Jump to content

Test-AC: Difference between revisions

From Teltonika Telematics Wiki
No edit summary
No edit summary
Line 1: Line 1:
https://wiki.teltonika-gps.com/view/Template:FTX_Features
===EYE Beacon===
=SECO Scenario=
{| class="wikitable"
[[File:FTX SECO.png|right|500px]]
|+
 
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter ID'''
'''Secure Engine Cut Off (SECO)''' is a functionality that safely disables a vehicle’s engine based on predefined speed or movement conditions. It is typically activated remotely and used for security, immobilization, or theft prevention purposes.
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter Type'''
 
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Default value'''
SECO enhances vehicle security by allowing the engine to be disabled under controlled conditions. It helps prevent theft by stopping unauthorized movement, supports fleet security through remote immobilization when suspicious activity occurs, and limits unauthorized usage by shutting down the engine when vehicles operate outside permitted times or areas.
! colspan="2" style="width: 150px; background: black; color: white;" |'''Value range'''
 
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Value'''
To safely slow down a vehicle after receiving the <code>secoon</code> command, the device waits for the vehicle speed to drop below the configured '''Speed pulse scenario (km/h)''' threshold. Once the speed remains below this threshold for the configured '''Speed check period''', the device starts pulsing the configured '''DOUT''' to toggle the relay connected to the fuel pump. This intermittently interrupts the fuel supply and gradually slows down the vehicle.
! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter name'''
 
|-
When the vehicle speed further decreases and reaches the configured '''Speed (km/h)''' threshold, the system activates the configured '''DOUT permanently''', fully interrupting the fuel supply and bringing the vehicle to a complete stop.
! style="width: 75px; background: black; color: white;" |Min
 
! style="width: 75px; background: black; color: white;" |Max
DOUT control remains active until the <code>secoff</code> command is received.
|-
 
! style="text-align: center; vertical-align: center;" |129
===<u>Prerequisites and Important Settings</u>===
| style="text-align: center; vertical-align: center;" |-
*The device must have at least one free DOUT that can be assigned to SECO functionality.
| style="text-align: center; vertical-align: center;" |60
*For SECO functionality to work, DOUT must be selected. SECO has DOUT control priority higher than immobilizer scenario.
| style="text-align: center; vertical-align: center;" |5
*'''IMOPORTANT:''' If the pulse parameter is disabled while pulsing is active, the DOUT will activate instantly.
| style="text-align: center; vertical-align: center;" |3600
*'''IMPORTANT:''' The SECO scenario must be controlled using SMS and GPRS commands, enabling remote activation and deactivation of the engine cut off functionality.
| style="text-align: center; vertical-align: center;" |-
 
| style="text-align: center; vertical-align: center;" |EYE Beacon Clear Timeout
 
|-
===<u>Basic Operation</u>===
! style="text-align: center; vertical-align: center;" |144
The SECO scenario supports the following engine cut off modes, each using different logic for controlling a digital output (DOUT) based on speed, movement, and data availability.
| style="text-align: center; vertical-align: center;" |-
 
| style="text-align: center; vertical-align: center;" |10
====Speed Pulse====
| style="text-align: center; vertical-align: center;" |5
The Speed pulse scenario (km/h) parameter defines the speed threshold at which pulsed DOUT control begins.
| style="text-align: center; vertical-align: center;" |3600
DOUT pulsing starts when:
| style="text-align: center; vertical-align: center;" |-
*Vehicle speed drops below Speed pulse scenario (km/h)
| style="text-align: center; vertical-align: center;" |Beacon Clear Timeout
*Speed remains below this threshold for the configured Speed check period
|-
 
! rowspan="3" style="text-align: center; vertical-align: center;" |149
Once these conditions are met, the device begins toggling the configured DOUT according to the DOUT ON duration and DOUT OFF duration settings.
| rowspan="3" style="text-align: center; vertical-align: center;" |-
 
| rowspan="3" style="text-align: center; vertical-align: center;" |0
If the vehicle speed increases above the configured Speed pulse scenario threshold, the Speed check period timer is reset.
| rowspan="3" style="text-align: center; vertical-align: center;" |0
 
| rowspan="3" style="text-align: center; vertical-align: center;" |2
====Safe Stop Threshold====
| style="text-align: center; vertical-align: center;" |0 - Disabled
The '''Speed (km/h)''' parameter defines the speed at which the system switches from pulsed control to '''permanent DOUT activation'''.
| rowspan="3" style="text-align: center; vertical-align: center;" |EYE Beacon Detection
 
|-
When the vehicle speed reaches or falls below this value, the configured '''DOUT''' is activated continuously, completely disabling the fuel pump and stopping the vehicle.
| style="text-align: center; vertical-align: center;" |1 - All
 
|-
====GNSS Available====
|style="text-align: center; vertical-align: center;" |2 - Configured
When a GNSS fix is available, vehicle speed is determined using GNSS data and the SECO process follows the normal flow:
|-
#Wait until speed drops below '''Speed pulse scenario (km/h)'''
! rowspan="3" style="text-align: center; vertical-align: center;" |2248
#Start pulsing DOUT after the '''Speed check period'''
| rowspan="3" style="text-align: center; vertical-align: center;" |-
#Activate '''DOUT permanently''' when speed reaches '''Speed (km/h)'''
| rowspan="3" style="text-align: center; vertical-align: center;" |0
 
| rowspan="3" style="text-align: center; vertical-align: center;" |0
====GNSS Unavailable====
| rowspan="3" style="text-align: center; vertical-align: center;" |2
If a ''''GNSS fix''' is not available, vehicle speed cannot be reliably determined. In this case, the system uses a safety fallback mechanism.
| style="text-align: center; vertical-align: center;" |0 - Disabled
 
| rowspan="3" style="text-align: center; vertical-align: center;" |Proximity Near Event
After receiving the secoon command, the device waits until:
|-
*No movement is detected
| style="text-align: center; vertical-align: center;" |1 - Periodic
*The configured Movement timeout is reached
|-
Once these conditions are met, the configured '''DOUT''' is activated.
|style="text-align: center; vertical-align: center;" |2 - On change
 
|-
This ensures that the fuel supply is not interrupted while the vehicle might still be moving at high speed.
! rowspan="3" style="text-align: center; vertical-align: center;" |2249
 
| rowspan="3" style="text-align: center; vertical-align: center;" |-
=== <u> Parameters list </u>===
| rowspan="3" style="text-align: center; vertical-align: center;" |0
<table class="nd-othertables_2" style="width:100%; border-collapse: collapse;">
| rowspan="3" style="text-align: center; vertical-align: center;" |0
<tr>
| rowspan="3" style="text-align: center; vertical-align: center;" |2
<th style="width:1%; vertical-align: middle; text-align: center;">PARAMETER NAME</th>
| style="text-align: center; vertical-align: center;" |0 - Disabled
<th style="width:1%; vertical-align: middle; text-align: center;">PARAMETER ID (RELATED AVL ID)</th>
| rowspan="3" style="text-align: center; vertical-align: center;" |Proximity Away Event
<th style="width:5%; vertical-align: middle; text-align: center;">DESCRIPTION</th>
|-
<th style="width:6%; vertical-align: middle; text-align: center;">VALUES</th>
| style="text-align: center; vertical-align: center;" |1 - Periodic
</tr>
|-
<tr>
|style="text-align: center; vertical-align: center;" |2 - On change
 
|-
<td style="vertical-align: middle; text-align: center;"> SECO DOUT status </td>
! rowspan="3" style="text-align: center; vertical-align: center;" |2251
<td style="vertical-align: middle; text-align: center;"> 396</td>
| rowspan="3" style="text-align: center; vertical-align: center;" |-
<td style="vertical-align: middle; text-align: center;"> SECO DOUT status. </td>
| rowspan="3" style="text-align: center; vertical-align: center;" |0
<td style="vertical-align: middle; text-align: left;">'''0''' = SECO DOUT is '''OFF''' <br> '''1''' = SECO DOUT is '''pulsing''' <br> '''2''' = SECO DOUT is '''ON''' </td>
| rowspan="3" style="text-align: center; vertical-align: center;" |0
 
| rowspan="3" style="text-align: center; vertical-align: center;" |2
</tr>
| style="text-align: center; vertical-align: center;" |0 - Disabled
<tr>
| rowspan="3" style="text-align: center; vertical-align: center;" |Proximity Lost Event
 
|-
<td style="vertical-align: middle; text-align: center;"> Priority </td>
| style="text-align: center; vertical-align: center;" |1 - Periodic
<td style="vertical-align: middle; text-align: center;"> 1039600 </td>
|-
<td style="vertical-align: middle; text-align: center;"> Priority of how events are being sent to a server. For example, events with low priority are added to the periodical record, and events with high priority are sent immediately after they occur. </td>
|style="text-align: center; vertical-align: center;" |2 - On change
<td style="vertical-align: middle; text-align: left;"> '''0''' = SECO  scenario is '''disabled''' <br> '''1''' = SECO scenario is '''low''' <br> '''2''' = SECO scenario is '''high''' <br>
|-
</td>
! style="text-align: center; vertical-align: center;" |2252
 
| style="text-align: center; vertical-align: center;" |-
</tr>
| style="text-align: center; vertical-align: center;" |5
<tr>
| style="text-align: center; vertical-align: center;" |0
 
| style="text-align: center; vertical-align: center;" |300
<td style="vertical-align: middle; text-align: center;"> Speed </td>
| style="text-align: center; vertical-align: center;" |-
<td style="vertical-align: middle; text-align: center;"> 12254 </td>
| style="text-align: center; vertical-align: center;" |RSSI averaging const
<td style="vertical-align: middle; text-align: center;"> Speed threshold at which the configured digital output (DOUT) will be activated. </td>
|-
<td style="vertical-align: middle; text-align: left;"> Minimum value = '''0'''<br> Maximum value = '''255''' <br> Default value = '''10''' </td>
! style="text-align: center; vertical-align: center;" |2253
 
| style="text-align: center; vertical-align: center;" |-
</tr>
| style="text-align: center; vertical-align: center;" |5
<tr>
| style="text-align: center; vertical-align: center;" |0
 
| style="text-align: center; vertical-align: center;" |300
<td style="vertical-align: middle; text-align: center;"> Speed pulse scenario </td>
| style="text-align: center; vertical-align: center;" |-
<td style="vertical-align: middle; text-align: center;"> 12259 </td>
| style="text-align: center; vertical-align: center;" |RSSI averaging const
<td style="vertical-align: middle; text-align: center;">
|-
Speed threshold at which the configured digital output (DOUT) will be toggled. </td>
! style="text-align: center; vertical-align: center;" |2254
<td style="vertical-align: middle; text-align: left;"> Minimum value = '''0'''<br> Maximum value = '''255''' <br>Default value = '''10''' </td>
| style="text-align: center; vertical-align: center;" |-
 
| style="text-align: center; vertical-align: center;" |-40
</tr>
| style="text-align: center; vertical-align: center;" |-100
<tr>
| style="text-align: center; vertical-align: center;" |-20
 
| style="text-align: center; vertical-align: center;" |-
<td style="vertical-align: middle; text-align: center;">
| style="text-align: center; vertical-align: center;" |Proximity RSSI near
Speed check period </td>
|-
<td style="vertical-align: middle; text-align: center;"> 12255 </td>
! style="text-align: center; vertical-align: center;" |2256
<td style="vertical-align: middle; text-align: center;"> Time span during which speed must be lower than configured for output to activate (GNSS on). </td>
| style="text-align: center; vertical-align: center;" |-
<td style="vertical-align: middle; text-align: left;">  Minimum value = '''0'''<br> Maximum value = '''65535''' <br>Default value = '''10''' </td>
| style="text-align: center; vertical-align: center;" |60
 
| style="text-align: center; vertical-align: center;" |0
</tr>
| style="text-align: center; vertical-align: center;" |2592000
<tr>
| style="text-align: center; vertical-align: center;" |0 - Disabled
 
| style="text-align: center; vertical-align: center;" |Record Period On Move
<td style="vertical-align: middle; text-align: center;">
|-
Movement timeout</td>
! style="text-align: center; vertical-align: center;" |2257
<td style="vertical-align: middle; text-align: center;"> 12256 </td>
| style="text-align: center; vertical-align: center;" |-
<td style="vertical-align: middle; text-align: center;"> Duration after which the DOUT will be activated if no movement is detected and GNSS is off. </td>
| style="text-align: center; vertical-align: center;" |60
<td style="vertical-align: middle; text-align: left;">  Minimum value = '''0'''<br> Maximum value = '''65535''' <br>Default value = '''30''' </td>
| style="text-align: center; vertical-align: center;" |0
 
| style="text-align: center; vertical-align: center;" |2592000
</tr>
| style="text-align: center; vertical-align: center;" |0 - Disabled
<tr>
| style="text-align: center; vertical-align: center;" |Record Period On Stop
 
|-
<td style="vertical-align: middle; text-align: center;">Eventual records</td>
! rowspan="2" style="text-align: center; vertical-align: center;" |2300
<td style="vertical-align: middle; text-align: center;"> 1039604</td>
| rowspan="2" style="text-align: center; vertical-align: center;" |-
<td style="vertical-align: middle; text-align: center;">Enables feature status sending only when the event happens (an eventual record). When disabled, feature status will be sent with both eventual and periodical records.</td>
| rowspan="2" style="text-align: center; vertical-align: center;" |0
<td style="vertical-align: middle; text-align: left;"> '''0''' = SECO status will be sent with both eventual and periodical records. <br> '''1''' = SECO status will be sent only when the event happens (an eventual record).</td>
| rowspan="2" style="text-align: center; vertical-align: center;" |0
 
| rowspan="2" style="text-align: center; vertical-align: center;" |1
</tr>
| style="text-align: center; vertical-align: center;" |0 - Proximity
<tr>
| rowspan="2" style="text-align: center; vertical-align: center;" |EYE Feature Mode
 
|-
<td style="vertical-align: middle; text-align: center;">Output control</td>
| style="text-align: center; vertical-align: center;" |1 - Lost&Found
<td style="vertical-align: middle; text-align: center;">12252</td>
|-
<td style="vertical-align: middle; text-align: center;">
! rowspan="2" style="text-align: center; vertical-align: center;" |2301
Digital output used for connection to fuel pump to gradually stop the vehicle. </td>
| rowspan="2" style="text-align: center; vertical-align: center;" |-
<td style="vertical-align: middle; text-align: left;"> '''0''' = DOUT control is disabled <br> '''1''' = DOUT1 is controlled <br> '''2''' = DOUT2 is controlled <br> '''3''' = DOUT3 is controlled <br> '''4''' = DOUT4 is controlled</td>
| rowspan="2" style="text-align: center; vertical-align: center;" |0
 
| rowspan="2" style="text-align: center; vertical-align: center;" |0
</tr>
| rowspan="2" style="text-align: center; vertical-align: center;" |1
<tr>
| style="text-align: center; vertical-align: center;" |0 - Disable
 
| rowspan="2" style="text-align: center; vertical-align: center;" |EYE Feature Mode
<td style="vertical-align: middle; text-align: center;">Output pulse</td>
|-
<td style="vertical-align: middle; text-align: center;">12253</td>
| style="text-align: center; vertical-align: center;" |1 - Enable
<td style="vertical-align: middle; text-align: center;">Pulse functionality adds additional output control which helps to slow down vehicle before fully disabling fuel pump.</td>
|-
<td style="vertical-align: middle; text-align: left;"> '''0''' = Disabled <br> '''1''' = Enabled </td>
! rowspan="2" style="text-align: center; vertical-align: center;" |2302
 
| rowspan="2" style="text-align: center; vertical-align: center;" |-
</tr>
| rowspan="2" style="text-align: center; vertical-align: center;" |0
<tr>
| rowspan="2" style="text-align: center; vertical-align: center;" |0
 
| rowspan="2" style="text-align: center; vertical-align: center;" |1
<td style="vertical-align: middle; text-align: center;">
| style="text-align: center; vertical-align: center;" |0 - Disable
DOUT on duration</td>
| rowspan="2" style="text-align: center; vertical-align: center;" |Found Beacon List
<td style="vertical-align: middle; text-align: center;">12257</td>
|-
<td style="vertical-align: middle; text-align: center;"> Duration for how long DOUT should be active.</td>
| style="text-align: center; vertical-align: center;" |1 - Enable
<td style="vertical-align: middle; text-align: left;"> Minimum value = '''10'''<br> Maximum value = '''5000''' <br>Default value = '''1000''' </td>
|-
 
! rowspan="2" style="text-align: center; vertical-align: center;" |2303
</tr>
| rowspan="2" style="text-align: center; vertical-align: center;" |-
<tr>
| rowspan="2" style="text-align: center; vertical-align: center;" |0
 
| rowspan="2" style="text-align: center; vertical-align: center;" |0
<td style="vertical-align: middle; text-align: center;">DOUT off duration</td>
| rowspan="2" style="text-align: center; vertical-align: center;" |1
<td style="vertical-align: middle; text-align: center;">12258</td>
| style="text-align: center; vertical-align: center;" |0 - Disable
<td style="vertical-align: middle; text-align: center;"> A value in milliseconds, for how long DOUT should be inactive. </td>
| rowspan="2" style="text-align: center; vertical-align: center;" |Lost Beacon List
<td style="vertical-align: middle; text-align: left;"> Minimum value = '''10'''<br> Maximum value = '''5000''' <br>Default value = '''1000''' </td>
|-
 
| style="text-align: center; vertical-align: center;" |1 - Enable
</tr>
|-
</table>
! rowspan="3" style="text-align: center; vertical-align: center;" |2304
 
| rowspan="3" style="text-align: center; vertical-align: center;" |-
<!---For Template:FTX SMS/GPRS Commands--->
| rowspan="3" style="text-align: center; vertical-align: center;" |1
{{#if: {{FTX Pin Support List|model={{{model}}}|pin=DOUT1}}{{FTX Pin Support List|model={{{model}}}|pin=DOUT2}}{{FTX Pin Support List|model={{{model}}}|pin=DOUT3}}
| rowspan="3" style="text-align: center; vertical-align: center;" |1
|
| rowspan="3" style="text-align: center; vertical-align: center;" |3
===SECO Commands===
| style="text-align: center; vertical-align: center;" |1 - ID
<table class="nd-othertables_2" style="width:100%; border-collapse: collapse;">
| rowspan="3" style="text-align: center; vertical-align: center;" |Identifier
<tr>
|-
<th style="width:20%; vertical-align: middle; text-align: left;">COMMAND</th>
| style="text-align: center; vertical-align: center;" |2 - MAC
<th style="width:45%; vertical-align: middle; text-align: left;">DESCRIPTION</th>
|-
<th style="width:35%; vertical-align: middle; text-align: left;">SYNTAX EXAMPLE</th>
| 3- ID and MAC
</tr>
|-
<tr>
! rowspan="3" style="text-align: center; vertical-align: center;" |2305
<td style="vertical-align: middle; text-align: left;">[[SMS/GPRS command - secooff|secooff]]</td>
| rowspan="3" style="text-align: center; vertical-align: center;" |-
<td style="vertical-align: middle; text-align: left;">Deactivate SECO scenario.</td>
| rowspan="3" style="text-align: center; vertical-align: center;" |0
<td style="vertical-align: middle; text-align: left;"><code>secooff</code></td>
| rowspan="3" style="text-align: center; vertical-align: center;" |3
</tr>
| rowspan="3" style="text-align: center; vertical-align: center;" |3
<tr>
| style="text-align: center; vertical-align: center;" |1 - Low Battery
<td style="vertical-align: middle; text-align: left;">[[SMS/GPRS command - secoon|secoon]]</td>
| rowspan="3" style="text-align: center; vertical-align: center;" |Battery Data
<td style="vertical-align: middle; text-align: left;">Activate SECO scenario.</td>
|-
<td style="vertical-align: middle; text-align: left;"><code>secoon</code></td>
| style="text-align: center; vertical-align: center;" |2 - Battery Voltage
</tr>
|-
</table>
| 3 - Low Battery and Battery Voltage
}}
|-
|}

Revision as of 09:19, 23 March 2026

EYE Beacon

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
129 - 60 5 3600 - EYE Beacon Clear Timeout
144 - 10 5 3600 - Beacon Clear Timeout
149 - 0 0 2 0 - Disabled EYE Beacon Detection
1 - All
2 - Configured
2248 - 0 0 2 0 - Disabled Proximity Near Event
1 - Periodic
2 - On change
2249 - 0 0 2 0 - Disabled Proximity Away Event
1 - Periodic
2 - On change
2251 - 0 0 2 0 - Disabled Proximity Lost Event
1 - Periodic
2 - On change
2252 - 5 0 300 - RSSI averaging const
2253 - 5 0 300 - RSSI averaging const
2254 - -40 -100 -20 - Proximity RSSI near
2256 - 60 0 2592000 0 - Disabled Record Period On Move
2257 - 60 0 2592000 0 - Disabled Record Period On Stop
2300 - 0 0 1 0 - Proximity EYE Feature Mode
1 - Lost&Found
2301 - 0 0 1 0 - Disable EYE Feature Mode
1 - Enable
2302 - 0 0 1 0 - Disable Found Beacon List
1 - Enable
2303 - 0 0 1 0 - Disable Lost Beacon List
1 - Enable
2304 - 1 1 3 1 - ID Identifier
2 - MAC
3- ID and MAC
2305 - 0 3 3 1 - Low Battery Battery Data
2 - Battery Voltage
3 - Low Battery and Battery Voltage