | Control state flags | FMB640 FMC640 FMM640 |
CAN adapters elements |
39 | Agricultural Machinery Flags | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Agricultural machinery flags | FMB640 FMC640 FMM640 |
CAN adapters elements |
40 | Harvesting Time | 4 | Unsigned | 0 | 16777215 | - | min | Harvesting Time, minutes | FMB640 FMC640 FMM640 |
CAN adapters elements |
41 | Area of Harvest | 4 | Unsigned | 0 | 4294967295 | - | m2 | Area of Harvest, m^2 | FMB640 FMC640 FMM640 |
CAN adapters elements |
42 | Mowing Efficiency | 4 | Unsigned | 0 | 4294967295 | - | m2/h | Mowing efficiency, (m^2)/h | FMB640 FMC640 FMM640 |
CAN adapters elements |
43 | Grain Mown Volume | 4 | Unsigned | 0 | 4294967295 | - | kg | Mown Volume, kg | FMB640 FMC640 FMM640 |
CAN adapters elements |
44 | Grain Moisture | 2 | Unsigned | 0 | 65535 | 0,1 | % | Grain Moisture in proc, % | FMB640 FMC640 FMM640 |
CAN adapters elements |
45 | Harvesting Drum RPM | 2 | Unsigned | 0 | 65535 | - | rpm | Harvesting Drum RPM, RPM | FMB640 FMC640 FMM640 |
CAN adapters elements |
46 | Gap Under Harvesting Drum | 1 | Unsigned | 0 | 255 | - | mm | Gap Under Harvesting Drum, mm | FMB640 FMC640 FMM640 |
CAN adapters elements |
47 | Security State Flags | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Security State Flag | FMB640 FMC640 FMM640 |
CAN adapters elements |
141 | Battery Temperature | 2 | Signed | -600 | 1270 | 0,1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
CAN adapters elements |
142 | Battery Level Percent | 1 | Unsigned | 0 | 255 | 0,1 | % | Value in percentages, % | FMB640 FMC640 FMM640 |
CAN adapters elements |
176 | DTC Errors | 1 | Unsigned | 0 | 255 | - | - | DTC Errors | FMB640 FMC640 FMM640 |
CAN adapters elements |
177 | DTC Codes | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
CAN adapters elements | |
226 | CNG Status | 1 | Unsigned | 0 | 1 | - | - |
0 - Engine not on CNG; |
FMB640 FMC640 FMM640 |
CAN adapters elements |
227 | CNG Used | 4 | Unsigned | 0 | 4294967295 | - | kg | CNG Used | FMB640 FMC640 FMM640 |
CAN adapters elements |
228 | CNG Level | 2 | Unsigned | 0 | 65535 | - | % | CNG Level | FMB640 FMC640 FMM640 |
CAN adapters elements |
Eventual I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
155 | Geofence zone 01 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
156 | Geofence zone 02 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
157 | Geofence zone 03 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
158 | Geofence zone 04 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
159 | Geofence zone 05 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
160 | Geofence zone 06 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
161 | Geofence zone 07 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
162 | Geofence zone 08 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
163 | Geofence zone 09 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
164 | Geofence zone 10 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
165 | Geofence zone 11 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
166 | Geofence zone 12 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
167 | Geofence zone 13 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
168 | Geofence zone 14 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
169 | Geofence zone 15 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
170 | Geofence zone 16 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
171 | Geofence zone 17 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
172 | Geofence zone 18 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
173 | Geofence zone 19 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
174 | Geofence zone 20 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
327 | Geofence zone 21 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
328 | Geofence zone 22 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
329 | Geofence zone 23 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
330 | Geofence zone 24 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
331 | Geofence zone 25 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
332 | Geofence zone 26 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
333 | Geofence zone 27 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
334 | Geofence zone 28 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
335 | Geofence zone 29 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
336 | Geofence zone 30 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
337 | Geofence zone 31 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
338 | Geofence zone 32 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
339 | Geofence zone 33 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
340 | Geofence zone 34 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
341 | Geofence zone 35 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
342 | Geofence zone 36 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
343 | Geofence zone 37 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
344 | Geofence zone 38 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
345 | Geofence zone 39 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
346 | Geofence zone 40 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
347 | Geofence zone 41 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
348 | Geofence zone 42 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
349 | Geofence zone 43 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
350 | Geofence zone 44 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
351 | Geofence zone 45 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
352 | Geofence zone 46 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
353 | Geofence zone 47 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
354 | Geofence zone 48 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
355 | Geofence zone 49 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
356 | Geofence zone 50 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
550 | Geofence zone 51 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
551 | Geofence zone 52 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
552 | Geofence zone 53 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
553 | Geofence zone 54 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
554 | Geofence zone 55 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
555 | Geofence zone 56 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
556 | Geofence zone 57 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
557 | Geofence zone 58 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
558 | Geofence zone 59 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
559 | Geofence zone 60 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
560 | Geofence zone 61 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
561 | Geofence zone 62 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
562 | Geofence zone 63 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
563 | Geofence zone 64 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
564 | Geofence zone 65 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
565 | Geofence zone 66 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
566 | Geofence zone 67 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
567 | Geofence zone 68 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
568 | Geofence zone 69 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
569 | Geofence zone 70 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
570 | Geofence zone 71 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
571 | Geofence zone 72 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
572 | Geofence zone 73 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
573 | Geofence zone 74 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
574 | Geofence zone 75 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
575 | Geofence zone 76 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
576 | Geofence zone 77 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
577 | Geofence zone 78 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
578 | Geofence zone 79 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
579 | Geofence zone 80 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
580 | Geofence zone 81 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
581 | Geofence zone 82 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
582 | Geofence zone 83 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
583 | Geofence zone 84 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
584 | Geofence zone 85 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
585 | Geofence zone 86 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
586 | Geofence zone 87 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
587 | Geofence zone 88 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
588 | Geofence zone 89 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
589 | Geofence zone 90 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
590 | Geofence zone 91 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
591 | Geofence zone 92 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
592 | Geofence zone 93 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
593 | Geofence zone 94 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
594 | Geofence zone 95 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone
|
FMB640 FMC640 FMM640 |
Eventual I/O elements |
595 | Geofence zone 96 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
596 | Geofence zone 97 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
597 | Geofence zone 98 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone
|
FMB640 FMC640 FMM640 |
Eventual I/O elements |
598 | Geofence zone 99 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
599 | Geofence zone 100 | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
175 | Auto Geofence | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
250 | Trip | 1 | Unsigned | 0 | 1 | - | - |
1 – trip start; |
FMB640 FMC640 FMM640 |
Permanent I/O elements |
255 | Over Speeding | 1 | Unsigned | 0 | 255 | - | km/h | At over speeding start km/h, at over speeding end km/h | FMB640 FMC640 FMM640 |
Eventual I/O elements |
243 | Idling | 1 | Unsigned | 0 | 1 | - | - |
0 – moving, |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
253 | Green Driving Type | 1 | Unsigned | 1 | 3 | - | - |
1 – harsh acceleration, |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
246 | Towing | 1 | Unsigned | 0 | 1 | - | - |
0 – steady, |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
248 | Geofence Zone Over Speeding | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Eventual I/O elements | |
247 | Crash Detection | 1 | Unsigned | 0 | 5 | - | - |
1 – Crash detected |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
251 | Immobilizer | 1 | Unsigned | 0 | 3 | - | - |
0 – iButton not connected |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
254 | Green Driving Value | 1 | Unsigned | 0 | 255 | acc and braking: 0.01 | G or rad | Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g), if harsh cornering – degrees (value in radians) | FMB640 FMC640 FMM640 |
Eventual I/O elements |
249 | Jamming | 1 | Unsigned | 0 | 1 | - | - |
1 – jamming start |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
252 | Authorized Driving | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Eventual I/O elements | |
242 | Data Limit Hit | 1 | Unsigned | 0 | 1 | - | - |
0 - Data limit hit in home; |
FMB640 FMC640 FMM640 |
Eventual I/O elements |
362 | Trace Order | 2 | Unsigned | 0 | 65535 | - | - | FMB640 FMC640 FMM640 |
Eventual I/O elements | |
358 | Custom Scenario 1 | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Eventual I/O elements | |
359 | Custom Scenario 2 | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Eventual I/O elements | |
360 | Custom Scenario 3 | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Eventual I/O elements | |
361 | Custom Scenario 4 | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Eventual I/O elements |
Manual CAN elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
145 | Manual CAN 00 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
146 | Manual CAN 01 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
147 | Manual CAN 02 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
148 | Manual CAN 03 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
149 | Manual CAN 04 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
150 | Manual CAN 05 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
151 | Manual CAN 06 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
152 | Manual CAN 07 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
153 | Manual CAN 08 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
154 | Manual CAN 09 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
380 | Manual CAN 10 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
381 | Manual CAN 11 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
382 | Manual CAN 12 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
383 | Manual CAN 13 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
384 | Manual CAN 14 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
385 | Manual CAN 15 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
386 | Manual CAN 16 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
387 | Manual CAN 17 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
388 | Manual CAN 18 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
389 | Manual CAN 19 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10298 | Manual CAN 20 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10299 | Manual CAN 21 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10300 | Manual CAN 22 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10301 | Manual CAN 23 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10302 | Manual CAN 24 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10303 | Manual CAN 25 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10304 | Manual CAN 26 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10305 | Manual CAN 27 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10306 | Manual CAN 28 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10307 | Manual CAN 29 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10308 | Manual CAN 30 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10309 | Manual CAN 31 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10310 | Manual CAN 32 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10311 | Manual CAN 33 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10312 | Manual CAN 34 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10313 | Manual CAN 35 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10314 | Manual CAN 36 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10315 | Manual CAN 37 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10316 | Manual CAN 38 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10317 | Manual CAN 39 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10318 | Manual CAN 40 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10319 | Manual CAN 41 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10320 | Manual CAN 42 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10321 | Manual CAN 43 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10322 | Manual CAN 44 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10323 | Manual CAN 45 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10324 | Manual CAN 46 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10325 | Manual CAN 47 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10326 | Manual CAN 48 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10327 | Manual CAN 49 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10328 | Manual CAN 50 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10329 | Manual CAN 51 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10330 | Manual CAN 52 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10331 | Manual CAN 53 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10332 | Manual CAN 54 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10333 | Manual CAN 55 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10334 | Manual CAN 56 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10335 | Manual CAN 57 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10336 | Manual CAN 58 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10337 | Manual CAN 59 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10338 | Manual CAN 60 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10339 | Manual CAN 61 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10340 | Manual CAN 62 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10341 | Manual CAN 63 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10342 | Manual CAN 64 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10343 | Manual CAN 65 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10344 | Manual CAN 66 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10345 | Manual CAN 67 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10346 | Manual CAN 68 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements | |
10347 | Manual CAN 69 | 1-8 | Unsigned | 0 | 0xffffffffffffffff | - | - | FMB640 FMC640 FMM640 |
Manual CAN elements |
Tachograph data elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
183 | Drive Recognize | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
184 | Driver 1 Working State | 1 | Unsigned | 0 | 5 | - | - |
0 - Rest; |
FMB640 FMC640 FMM640 |
Tachograph data elements |
185 | Driver 2 Working State | 1 | Unsigned | 0 | 5 | - | - |
0 - Rest; |
FMB640 FMC640 FMM640 |
Tachograph data elements |
186 | Tachograph Over Speed | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
187 | Driver 1 Card Presence | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
188 | Driver 2 Card Presence | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
189 | Driver 1 Time Related States | 1 | Unsigned | 0 | 15 | - | - |
0 – normal; |
FMB640 FMC640 FMM640 |
Tachograph data elements |
190 | Driver 2 Time Related States | 1 | Unsigned | 0 | 15 | - | - |
0 – normal; |
FMB640 FMC640 FMM640 |
Tachograph data elements |
191 | Vehicle Speed | 2 | Unsigned | 0 | 65535 | - | km/h | FMB640 FMC640 FMM640 |
Tachograph data elements | |
192 | Odometer | 4 | Unsigned | 0 | 4294967295 | - | m | Total vehicle distance | FMB640 FMC640 FMM640 |
Tachograph data elements |
193 | Trip Distance | 4 | Unsigned | 0 | 4294967295 | - | m | Current vehicle distance | FMB640 FMC640 FMM640 |
Tachograph data elements |
194 | Timestamp | 4 | Unsigned | 0 | 4294967295 | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
231 | Vehicle Registration Number Part1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | ASCII bytes | FMB640 FMC640 FMM640 |
Tachograph data elements |
232 | Vehicle Registration Number Part2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | ASCII bytes | FMB640 FMC640 FMM640 |
Tachograph data elements |
233 | Vehicle Identification Number Part1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | ASCII bytes | FMB640 FMC640 FMM640 |
Tachograph data elements |
234 | Vehicle Identification Number Part2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | ASCII bytes | FMB640 FMC640 FMM640 |
Tachograph data elements |
235 | Vehicle Identification Number Part3 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | ASCII bytes | FMB640 FMC640 FMM640 |
Tachograph data elements |
222 | Card 1 Issuing Member State | 1 | Unsigned | 0 | 255 | - | - | NationNumeric as described in EEC 3821_85 | FMB640 FMC640 FMM640 |
Tachograph data elements |
223 | Card 2 Issuing Member State | 1 | Unsigned | 0 | 255 | - | - | NationNumeric as described in EEC 3821_85 | FMB640 FMC640 FMM640 |
Tachograph data elements |
195 | Driver 1 ID MSB | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | How to read Driver ID | FMB640 FMC640 FMM640 |
Tachograph data elements |
196 | Driver 1 ID LSB | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | How to read Driver ID | FMB640 FMC640 FMM640 |
Tachograph data elements |
197 | Driver 2 ID MSB | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | How to read Driver ID | FMB640 FMC640 FMM640 |
Tachograph data elements |
198 | Driver 2 ID LSB | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | How to read Driver ID | FMB640 FMC640 FMM640 |
Tachograph data elements |
56 | Driver 1 Continuous Driving Time | 2 | Unsigned | 0 | 0xffff | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
57 | Driver 2 Continuous Driving Time | 2 | Unsigned | 0 | 0xffff | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
58 | Driver 1 Cumulative Break Time | 2 | Unsigned | 0 | 0xffff | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
59 | Driver 2 Cumulative Break Time | 2 | Unsigned | 0 | 0xffff | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
60 | Driver 1 Selected Activity Duration | 2 | Unsigned | 0 | 0xffff | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
61 | Driver 2 Selected Activity Duration | 2 | Unsigned | 0 | 0xffff | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
69 | Driver 1 Cumulative Driving Time | 2 | Unsigned | 0 | 0xffff | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
77 | Driver 2 Cumulative Driving Time | 2 | Unsigned | 0 | 0xffff | - | - | FMB640 FMC640 FMM640 |
Tachograph data elements | |
48 | Tacho Data Source | 1 | Unsigned | 0 | 4 | - | - |
0 - Unknown (data not available); |
FMB640 FMC640 FMM640 |
Tachograph data elements |
Mobileye elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
288 | ME Sound Type | 1 | Unsigned | 0 | 7 | - | - |
0 - Silent; |
FMB640 FMC640 FMM640 |
Mobileye elements |
289 | ME Pedestrians in Danger Zone | 1 | Unsigned | 0 | 1 | - | - |
0 - Pedestrian not in danger zone; |
FMB640 FMC640 FMM640 |
Mobileye elements |
290 | ME Pedestrians in Forward Collision Warning | 1 | Unsigned | 0 | 1 | - | - |
0 - No forward collision warning; |
FMB640 FMC640 FMM640 |
Mobileye elements |
291 | ME Time Indicator | 1 | Unsigned | 0 | 2 | - | - |
0 - Day is indicated; |
FMB640 FMC640 FMM640 |
Mobileye elements |
292 | ME Error Valid | 1 | Unsigned | 0 | 1 | - | - |
0 - Error; |
FMB640 FMC640 FMM640 |
Mobileye elements |
293 | ME Error Code | 1 | Unsigned | 0 | 127 | - | - | Error code | FMB640 FMC640 FMM640 |
Mobileye elements |
294 | ME Zero Speed | 1 | Unsigned | 0 | 1 | - | - |
0 - Host vehicle is moving; |
FMB640 FMC640 FMM640 |
Mobileye elements |
295 | ME Headway Valid | 1 | Unsigned | 0 | 1 | - | - |
0 - Headway Valid is off; |
FMB640 FMC640 FMM640 |
Mobileye elements |
296 | ME Headway Measurement | 1 | Unsigned | 0 | 9,9 | 0,1 | - |
Seconds |
FMB640 FMC640 FMM640 |
Mobileye elements |
297 | ME LDW Off | 1 | Unsigned | 0 | 1 | - | - |
0 - LDW are enabled; |
FMB640 FMC640 FMM640 |
Mobileye elements |
298 | ME Left LDW On | 1 | Unsigned | 0 | 1 | - | - |
0 - Left LDW are enabled; |
FMB640 FMC640 FMM640 |
Mobileye elements |
299 | ME Right LDW On | 1 | Unsigned | 0 | 1 | - | - |
0 - Right LDW are enabled; |
FMB640 FMC640 FMM640 |
Mobileye elements |
300 | ME Maintenance | 1 | Unsigned | 0 | 1 | - | - |
0 - Internal error is not detected; |
FMB640 FMC640 FMM640 |
Mobileye elements |
301 | ME Fail Safe | 1 | Unsigned | 0 | 1 | - | - |
0 - Fail Safe indicator is off; |
FMB640 FMC640 FMM640 |
Mobileye elements |
302 | ME FCW On | 1 | Unsigned | 0 | 1 | - | - |
0 - FCW are disabled; |
FMB640 FMC640 FMM640 |
Mobileye elements |
303 | ME TSR Enabled | 1 | Unsigned | 0 | 1 | - | - |
0 - TSR feature is disabled; 1 - TSR feature is enabled. |
FMB640 FMC640 FMM640 |
Mobileye elements |
304 | ME Headway Warning Repeat Enabled | 1 | Unsigned | 0 | 1 | - | - |
0 - Headway Warning Repeat is disabled; |
FMB640 FMC640 FMM640 |
Mobileye elements |
305 | ME Headway Warning Level | 1 | Unsigned | 0 | 2 | - | - |
0 - No CIPV is present; |
FMB640 FMC640 FMM640 |
Mobileye elements |
306 | ME TSR Warning Level | 1 | Unsigned | 0 | 7 | - | - |
0 - Speed <= Road Speed;
1 - Speed > Road Speed + [0-5 km/h]; |
FMB640 FMC640 FMM640 |
Mobileye elements |
307 | ME Tamper Alert | 1 | Unsigned | 0 | 1 | - | - |
0 - No tamper alert; |
FMB640 FMC640 FMM640 |
Mobileye elements |
308 | ME High Beam | 1 | Unsigned | 0 | 1 | - | - |
0 - Off; |
FMB640 FMC640 FMM640 |
Mobileye elements |
309 | ME Low Beam | 1 | Unsigned | 0 | 1 | - | - |
0 - Off; |
FMB640 FMC640 FMM640 |
Mobileye elements |
310 | ME Wipers | 1 | Unsigned | 0 | 1 | - | - |
0 - Off; |
FMB640 FMC640 FMM640 |
Mobileye elements |
311 | ME Right Signal | 1 | Unsigned | 0 | 1 | - | - |
0 - Off; |
FMB640 FMC640 FMM640 |
Mobileye elements |
312 | ME Left Signal | 1 | Unsigned | 0 | 1 | - | - |
0 - Off; |
FMB640 FMC640 FMM640 |
Mobileye elements |
313 | ME Brake Signal | 1 | Unsigned | 0 | 1 | - | - |
0 - Off; |
FMB640 FMC640 FMM640 |
Mobileye elements |
314 | ME Wipers Available | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Mobileye elements | |
315 | ME Low Beam Available | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Mobileye elements | |
316 | ME High Beam Available | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Mobileye elements | |
317 | ME Speed Available | 1 | Unsigned | 0 | 1 | - | - | FMB640 FMC640 FMM640 |
Mobileye elements | |
318 | ME Speed | 1 | Unsigned | 0 | 255 | - | km/h | FMB640 FMC640 FMM640 |
Mobileye elements | |
319 | ME TSR 1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Mobileye sign recognition data | FMB640 FMC640 FMM640 |
Mobileye elements |
320 | ME TSR 2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Mobileye sign recognition data | FMB640 FMC640 FMM640 |
Mobileye elements |
321 | ME TSR 3 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Mobileye sign recognition data | FMB640 FMC640 FMM640 |
Mobileye elements |
322 | ME TSR 4 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Mobileye sign recognition data | FMB640 FMC640 FMM640 |
Mobileye elements |
323 | ME TSR 5 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Mobileye sign recognition data | FMB640 FMC640 FMM640 |
Mobileye elements |
324 | ME TSR 6 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Mobileye sign recognition data | FMB640 FMC640 FMM640 |
Mobileye elements |
325 | ME TSR 7 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Mobileye sign recognition data | FMB640 FMC640 FMM640 |
Mobileye elements |
326 | ME TSR VO | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Mobileye vision only sign type data | FMB640 FMC640 FMM640 |
Mobileye elements |
ContiPressureCheck TPMS
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
10189 | Total Tires | 1 | Unsiged | 0 | 0xFF | - | TPMS Total Tires | FMB640 FMC640 FMM640 |
TPMS | |
10190 | Total Axles | 1 | Unsiged | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10191 | Graphical Position | 8 | Unsiged | 0 | 0xFFFFFFFFFFFFFFFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10192 | Tire 1 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10193 | Tire 2 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10194 | Tire 3 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10195 | Tire 4 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10196 | Tire 5 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10197 | Tire 6 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10198 | Tire 7 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10199 | Tire 8 pressure | 1 | HEX | 0 | 0xFF | - | kPan | FMB640 FMC640 FMM640 |
TPMS | |
10200 | Tire 9 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10201 | Tire 10 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10202 | Tire 11 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10203 | Tire 12 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10204 | Tire 13 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10205 | Tire 14 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10206 | Tire 15 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10207 | Tire 16 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10208 | Tire 17 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10209 | Tire 18 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10210 | Tire 19 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10211 | Tire 20 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10212 | Tire 21 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10213 | Tire 22 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10214 | Tire 23 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10215 | Tire 24 pressure | 1 | HEX | 0 | 0xFF | - | kPa | FMB640 FMC640 FMM640 |
TPMS | |
10360 | Tire 1 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10361 | Tire 1 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10362 | Tire 2 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10363 | Tire 2 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10364 | Tire 3 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10365 | Tire 3 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10366 | Tire 4 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10367 | Tire 4 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10368 | Tire 5 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10369 | Tire 5 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10370 | Tire 6 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10371 | Tire 6 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10372 | Tire 7 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10373 | Tire 7 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10374 | Tire 8 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10375 | Tire 8 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10376 | Tire 9 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10377 | Tire 9 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10378 | Tire 10 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10379 | Tire 10 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10380 | Tire 11 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10381 | Tire 11 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10382 | Tire 12 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10383 | Tire 12 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10384 | Tire 13 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10385 | Tire 13 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10386 | Tire 14 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10387 | Tire 14 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10388 | Tire 15 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10389 | Tire 15 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10390 | Tire 16 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10391 | Tire 16 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10392 | Tire 17 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10393 | Tire 17 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10394 | Tire 18 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10395 | Tire 18 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10396 | Tire 19 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10397 | Tire 19 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10398 | Tire 20 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10399 | Tire 20 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10400 | Tire 21 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
104001 | Tire 21 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10402 | Tire 22 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10403 | Tire 22 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10404 | Tire 23 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10405 | Tire 23 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS | ||
10406 | Tire 24 Temperature | 1 | HEX | 0 | 0xFF | - | °C | FMB640 FMC640 FMM640 |
TPMS | |
10407 | Tire 24 Warning | 1 | HEX | 0 | 0xFF | - | FMB640 FMC640 FMM640 |
TPMS |
Freezer IO
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
10040 | Fuel Level | 1 | Unsigned | 0 | 127.5 | 0.5 | % | FMB640 FMC640 FMM640 |
Freezer IO | |
10041 | Battery Voltage | 2 | Unsigned | 0 | 3276.75 | 0.1 | V | FMB640 FMC640 FMM640 |
Freezer IO | |
10042 | Total Electric Minutes | 4 | Unsigned | 0 | 214748364.8 | 1 | min | FMB640 FMC640 FMM640 |
Freezer IO | |
10043 | Total Vehicle Minutes | 4 | Unsigned | 0 | 214748364.8 | 1 | min | FMB640 FMC640 FMM640 |
Freezer IO | |
10044 | Total Engine Minutes | 4 | Unsigned | 0 | 214748364.8 | 1 | min | FMB640 FMC640 FMM640 |
Freezer IO | |
10045 | Zone 1 Alarm Type | 1 | Unsigned | 0 | 15 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10046 | Zone 1 Alarm Code | 1 | Unsigned | 0 | 255 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10047 | Zone 1 Return Air Temperature 1 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10048 | Zone 1 Supply Air Temperature 1 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10049 | Zone 1 Temperature Setpoint | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10050 | Zone 1 Evaporator Coil Temperature | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10051 | Zone 1 Return Air Temperature 2 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10052 | Zone 1 Supply Air Temperature 2 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10053 | Zone 1 Operating Mode | 1 | Unsigned | 0 | 7 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10054 | Zone 2 Alarm Type | 1 | Unsigned | 0 | 15 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10055 | Zone 2 Alarm Code | 1 | Unsigned | 0 | 255 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10056 | Zone 2 Return Air Temperature 1 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10057 | Zone 2 Supply Air Temperature 1 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10058 | Zone 2 Temperature Setpoint | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10059 | Zone 2 Evaporator Coil Temperature | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10060 | Zone 2 Return Air Temperature 2 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10061 | Zone 2 Supply Air Temperature 2 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10062 | Zone 2 Operating Mode | 1 | Unsigned | 0 | 7 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10063 | Zone 3 Alarm Type | 1 | Unsigned | 0 | 15 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10064 | Zone 3 Alarm Code | 1 | Unsigned | 0 | 255 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10065 | Zone 3 Return Air Temperature 1 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10066 | Zone 3 Supply Air Temperature 1 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10067 | Zone 3 Temperature Setpoint | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10068 | Zone 3 Evaporator Coil Temperature | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10069 | Zone 3 Return Air Temperature 2 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10070 | Zone 3 Supply Air Temperature 2 | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10071 | Zone 3 Operating Mode | 1 | Unsigned | 0 | 7 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10350 | Ambient Air Temperature | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10351 | Coolant Temperature | 2 | Signed | -1838.2 | 1802.6 | 0.1 | °C | Degrees, °C | FMB640 FMC640 FMM640 |
Freezer IO |
10352 | Error Count | 1 | Unsigned | 0 | 255 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10353 | RPM | 2 | Unsigned | 0 | 200000 | - | rpm | FMB640 FMC640 FMM640 |
Freezer IO | |
10354 | RPM | 1 | Unsigned | 0 | 255 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10355 | Door status | 1 | Unsigned | 0 | 255 | - | - | FMB640 FMC640 FMM640 |
Freezer IO | |
10356 | Instalation Serial | 8 | Unsigned | 0 | 0xffffffffffffffff | - | String | FMB640 FMC640 FMM640 |
Freezer IO | |
10357 | Trailer Serial | 8 | Unsigned | 0 | 0xffffffffffffffff | - | String | FMB640 FMC640 FMM640 |
Freezer IO |