Difference between revisions of "How to capture CAN adapter log from FMX1YX"
(Updated with latest information about filters) |
BaronenasT (talk | contribs) |
||
Line 12: | Line 12: | ||
# If FW version is <b>03.27.10</b> or higher <code>cpureset</code> command is not necessary to enable the filters. On lower versions <code>cpureset</code> is mandatory. | # If FW version is <b>03.27.10</b> or higher <code>cpureset</code> command is not necessary to enable the filters. On lower versions <code>cpureset</code> is mandatory. | ||
#*<p>If you have set SMS login and password: <code>login pass cpureset</code></p> | #*<p>If you have set SMS login and password: <code>login pass cpureset</code></p> | ||
− | #*<p>If SMS login and password are not set leave two spaces before command:<code><span style="color:#f8f9fa">aa</span>cpureset</code> | + | #*<p>If SMS login and password are not set leave two spaces before command:<code><span style="color:#f8f9fa">aa</span>cpureset</code></p> |
#After the SMS response message CAN adapter log capturing has been started. | #After the SMS response message CAN adapter log capturing has been started. | ||
#Wait at least '''5 minutes''' to get enough CAN bus data and '''turn off''' vehicle engine. | #Wait at least '''5 minutes''' to get enough CAN bus data and '''turn off''' vehicle engine. |
Revision as of 08:05, 13 October 2023
Main Page > Frequently Asked Questions - FAQ > How to capture CAN adapter log from FMX1YXSolution applies for these devices
FMB110 FMB120 FMB122 FMB125 FMB140 FMC125 FMC130 FMM125 FMM130 FMC125 FMU126 FMU130
Here are steps how to capture LV-CAN200, ALL-CAN300, CAN-CONTROL log from FMB1YX series devices.
This functionality is available after 03.08.00 firmware version.
- Make sure that the CAN adapter is connected properly to the vehicle and to the FMB1YX series device.
- Start vehicle engine.
- Send following SMS commands to FMX1YX device:
- If you have set SMS login and password:
login pass log2sdfilterset 0;2;3;4;1
- If SMS login and password are not set leave two spaces before command:
aalog2sdfilterset 0;2;3;4;1
If command
log2sdfilterset
was sent correctly you should receive SMS Response:Enabled Trace Filters:5
then you can restart the device
- If you have set SMS login and password:
- If FW version is 03.27.10 or higher
cpureset
command is not necessary to enable the filters. On lower versionscpureset
is mandatory.If you have set SMS login and password:
login pass cpureset
If SMS login and password are not set leave two spaces before command:
aacpureset
- After the SMS response message CAN adapter log capturing has been started.
- Wait at least 5 minutes to get enough CAN bus data and turn off vehicle engine.
- Download captured log (dump) files.
Using Teltonika Configurator
Please check Status info→Maintenance→Log/Dump and download dump YYYY_MM_DD_HH_MM_SS_FMB1YX_IMEI_Dump.zip
.
Using FOTA WEB
Enter FOTA WEB → Press on Devices tab → Select your device and press → Task type → Receive internal log (5) (5 files. Each log size up to 1 MB)→.
To start download process at once send following SMS command:
- If you have set SMS login and password:
login pass web_connect
- If SMS login and password are not set leave two spaces before command:
aaweb_connect
If command was sent correctly you should receive SMS Response:
web_connect resp:OK
To find downloaded log press on Tasks tab→Find your device by IMEI and Task type Received internal log→Download
IMEI_logs_TIMESTAMP.zip
as showed below:
- If you have set SMS login and password:
- After you have downloaded log files send following SMS command to FMX1YX device:
- If you have set SMS login and password:
login pass log2sdfilterset 0
- If SMS login and password are not set leave two spaces before command:
aalog2sdfilterset 0
If command was sent correctly you should receive SMS Response:
Enabled Trace Filters:1
- If you have set SMS login and password:
- These log (dump) files can be read only with special software. Provide these files to your Teltonika Telematics Sales manager or Teltonika Telematics Support team for further investigation.