*Supported by <span class="mw-collapsible mw-collapsed"> [https://wiki.teltonika-gps.com/view/FMB110 FMB110], [https://wiki.teltonika-gps.com/view/FMB120 FMB120], [https://wiki.teltonika-gps.com/view/FMB122 FMB122], [https://wiki.teltonika-gps.com/view/FMB125 FMB125], [https://wiki.teltonika-gps.com/view/FMU125 FMU125], [https://wiki.teltonika-gps.com/view/FMM125 FMM125], [https://wiki.teltonika-gps.com/view/FMC125 FMC125], [https://wiki.teltonika-gps.com/view/FMB130 FMB130], [https://wiki.teltonika-gps.com/view/FMU130 FMU130], [https://wiki.teltonika-gps.com/view/FMC130 FMC130], [https://wiki.teltonika-gps.com/view/FMM130 FMM130], [https://wiki.teltonika-gps.com/view/FMB140 FMB140], [https://wiki.teltonika-gps.com/view/FMB202 FMB202], [https://wiki.teltonika-gps.com/view/FMB204 FMB204], [https://wiki.teltonika-gps.com/view/FMB640 FMB640], [https://wiki.teltonika-gps.com/view/FMC640 FMC640], [https://wiki.teltonika-gps.com/view/FMM640 FMM640] </span>
 
*Stainless Steel Tube
 
*Stainless Steel Tube
 
*1-Wire Interface
 
*1-Wire Interface

Revision as of 11:38, 13 September 2021

Main Page > Accessories > 1-Wire Temperature Sensors

Introduction to the product

Description:

One of the implemented features for fleet management devices is a 1-Wire data protocol, which enables the connection of temperature sensors. It is a perfect accessory for temperature monitoring.

1-Wire temperature sensors is a great addition for your fleet management trackers in the following use cases:

  • Thermostatic controls – maintain temperature near a desired set point.
  • Thermally sensitive system – receive alerts when temperature enters or leaves pre-defined value.
  • Consumer products – be assured that the goods which you are delivering will maintain high quality.





Product Specification

Installation

To connect the 1-wire temperature sensor you have to make sure to connect 3 PINs of the sensor to the PINs of your device correctly.

Up to 4 sensors can be connected to our devices simultaneously.

Io 1wire temp diagram.png

PIN NUMBER PIN NAME

DESCRIPTION

1 1-wire Data Outputs temperature data via 1-Wire interface
2 1-wire Power Power supply for the sensor (can be left disconnected in parasitic connection)
3 GND (-) Ground.


Device configuration

The device reads the sensor data automatically after the sensors are connected, however, the I/O elements are disabled by default to save data. To receive data to the server, make sure that the appropriate I/O elements(Dallas Temperature # / Dallas Temperature ID #) are enabled.Io 1wire temp.png

The first ID is the sensor that is connected first, which can be changed from the software side without disconnecting the sensors. It can be done by navigating to the 1-Wire section and assigning the IDs of the sensors in your desired order.

Io 1wire temp2.png