Permanent I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
239 Ignition 1 Unsigned 0 1 - -

0 – Ignition Off
1 – Ignition On

FMB640
FMC640
FMM640

Permanent I/O elements
240 Movement 1 Unsigned 0 1 - -

0 – Movement Off
1 – Movement On

FMB640
FMC640
FMM640

Permanent I/O elements
22 Data Mode 1 Unsigned 0 5 - -

0 – Home On Stop
1 – Home On Moving
2 – Roaming On Stop
3 – Roaming On Moving
4 – Unknown On Stop
5 – Unknown On Moving

FMB640
FMC640
FMM640

Permanent I/O elements
21 GSM Signal 1 Unsigned 0 5 - - Value in range 1-5 FMB640
FMC640
FMM640
Permanent I/O elements
200 Sleep Mode 1 Unsigned 0 1 - -

Normal mode
Deep Sleep

FMB640
FMC640
FMM640
Permanent I/O elements
71 GNSS Status 1 Unsigned 0 5 - -

0 - GNSS OFF
1 - GNSS ON, no GPS antena
2 - GNSS ON, without fix
3 - GNSS ON, with fix
4 - GNSS SLEEP
5 - GNSS Overcurrent/protect state

FMB640
FMC640
FMM640
Permanent I/O elements
181 GNSS PDOP 2 Unsigned 0 500 - - Probability FMB640
FMC640
FMM640
Permanent I/O elements
182 GNSS HDOP 2 Unsigned 0 500 - - Probability FMB640
FMC640
FMM640
Permanent I/O elements
66 External Voltage 2 Unsigned 0 30000 0,001 mV Voltage, mV FMB640
FMC640
FMM640
Permanent I/O elements
24 Speed 2 Unsigned 0 350 - km/h Value, km/h FMB640
FMC640
FMM640
Permanent I/O elements
205 GSM Cell ID 4 Unsigned 0 4294967295 - - GSM base station ID FMB640
FMC640
FMM640
Permanent I/O elements
206 GSM Area Code 2 Unsigned 0 65535 - - Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. FMB640
FMC640
FMM640
Permanent I/O elements
67 Battery Voltage 2 Unsigned 0 30000 0,001 mV Voltage, mV FMB640
FMC640
FMM640
Permanent I/O elements
68 Battery Current 2 Unsigned 0 2400 - mA Current, mA FMB640
FMC640
FMM640
Permanent I/O elements
241 Active GSM Operator 4 Unsigned 0 4294967295 - - Currently used GSM Operator code FMB640
FMC640
FMM640
Permanent I/O elements
199 Trip Odometer 4 Unsigned 0 4294967295 - m Trip Odometer value in meters FMB640
FMC640
FMM640
Permanent I/O elements
216 Total Odometer 4 Unsigned 0 4294967295 - m Total Odometer value in meters FMB640
FMC640
FMM640
Permanent I/O elements
1 Digital Input 1 1 Unsigned 0 1 - - Logic: 0/1 FMB640
FMC640
FMM640
Permanent I/O elements
9 Analog Input 1 2 Unsigned 0 30000 0,001 V Voltage, V FMB640
FMC640
FMM640
Permanent I/O elements
179 Digital Output 1 1 Unsigned 0 1 - - Logic: 0/1 FMB640
FMC640
FMM640
Permanent I/O elements
236 Axis X 2 Signed -8000 8000 - mG X axis value, mG FMB640
FMC640
FMM640
Permanent I/O elements
237 Axis Y 2 Signed -8000 8000 - mG Y axis value, mG FMB640
FMC640
FMM640
Permanent I/O elements
238 Axis Z 2 Signed -8000 8000 - mG Z axis value, mG FMB640
FMC640
FMM640
Permanent I/O elements
219 CCID Part1 8 Unsigned 0 0xffffffffffffffff - - Value of SIM ICCID FMB640
FMC640
FMM640
Permanent I/O elements
220 CCID Part2 8 Unsigned 0 0xffffffffffffffff - - Value of SIM ICCID FMB640
FMC640
FMM640
Permanent I/O elements
221 CCID Part3 8 Unsigned 0 0xffffffffffffffff - - Value of SIM ICCID FMB640
FMC640
FMM640
Permanent I/O elements
144 SD Status 1 Unsigned 0 1 - - Logic: 0 – not present, 1 – present FMB640
FMC640
FMM640
Permanent I/O elements
2 Digital Input 2 1 Unsigned 0 1 - - Logic: 0/1 FMB640
FMC640
FMM640
Permanent I/O elements
3 Digital Input 3 1 Unsigned 0 1 - - Logic: 0/1 FMB640
FMC640
FMM640
Permanent I/O elements
10 Analog Input 2 2 Unsigned 0 30000 0,001 V Voltage, V FMB640
FMC640
FMM640
Permanent I/O elements
180 Digital Output 2 1 Unsigned 0 1 - - Logic: 0/1 FMB640
FMC640
FMM640
Permanent I/O elements
72 Dallas Temperature 1 2 Signed -550 1150 0,1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

FMB640
FMC640
FMM640
Permanent I/O elements
73 Dallas Temperature 2 2 Signed -550 1150 0,1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

FMB640
FMC640
FMM640
Permanent I/O elements
74 Dallas Temperature 3 2 Signed -550 1150 0,1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

FMB640
FMC640
FMM640
Permanent I/O elements
75 Dallas Temperature 4 2 Signed -550 1150 0,1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

FMB640
FMC640
FMM640
Permanent I/O elements
62 Dallas Temperature ID 1 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID FMB640
FMC640
FMM640
Permanent I/O elements
63 Dallas Temperature ID 2 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID FMB640
FMC640
FMM640
Permanent I/O elements
64 Dallas Temperature ID 3 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID FMB640
FMC640
FMM640
Permanent I/O elements
65 Dallas Temperature ID 4 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID FMB640
FMC640
FMM640
Permanent I/O elements
78 iButton 8 Unsigned 0 0xffffffffffffffff - - iButton ID FMB640
FMC640
FMM640
Permanent I/O elements
76 Fuel Counter 4 Unsigned 0 4294967295 - - Number of impulses on selected input or difference between impulses on 2 lines

Read more about impulse counters here

FMB640
FMC640
FMM640
Permanent I/O elements
10640 Impulse counter frequency 1 4 Unsigned 0 4294967295 - Hz Impulse frequency of the selected input FMB640
FMC640
FMM640
Permanent I/O elements
10641 Impulse counter RPM 1 4 Unsigned 0 4294967295 - RPM Impulse RPM of the selected input FMB640
FMC640
FMM640
Permanent I/O elements
483 Impulse Counter 2 4 Unsigned 0 4294967295 - - Number of impulses on selected input FMB640
FMC640
FMM640
Permanent I/O elements
10642 Impulse counter frequency 2 4 Unsigned 0 4294967295 - Hz Impulse frequency of the selected input FMB640
FMC640
FMM640
Permanent I/O elements
10643 Impulse counter RPM 2 4 Unsigned 0 4294967295 - RPM Impulse RPM of the selected input FMB640
FMC640
FMM640
Permanent I/O elements
207 RFID 8 Unsigned 0 0xffffffffffffffff - - RFID ID FMB640
FMC640
FMM640
Permanent I/O elements
201 LLS 1 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS232 in kvants or liters FMB640
FMC640
FMM640
Permanent I/O elements
202 LLS 1 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS232 in degrees Celsius FMB640
FMC640
FMM640
Permanent I/O elements
203 LLS 2 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS232 in kvants or liters FMB640
FMC640
FMM640
Permanent I/O elements
204 LLS 2 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS232 in degrees Celsius FMB640
FMC640
FMM640
Permanent I/O elements
210 LLS 3 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS232 in kvants or liters FMB640
FMC640
FMM640
Permanent I/O elements
211 LLS 3 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS232 in degrees Celsius FMB640
FMC640
FMM640
Permanent I/O elements
212 LLS 4 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS232 in kvants or liters FMB640
FMC640
FMM640
Permanent I/O elements
213 LLS 4 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS232 in degrees Celsius FMB640
FMC640
FMM640
Permanent I/O elements
214 LLS 5 Fuel Level 2 Signed -4 32767 - kvants or ltr Fuel level measured by LLS sensor via RS232 in kvants or liters FMB640
FMC640
FMM640
Permanent I/O elements
215 LLS 5 Temperature 1 Signed -128 127 - °C Fuel temperature measured by LLS via RS232 in degrees Celsius FMB640
FMC640
FMM640
Permanent I/O elements
178 Network Type 1 Unsigned 0 4 - -

0 - 3G
1 - 2G
2 - 4G
3 - CAT M1
4 - CAT NB1

FMC640
FMM640
Permanent I/O elements
108 Number Of Records 4 Unsigned 0 65535 - h Record counter, counts records saved since startup. FMC640
FMM640
Permanent I/O elements
4 Digital Input 4 1 Unsigned 0 1 - - Logic: 0/1 FMB640
FMC640
FMM640
Permanent I/O elements
50 Digital Output 3 1 Unsigned 0 1 - - Logic: 0/1 FMB640
FMC640
FMM640
Permanent I/O elements
51 Digital Output 4 1 Unsigned 0 1 - - Logic: 0/1 FMB640
FMC640
FMM640
Permanent I/O elements
11 Analog Input 3 2 Unsigned 0 30000 0,001 V Voltage, V FMB640
FMC640
FMM640
Permanent I/O elements
245 Analog Input 4 2 Unsigned 0 30000 0,001 V Voltage, V FMB640
FMC640
FMM640
Permanent I/O elements
70 PCB Temperature 2 Signed -550 1150 0,1 °C Degrees ( °C ) FMB640
FMC640
FMM640
Permanent I/O elements
5 Dallas Temperature ID 5 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID FMB640
FMC640
FMM640
Permanent I/O elements
6 Dallas Temperature 5 2 Signed -550 1150 0,1 °C

Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

FMB640
FMC640
FMM640
Permanent I/O elements
7 Dallas Temperature ID 6 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID FMB640
FMC640
FMM640
Permanent I/O elements
8 Dallas Temperature 6 2 Signed -550 1150 0,1 °C

Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

FMB640
FMC640
FMM640
Permanent I/O elements
217 RFID COM2 8 Unsigned 0 0xffffffffffffffff - - RFID ID on COM2 FMB640
FMC640
FMM640
Permanent I/O elements
218 IMSI 8 Unsigned 0 0xffffffffffffffff - - International mobile subscriber identity FMB640
FMC640
FMM640
Permanent I/O elements
224 Ultrasonic Fuel Level 1 2 Signed -15 32767 0,1 mm FMB640
FMC640
FMM640
Permanent I/O elements
225 Ultrasonic Fuel Level 2 2 Signed -15 32767 0,1 mm FMB640
FMC640
FMM640
Permanent I/O elements
208 Ultrasonic Software Status 1 1 Unsigned 0 255 - -

0 – Software – Normal
1 – Software – The system has just started, output measurement value
2 – Software – Gas delay count
3 – Software – The measured value is invalid
4 – Software – The stationary state
5 – No data received for 50-60 seconds
9 – Software – a sudden drop
10 – Software – a sudden rise
11 – Software – delay time of the sudden drop
12 – Software – delay time of the sudden rise
13 – Software – The stationary state, maintain the liquid level height value outputu changed
15 – Software – A sudden drop/rise on an tilt

FMB640
FMC640
FMM640
Permanent I/O elements
209 Ultrasonic Software Status 2 1 Unsigned 0 255 - -

Values are identical to Ultrasonic Software Status 1

FMB640
FMC640
FMM640
Permanent I/O elements
484 External Sensor Temperature 1 2 Signed -32768 32767 - °C Degrees, °C FMB640
FMC640
FMM640
Permanent I/O elements
485 External Sensor Temperature 2 2 Signed -32768 32767 - °C Degrees, °C FMB640
FMC640
FMM640
Permanent I/O elements
486 External Sensor Temperature 3 2 Signed -32768 32767 - °C Degrees, °C FMB640
FMC640
FMM640
Permanent I/O elements
487 External Sensor Temperature 4 2 Signed -32768 32767 - °C Degrees, °C FMB640
FMC640
FMM640
Permanent I/O elements
488 External Sensor Temperature 5 2 Signed -32768 32767 - °C Degrees, °C FMB640
FMC640
FMM640
Permanent I/O elements
489 External Sensor Temperature 6 2 Signed -32768 32767 - °C Degrees, °C FMB640
FMC640
FMM640
Permanent I/O elements
701 BLE 1 temperature 2 Signed -400 1250 0,1 °C Degrees, °C, -40 - +125; Error codes:

4000 - abnormal sensor state 3000 - sensor not found 2000 - failed sensor data parsing

FMC640
FMM640
Permanent I/O elements
702 BLE 2 temperature 2 Signed -400 1250 0,1 °C Degrees, °C, -40 - +125; Error codes:

4000 - abnormal sensor state 3000 - sensor not found 2000 - failed sensor data parsing

FMC640
FMM640
Permanent I/O elements
703 BLE 3 temperature 2 Signed -400 1250 0,1 °C Degrees, °C, -40 - +125; Error codes:

4000 - abnormal sensor state 3000 - sensor not found 2000 - failed sensor data parsing

FMC640
FMM640
Permanent I/O elements
704 BLE 4 temperature 2 Signed -400 1250 0,1 °C Degrees, °C, -40 - +125; Error codes:

4000 - abnormal sensor state 3000 - sensor not found 2000 - failed sensor data parsing

FMC640
FMM640
Permanent I/O elements
705 BLE 1 Battery Voltage 1 Unsigned 0 100 - % Battery voltage of sensor #1 FMC640
FMM640
Permanent I/O elements
706 BLE 2 Battery Voltage 1 Unsigned 0 100 - % Battery voltage of sensor #2 FMC640
FMM640
Permanent I/O elements
707 BLE 3 Battery Voltage 1 Unsigned 0 100 - % Battery voltage of sensor #3 FMC640
FMM640
Permanent I/O elements
708 BLE 4 Battery Voltage 1 Unsigned 0 100 - % Battery voltage of sensor #4 FMC640
FMM640
Permanent I/O elements
709 BLE 1 Humidity 2 Unsigned 0 1000 0,1 %RH Humidity as measured by sensor #1 FMC640
FMM640
Permanent I/O elements
710 BLE 2 Humidity 2 Unsigned 0 1000 0,1 %RH Humidity as measured by sensor #2 FMC640
FMM640
Permanent I/O elements
711 BLE 3 Humidity 2 Unsigned 0 1000 0,1 %RH Humidity as measured by sensor #3 FMC640
FMM640
Permanent I/O elements
712 BLE 4 Humidity 2 Unsigned 0 1000 0,1 %RH Humidity as measured by sensor #4 FMC640
FMM640
Permanent I/O elements
713 BLE Sensor Custom 1 8 Unsigned 0 0xffffffffffffffff - - Raw data of 1st BLE sensor FMC640
FMM640
Permanent I/O elements
714 BLE Sensor Custom 2 8 Unsigned 0 0xffffffffffffffff - - Raw data of 2nd BLE sensor FMC640
FMM640
Permanent I/O elements
715 BLE Sensor Custom 3 8 Unsigned 0 0xffffffffffffffff - - Raw data of 3rd BLE sensor FMC640
FMM640
Permanent I/O elements
716 BLE Sensor Custom 4 8 Unsigned 0 0xffffffffffffffff - - Raw data of 4th BLE sensor FMC640
FMM640
Permanent I/O elements
717 BLE Luminosity 1 2 Unsigned 0 0xFFFF - - Luminosity value of a 1st BLE sensor FMC640
FMM640
Permanent I/O elements
718 BLE Luminosity 2 2 Unsigned 0 0xFFFF - - Luminosity value of a 2nd BLE sensor FMC640
FMM640
Permanent I/O elements
719 BLE Luminosity 3 2 Unsigned 0 0xFFFF - - Luminosity value of a 3rd BLE sensor FMC640
FMM640
Permanent I/O elements
720 BLE Luminosity 4 2 Unsigned 0 0xFFFF - - Luminosity value of a 4th BLE sensor FMC640
FMM640
Permanent I/O elements
721 BLE LLS Fuel 1 2 Unsigned 0 0xFFFF - - Fuel level of a 1st BLE sensor FMC640
FMM640
Permanent I/O elements
722 BLE LLS Fuel 2 2 Unsigned 0 0xFFFF - - Fuel level of a 2nd BLE sensor FMC640
FMM640
Permanent I/O elements
723 BLE LLS Fuel 3 2 Unsigned 0 0xFFFF - - Fuel level of a 3rd BLE sensor FMC640
FMM640
Permanent I/O elements
724 BLE LLS Fuel 4 2 Unsigned 0 0xFFFF - - Fuel level of a 4th BLE sensor FMC640
FMM640
Permanent I/O elements
725 BLE Frequency 1 4 Unsigned 0 0xFFFFFFFF - - Frequency value of BLE fuel sensor #1 FMC640
FMM640
Permanent I/O elements
726 BLE Frequency 2 4 Unsigned 0 0xFFFFFFFF - - Frequency value of BLE fuel sensor #2 FMC640
FMM640
Permanent I/O elements
727 BLE Frequency 3 4 Unsigned 0 0xFFFFFFFF - - Frequency value of BLE fuel sensor #3 FMC640
FMM640
Permanent I/O elements
728 BLE Frequency 4 4 Unsigned 0 0xFFFFFFFF - - Frequency value of BLE fuel sensor #4 FMC640
FMM640
Permanent I/O elements
729 BLE Sensor Custom 12 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
730 BLE Sensor Custom 13 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
731 BLE Sensor Custom 14 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
732 BLE Sensor Custom 15 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
733 BLE Sensor Custom 22 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
734 BLE Sensor Custom 23 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
735 BLE Sensor Custom 24 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
736 BLE Sensor Custom 25 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
737 BLE Sensor Custom 32 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
738 BLE Sensor Custom 33 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
739 BLE Sensor Custom 34 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
740 BLE Sensor Custom 35 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
741 BLE Sensor Custom 42 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
742 BLE Sensor Custom 43 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
743 BLE Sensor Custom 44 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
744 BLE Sensor Custom 45 4 Unsigned 0 0xFFFFFFFF - - RAW Data of BLE sensor FMC640
FMM640
Permanent I/O elements
10009 Eco score 2 Unsigned 0 65535 0,01 - Average amount of events on some distance FMB640
FMC640
FMM640
Permanent I/O elements
10487 1Wire Humidity 1 1 Unsigned 0 0xFF - % 1Wire Humidity 1 FMB640
FMC640
FMM640
Permanent I/O elements
10488 1Wire Humidity 2 1 Unsigned 0 0xFF - % 1Wire Humidity 2 FMB640
FMC640
FMM640
Permanent I/O elements
10489 1Wire Humidity 3 1 Unsigned 0 0xFF - % 1Wire Humidity 3 FMB640
FMC640
FMM640
Permanent I/O elements
10490 1Wire Humidity 4 1 Unsigned 0 0xFF - % 1Wire Humidity 4 FMB640
FMC640
FMM640
Permanent I/O elements
10491 1Wire Humidity 5 1 Unsigned 0 0xFF - % 1Wire Humidity 5 FMB640
FMC640
FMM640
Permanent I/O elements
10492 1Wire Humidity 6 1 Unsigned 0 0xFF - % 1Wire Humidity 1 FMB640
FMC640
FMM640
Permanent I/O elements


FMS elements

Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
79 Brake Switch 1 Unsigned 0 1 - -

0 - Pedal released
1 - Pedal pressed

FMB640
FMC640
FMM640
FMS elements
80 Wheel Based Speed 4 Unsigned 0 65536 - km/h FMB640
FMC640
FMM640
FMS elements
81 Cruise Control Active 1 Unsigned 0 1 - -

0 - Switched off
1 - Switched on

FMB640
FMC640
FMM640
FMS elements
82 Clutch Switch 1 Unsigned 0 1 - -

0 - Pedal released
1 - Pedal pressed

FMB640
FMC640
FMM640
FMS elements
83 PTO State 1 Unsigned 0 1 - -

0 - Off/disabled
1 - Set
2 - Not available

FMB640
FMC640
FMM640
FMS elements
84 Acceleration Pedal Position 4 Unsigned 0 102 - % FMB640
FMC640
FMM640
FMS elements
85 Engine Current Load 1 Unsigned 0 125 - % FMB640
FMC640
FMM640
FMS elements
86 Engine Total Fuel Used 4 Unsigned 0 2105540607 - l Value in liters, L FMB640
FMC640
FMM640
FMS elements
87 Fuel Level 4 Unsigned 0 102 - % FMB640
FMC640
FMM640
FMS elements
88 Engine Speed 4 Unsigned 0 8032 - rpm FMB640
FMC640
FMM640
FMS elements
89 Axle weight 1 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
90 Axle weight 2 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
91 Axle weight 3 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
92 Axle weight 4 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
93 Axle weight 5 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
94 Axle weight 6 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
95 Axle weight 7 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
96 Axle weight 8 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
97 Axle weight 9 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
98 Axle weight 10 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
99 Axle weight 11 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
100 Axle weight 12 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
101 Axle weight 13 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
102 Axle weight 14 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
103 Axle weight 15 2 Unsigned 0 32766 - kg FMB640
FMC640
FMM640
FMS elements
104 Engine Total Hours Of Operation 4 Unsigned 0 214748364 - h FMB640
FMC640
FMM640
FMS elements
109 Software Version Supported 4 Unsigned 0 0xffffffff - -

Format: ab.cd
ab = byte1 byte2
cd = byte3 byte4

FMB640
FMC640
FMM640
FMS elements
110 Diagnostics Supported 1 Unsigned 0 3 - -

0 - Diagnostics is not supported
1 - Diagnostics is supported
2 - Reserved
3 - Do not care

FMB640
FMC640
FMM640
FMS elements
111 Requests Supported 1 Unsigned 0 3 - -

0 - Request is not supported
1 - Request is supported
2 - Reserved
3 - Do not care

FMB640
FMC640
FMM640
FMS elements
113 Service Distance 4 Signed -160635 167040 - km FMB640
FMC640
FMM640
FMS elements
122 Direction Indication 1 Unsigned 0 1 - -

0 - Vehicle is moving Forward
1 - Reverse

FMB640
FMC640
FMM640
FMS elements
123 Tachograph Performance 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
FMS elements
124 Handling Info 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
FMS elements
125 System Event 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
FMS elements
127 Engine Coolant Temperature 1 Signed -40 210 - °C Offset by -40 FMB640
FMC640
FMM640
FMS elements
128 Ambient Air Temperature 2 Signed -273 1770 - °C FMB640
FMC640
FMM640
FMS elements
135 Fuel Rate 4 Unsigned 0 3212 - l/h FMB640
FMC640
FMM640
FMS elements
136 Instantaneous Fuel Economy 4 Unsigned 0 125 - km/l FMB640
FMC640
FMM640
FMS elements
137 PTO Drive Engagement 1 Unsigned 0 3 - -

0 - No PTO drive is engaged
1 - At least one PTO drive is engaged
2 - Error
3 - Not available

FMB640
FMC640
FMM640
FMS elements
138 High Resolution Engine Total Fuel Used 4 Unsigned 0 4211081.215 - l or ml Resolution in l or ml depending on the FMS fuel settings (item id 121) FMB640
FMC640
FMM640
FMS elements
139 Gross Combination Vehicle Weight 4 Unsigned 0 642550 - kg The total weight of the truck and all attached trailers. FMB640
FMC640
FMM640
FMS elements
229 AdBlue status 1 Unsigned 0 3 - -

0 - Off
1 - Cond. Red
2 - Cond. Yellow
3 - Cond. info

FMB640
FMC640
FMM640
FMS elements
357 Brake Pedal Position 1 Unsigned 0 100 - % The ratio of current brake pedal position to the maximum possible position FMB640
FMC640
FMM640
FMS elements
10348 Fuel level 2 1 Unsigned 0 100 - % This parameter shows fuel level in secondary tank (if fuel type is different then currently used fuel) FMB640
FMC640
FMM640
FMS elements
10349 MIL indicator 1 Unsigned 0 100 - -

0 - OFF
1 - Condition Red
2 - Condition Yellow
3 - Condition Info
7 - Not Available

There are three possible conditions stated: Red, Yellow, Info. The interpretation of the status is manufacturer dependant and might be different. For details please refer to the manufacturer’s document.

FMB640
FMC640
FMM640
FMS elements
10428 Tell Tale 0 8 HEX 0 0xffffffffffffffff - - IO element describes Tell Tale Block ID message received from Block ID 0 in Hexadecimal format. FMB640
FMC640
FMM640
FMS elements
10429 Tell Tale 1 8 HEX 0 0xffffffffffffffff - - IO element describes Tell Tale Block ID message received from Block ID 1 in Hexadecimal format. FMB640
FMC640
FMM640
FMS elements
10430 Tell Tale 2 8 HEX 0 0xffffffffffffffff - - IO element describes Tell Tale Block ID message received from Block ID 2 in Hexadecimal format. FMB640
FMC640
FMM640
FMS elements
10431 Tell Tale 3 8 HEX 0 0xffffffffffffffff - - IO element describes Tell Tale Block ID message received from Block ID 3 in Hexadecimal format. FMB640
FMC640
FMM640
FMS elements

CAN adapters elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
12 Program Number 2 Unsigned 0 999 - - Value: Min – 0, Max – 999 FMB640
FMC640
FMM640
CAN adapters elements
13 Module ID 8 Unsigned 0 0xffffffffffffffff - - Module ID FMB640
FMC640
FMM640
CAN adapters elements
14 Engine Worktime 4 Unsigned 0 16777215 - min Engine work time in minutes FMB640
FMC640
FMM640
CAN adapters elements
15 Engine Worktime (Counted) 4 Unsigned 0 16777215 - min Total Engine work time in minutes FMB640
FMC640
FMM640
CAN adapters elements
16 Total Mileage (Counted) 4 Unsigned 0 4294967295 - m Total Vehicle Mileage, m FMB640
FMC640
FMM640
CAN adapters elements
17 Fuel Consumed (counted) 4 Unsigned 0 2147483647 0,1 l Total Fuel Consumed, l FMB640
FMC640
FMM640
CAN adapters elements
18 Fuel Rate 2 Unsigned 0 32768 0,1 l/h Fuel Rate l/h FMB640
FMC640
FMM640
CAN adapters elements
19 AdBlue Level Percent 1 Unsigned 0 255 0,4 % AdBlue, % FMB640
FMC640
FMM640
CAN adapters elements
20 AdBlue Level Liters 2 Unsigned 0 65535 0,1 l AdBlue level, L FMB640
FMC640
FMM640
CAN adapters elements
23 Engine Load 1 Unsigned 0 130 - % Engine load, % FMB640
FMC640
FMM640
CAN adapters elements
25 Engine Temperature 2 Signed -600 1270 0,1 °C Engine Temperature, °C FMB640
FMC640
FMM640
CAN adapters elements
26 Axle 1 Load 2 Unsigned 0 32768 - kg Axle 1 load, kg FMB640
FMC640
FMM640
CAN adapters elements
27 Axle 2 Load 2 Unsigned 0 32768 - kg Axle 2 load, kg FMB640
FMC640
FMM640
CAN adapters elements
28 Axle 3 Load 2 Unsigned 0 32768 - kg Axle 3 load, kg FMB640
FMC640
FMM640
CAN adapters elements
29 Axle 4 Load 2 Unsigned 0 32768 - kg Axle 4 load, kg FMB640
FMC640
FMM640
CAN adapters elements
30 Vehicle Speed 1 Unsigned 0 255 - km/h Value in km/h FMB640
FMC640
FMM640
CAN adapters elements
31 Accelerator Pedal Position 1 Unsigned 0 255 0,4 % Value in persentages, % FMB640
FMC640
FMM640
CAN adapters elements
32 Axle 5 Load 2 Unsigned 0 32768 - kg Axle 5 load, kg FMB640
FMC640
FMM640
CAN adapters elements
33 Fuel Consumed 4 Unsigned 0 2147483647 0,1 l Value in liters, L FMB640
FMC640
FMM640
CAN adapters elements
34 Fuel Level Liters 2 Unsigned 0 65535 0,1 l Value in liters, L FMB640
FMC640
FMM640
CAN adapters elements
35 Engine RPM 2 Unsigned 0 16384 - rpm Value in rounds per minute, rpm FMB640
FMC640
FMM640
CAN adapters elements
36 Total Mileage 4 Unsigned 0 4294967295 - m Value in meters, m FMB640
FMC640
FMM640
CAN adapters elements
37 Fuel Level Percent 1 Unsigned 0 255 0,4 % Value in percentages, % FMB640
FMC640
FMM640
CAN adapters elements
38 Control State Flags 4 Unsigned 0 4294967295 - - Control State Flags FMB640
FMC640
FMM640
CAN adapters elements
39 Agricultural Machinery Flags 8 Unsigned 0 0xffffffffffffffff - - Agricultural machinery flags FMB640
FMC640
FMM640
CAN adapters elements
40 Harvesting Time 4 Unsigned 0 16777215 - min Harvesting time, minutes FMB640
FMC640
FMM640
CAN adapters elements
41 Area of Harvest 4 Unsigned 0 4294967295 - m2 Area of Harvest, m2 FMB640
FMC640
FMM640
CAN adapters elements
42 Mowing Efficiency 4 Unsigned 0 4294967295 - m2/h Mowing efficiency, (m^2)/h FMB640
FMC640
FMM640
CAN adapters elements
43 Grain Mown Volume 4 Unsigned 0 4294967295 - kg Mown Volume, kg FMB640
FMC640
FMM640
CAN adapters elements
44 Grain Moisture 2 Unsigned 0 65535 0,1 % Grain Moisture in proc, % FMB640
FMC640
FMM640
CAN adapters elements
45 Harvesting Drum RPM 2 Unsigned 0 65535 - rpm Harvesting Drum RPM, RPM FMB640
FMC640
FMM640
CAN adapters elements
46 Gap Under Harvesting Drum 1 Unsigned 0 255 - mm Gap Under Harvesting Drum, mm FMB640
FMC640
FMM640
CAN adapters elements
47 Security State Flags 8 Unsigned 0 0xffffffffffffffff - - Security State Flag FMB640
FMC640
FMM640
CAN adapters elements
141 Battery Temperature 2 Unsigned -600 1270 0,1 °C Degrees, °C FMB640
FMC640
FMM640
CAN adapters elements
142 Battery Level Percent 1 Unsigned 0 255 0,4 % Value in percentages, % FMB640
FMC640
FMM640
CAN adapters elements
143 Door Status 2 Unsigned 0 16128 - -

Min – 0, Max – 16128
Door status is represented as bitmask converted to decimal value.
Possible values:
0 – all doors closed,
0x100 (256) – front left door is opened,
0x200 (512) – front right door is opened,
0x400 (1024) – rear left door is opened,
0x800 (2048) – rear right door is opened,
0x1000 (4096) – hood is opened,
0x2000 (8192) – trunk is opened,
0x3F00 (16128) – all doors are opened, or combinations of values

FMB640
FMC640
FMM640
CAN adapters elements
176 DTC Errors 1 Unsigned 0 255 - - DTC Errors FMB640
FMC640
FMM640
CAN adapters elements
527 DTC Value Variable Unsigned - - - - FMB640
FMC640
FMM640
CAN adapters elements
226 CNG Status 1 Unsigned 0 1 - -

0 - Engine not on CNG;
1 - Engine on CNG.

FMB640
FMC640
FMM640
CAN adapters elements
227 CNG Used 4 Unsigned 0 4294967295 - kg CNG Used FMB640
FMC640
FMM640
CAN adapters elements
228 CNG Level 2 Unsigned 0 65535 - % CNG Level FMB640
FMC640
FMM640
CAN adapters elements
500 Slope Of Arm 2 Signed -3276 3276 - ° Slope Of Arm, degrees ° FMB640
FMC640
FMM640
CAN adapters elements
501 Rotation Of Arm 2 Signed -180 180 - ° Rotation Of Arm, degrees ° FMB640
FMC640
FMM640
CAN adapters elements
502 Eject Of Arm 2 Unsigned 0 6553 - m Eject Of Arm, m FMB640
FMC640
FMM640
CAN adapters elements
503 Horizontal Distance Arm 2 Unsigned 0 6553 - m Horizontal Distance Arm Vehicle, m FMB640
FMC640
FMM640
CAN adapters elements
504 Height Arm Above Ground 2 Unsigned 0 6553 - m Height Arm Above ground, m FMB640
FMC640
FMM640
CAN adapters elements
505 Drill RPM 2 Unsigned 0 65535 - rpm Drill RPM, RPM FMB640
FMC640
FMM640
CAN adapters elements
506 Spread Salt 2 Unsigned 0 655 - g/m2 Amount Of Spread Salt Square Meter, g/m2 FMB640
FMC640
FMM640
CAN adapters elements
507 Battery Voltage 2 Unsigned 0 6553 - V Battery Voltage, V FMB640
FMC640
FMM640
CAN adapters elements
508 Spread Fine Grained Salt 4 Unsigned 0 1677722 - T Amount Of Spread Fine Grained Salt, T FMB640
FMC640
FMM640
CAN adapters elements
509 Coarse Grained Salt 4 Unsigned 0 1677722 - T Amount Of Coarsed Grained Salt, T FMB640
FMC640
FMM640
CAN adapters elements
510 Spread DiMix 4 Unsigned 0 1677722 - T Amount Of Spread DiMix, T FMB640
FMC640
FMM640
CAN adapters elements
511 Spread Coarse Grained Calcium 4 Unsigned 0 1677722 - m2 Amount Of Spread Coarse Grained Calcium, m2 FMB640
FMC640
FMM640
CAN adapters elements
512 Spread Calcium Chloride 4 Unsigned 0 1677722 - m2 Amount Of Spread Calcium Chloride, m2 FMB640
FMC640
FMM640
CAN adapters elements
513 Spread Sodium Chloride 4 Unsigned 0 1677722 - m2 Amount Of Spread Sodium Chloride, m2 FMB640
FMC640
FMM640
CAN adapters elements
514 Spread Magnesium Chloride, m2 4 Unsigned 0 1677722 - m2 Amount Of Spread Magnesium Chloride, m2 FMB640
FMC640
FMM640
CAN adapters elements
515 Amount Of Spread Gravel 4 Unsigned 0 1677722 - T Amount Of Spread Gravel, T FMB640
FMC640
FMM640
CAN adapters elements
516 Amount Of Spread Sand 4 Unsigned 0 1677722 - T Amount Of Spread Sand, T FMB640
FMC640
FMM640
CAN adapters elements
517 Width Pouring Left 2 Unsigned 0 655 - m Width pouring left, m FMB640
FMC640
FMM640
CAN adapters elements
518 Width Pouring Right 2 Unsigned 0 655 - m Width pouring right, m FMB640
FMC640
FMM640
CAN adapters elements
519 Salt Spreader Working Hours 4 Unsigned 0 1677722 - h Salt Spreader Working Hours, h FMB640
FMC640
FMM640
CAN adapters elements
520 Distance During Salting 4 Unsigned 0 1677722 - km Distance During salting, km FMB640
FMC640
FMM640
CAN adapters elements
521 Load Weight 4 Unsigned 0 16777215 - kg Load Weight, kg FMB640
FMC640
FMM640
CAN adapters elements
522 Retarder Load 1 Unsigned 0 130 - % Retarder Load, % FMB640
FMC640
FMM640
CAN adapters elements
523 Cruise Time 4 Unsigned 0 16777215 - min Cruise time, minutes FMB640
FMC640
FMM640
CAN adapters elements
524 Engine Oil Level 1 Unsigned 0 255 - - Oil level FMB640
FMC640
FMM640
CAN adapters elements
525 Fault Codes 128 ASCII 0 128 - - Fault Codes (values seperated via ".") FMB640
FMC640
FMM640
CAN adapters elements
526 Vehicles Range On Battery 4 Unsigned 0 16777215 - m Vehicles Range On Battery FMB640
FMC640
FMM640
CAN adapters elements
527 Vehicles Range On Additional Fuel 4 Unsigned 0 2147483647 - m Vehicles Range On Additional Fuel FMB640
FMC640
FMM640
CAN adapters elements
528 VIN 17 ASCII 0 0xFF - - VIN number FMB640
FMC640
FMM640
CAN adapters elements
529 Module ID 17B 17 HEX 0 0x7fffffffffffffff - - Module ID 17 bytes FMB640
FMC640
FMM640
CAN adapters elements
10631 LVCAN Driver Seatbelt 1 Unsigned 0 1 - - Driver Seatbelt FMB640
FMC640
FMM640
CAN adapters elements
10632 LVCAN Front Passenger Seatbelt 1 Unsigned 0 1 - - Front Passenger Seatbelt FMB640
FMC640
FMM640
CAN adapters elements

Eventual I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
52 Tacho drive no card 1 Unsigned 0 1 - -

0 – No card stop
1 – No card start

FMB640
FMC640
FMM640
Eventual I/O elements
70 PCB Temperature 2 Signed -550 1150 0,1 °C Degrees ( °C ) FMB640
FMC640
FMM640
Eventual I/O elements
155 Geofence zone 01 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
156 Geofence zone 02 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
157 Geofence zone 03 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
158 Geofence zone 04 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
159 Geofence zone 05 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
160 Geofence zone 06 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
161 Geofence zone 07 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
162 Geofence zone 08 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
163 Geofence zone 09 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
164 Geofence zone 10 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
165 Geofence zone 11 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
166 Geofence zone 12 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
167 Geofence zone 13 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
168 Geofence zone 14 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
169 Geofence zone 15 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
170 Geofence zone 16 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
171 Geofence zone 17 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
172 Geofence zone 18 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
173 Geofence zone 19 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
174 Geofence zone 20 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
327 Geofence zone 21 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
328 Geofence zone 22 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
329 Geofence zone 23 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
330 Geofence zone 24 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
331 Geofence zone 25 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
332 Geofence zone 26 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
333 Geofence zone 27 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
334 Geofence zone 28 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
335 Geofence zone 29 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
336 Geofence zone 30 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
337 Geofence zone 31 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
338 Geofence zone 32 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
339 Geofence zone 33 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
340 Geofence zone 34 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
341 Geofence zone 35 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
342 Geofence zone 36 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
343 Geofence zone 37 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
344 Geofence zone 38 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
345 Geofence zone 39 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
346 Geofence zone 40 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
347 Geofence zone 41 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
348 Geofence zone 42 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
349 Geofence zone 43 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
350 Geofence zone 44 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
351 Geofence zone 45 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
352 Geofence zone 46 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
353 Geofence zone 47 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
354 Geofence zone 48 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
355 Geofence zone 49 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
356 Geofence zone 50 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
550 Geofence zone 51 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
551 Geofence zone 52 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
552 Geofence zone 53 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
553 Geofence zone 54 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
554 Geofence zone 55 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
555 Geofence zone 56 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
556 Geofence zone 57 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
557 Geofence zone 58 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
558 Geofence zone 59 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
559 Geofence zone 60 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
560 Geofence zone 61 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
561 Geofence zone 62 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
562 Geofence zone 63 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
563 Geofence zone 64 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
564 Geofence zone 65 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
565 Geofence zone 66 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
566 Geofence zone 67 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
567 Geofence zone 68 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
568 Geofence zone 69 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
569 Geofence zone 70 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
570 Geofence zone 71 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
571 Geofence zone 72 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
572 Geofence zone 73 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
573 Geofence zone 74 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
574 Geofence zone 75 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
575 Geofence zone 76 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
576 Geofence zone 77 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
577 Geofence zone 78 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
578 Geofence zone 79 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
579 Geofence zone 80 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
580 Geofence zone 81 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
581 Geofence zone 82 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
582 Geofence zone 83 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
583 Geofence zone 84 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
584 Geofence zone 85 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
585 Geofence zone 86 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
586 Geofence zone 87 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
587 Geofence zone 88 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
588 Geofence zone 89 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
589 Geofence zone 90 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
590 Geofence zone 91 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
591 Geofence zone 92 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
592 Geofence zone 93 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
593 Geofence zone 94 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
594 Geofence zone 95 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone


FMB640
FMC640
FMM640
Eventual I/O elements
595 Geofence zone 96 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
596 Geofence zone 97 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
597 Geofence zone 98 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone


FMB640
FMC640
FMM640
Eventual I/O elements
598 Geofence zone 99 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
599 Geofence zone 100 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
175 Auto Geofence 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

FMB640
FMC640
FMM640
Eventual I/O elements
250 Trip 1 Unsigned 0 1 - -

1 – trip start;
0 – trip stop.

FMB640
FMC640
FMM640
Permanent I/O elements
255 Over Speeding 1 Unsigned 0 255 - km/h At over speeding start km/h, at over speeding end km/h FMB640
FMC640
FMM640
Eventual I/O elements
257 Crash Trace Data 466 HEX 0 466 - - Crash Trace Data FMB640
FMC640
FMM640
Permanent I/O elements
258 EcoMaximum 8 Unsigned 0 0xffffffffffffffff - -

Element stores maximum accelerometer values in mg on all axis during Eco driving event 8 Bytes: 2B Zeros 2B - X axis 2B - Y axis 2B - Z axis

FMB640
FMC640
FMM640
Permanent I/O elements
259 EcoAverage 8 Unsigned 0 0xffffffffffffffff - -

Element stores average accelerometer values in mg on all axis during Eco 8 Bytes: 2B Zeros 2B - X axis 2B - Y axis 2B - Z axis

FMB640
FMC640
FMM640
Permanent I/O elements
260 EcoDuration 2 Unsigned 0 65535 - - Duration of Eco driving in miliseconds. FMB640
FMC640
FMM640
Permanent I/O elements
243 Idling 1 Unsigned 0 1 - -

0 – moving,
1 – idling

FMB640
FMC640
FMM640
Eventual I/O elements
244 Camera Image Generated 4 Unsigned 0 4294967295 - -

Image id is timestamp value

FMB640
FMC640
FMM640
Eventual I/O elements
253 Green Driving Type 1 Unsigned 1 3 - -

1 – harsh acceleration,
2 – harsh braking,
3 – harsh cornering

FMB640
FMC640
FMM640
Eventual I/O elements
246 Towing 1 Unsigned 0 1 - -

0 – steady,
1 – towing

FMB640
FMC640
FMM640
Eventual I/O elements
248 Geofence Zone Over Speeding 1 Unsigned 0 255 - - Number of Geofence Zone where Over Speeding is detected FMB640
FMC640
FMM640
Eventual I/O elements
247 Crash Detection 1 Unsigned 0 5 - -

1 – Crash detected
2 – limited crash trace (device not calibrated)
3 - limited crash trace (device is calibrated)
4 - full crash trace (device not calibrated)
5 - full crash trace (device is calibrated)

FMB640
FMC640
FMM640
Eventual I/O elements
251 Immobilizer 1 Unsigned 0 3 - -

0 – iButton not connected
1 – iButton connected (Immobilizer)
2 – iButton connected (Authorized Driving)
3 - Authorization timeout

FMB640
FMC640
FMM640
Eventual I/O elements
254 Green Driving Value 1 Unsigned 0 255 acc and braking: 0.01 G or rad Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g), if harsh cornering – degrees (value in radians) FMB640
FMC640
FMM640
Eventual I/O elements
249 Jamming 1 Unsigned 0 1 - -

1 – jamming start
0 – jamming stop

FMB640
FMC640
FMM640
Eventual I/O elements
252 Authorized Driving 1 Unsigned 0 3 - -

0 – iButton not connected
1 – authorized iButton connected
2 – non authorized ibutton attached
3 - authorization timeout

FMB640
FMC640
FMM640
Eventual I/O elements
242 Data Limit Hit 1 Unsigned 0 1 - -

0 - Data limit hit in home;
1 - Data limit hit in roaming.

FMB640
FMC640
FMM640
Eventual I/O elements
358 Custom Scenario 1 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Eventual I/O elements
359 Custom Scenario 2 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Eventual I/O elements
360 Custom Scenario 3 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Eventual I/O elements
361 Custom Scenario 4 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Eventual I/O elements
10500 BLE Advertisement data 198 HEX 0 198 - - List of parsed advertising data of BLE beacons (Eddystone and iBeacon) found by BLE scanning FMB640
FMC640
FMM640
Permanent I/O elements
10611 RS232_COM1Data 200 HEX 0 200 - - RS232_COM1Data to IO FMB640
FMC640
FMM640
Permanent I/O elements
10612 RS232_COM2Data 200 HEX 0 200 - - RS232_COM2Data to IO FMB640
FMC640
FMM640
Permanent I/O elements

Manual CAN elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
145 Manual CAN 00 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
146 Manual CAN 01 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
147 Manual CAN 02 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
148 Manual CAN 03 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
149 Manual CAN 04 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
150 Manual CAN 05 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
151 Manual CAN 06 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
152 Manual CAN 07 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
153 Manual CAN 08 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
154 Manual CAN 09 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
380 Manual CAN 10 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
381 Manual CAN 11 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
382 Manual CAN 12 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
383 Manual CAN 13 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
384 Manual CAN 14 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
385 Manual CAN 15 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
386 Manual CAN 16 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
387 Manual CAN 17 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
388 Manual CAN 18 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
389 Manual CAN 19 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10298 Manual CAN 20 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10299 Manual CAN 21 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10300 Manual CAN 22 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10301 Manual CAN 23 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10302 Manual CAN 24 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10303 Manual CAN 25 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10304 Manual CAN 26 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10305 Manual CAN 27 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10306 Manual CAN 28 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10307 Manual CAN 29 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10308 Manual CAN 30 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10309 Manual CAN 31 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10310 Manual CAN 32 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10311 Manual CAN 33 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10312 Manual CAN 34 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10313 Manual CAN 35 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10314 Manual CAN 36 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10315 Manual CAN 37 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10316 Manual CAN 38 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10317 Manual CAN 39 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10318 Manual CAN 40 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10319 Manual CAN 41 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10320 Manual CAN 42 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10321 Manual CAN 43 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10322 Manual CAN 44 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10323 Manual CAN 45 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10324 Manual CAN 46 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10325 Manual CAN 47 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10326 Manual CAN 48 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10327 Manual CAN 49 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10328 Manual CAN 50 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10329 Manual CAN 51 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10330 Manual CAN 52 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10331 Manual CAN 53 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10332 Manual CAN 54 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10333 Manual CAN 55 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10334 Manual CAN 56 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10335 Manual CAN 57 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10336 Manual CAN 58 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10337 Manual CAN 59 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10338 Manual CAN 60 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10339 Manual CAN 61 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10340 Manual CAN 62 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10341 Manual CAN 63 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10342 Manual CAN 64 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10343 Manual CAN 65 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10344 Manual CAN 66 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10345 Manual CAN 67 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10346 Manual CAN 68 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10347 Manual CAN 69 1-8 Unsigned 0 0xffffffffffffffff - - FMB640
FMC640
FMM640
Manual CAN elements
10358 Manual CAN Extended 224 HEX 0 224 - - Variable size FMB640
FMC640
FMM640
Manual CAN elements

Tachograph data elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
183 Drive Recognize 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Tachograph data elements
184 Driver 1 Working State 1 Unsigned 0 7 - -

Parameter shall indicate the state of work of driver 1, i.e. activity currently selected on the recording unit for the driver.
0 - Rest;
1 - Driver available
2 - Work;
3 - Drive;
6 - Error;
7 - Not available.

FMB640
FMC640
FMM640
Tachograph data elements
185 Driver 2 Working State 1 Unsigned 0 7 - -

Parameter shall indicate the state of work of driver 2, i.e. activity currently selected on the recording unit for the driver.
0 - Rest;
1 - Driver available
2 - Work;
3 - Drive;
6 - Error;
7 - Not available.

FMB640
FMC640
FMM640
Tachograph data elements
186 Tachograph Over Speed 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Tachograph data elements
187 Driver 1 Card Presence 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Tachograph data elements
188 Driver 2 Card Presence 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Tachograph data elements
189 Driver 1 Time Related States 1 Unsigned 0 15 - -

0 – normal;
1 – 15 min before 4.5h;
2 – 4.5h reached;
3 – 15 min before 9h;
4 – 9 h reached;
5 – 15 min before 16h;
6 – 16h reached;
7 – weekly driving time pre-warning active;
8 - weekly driving time warning active;
9 - 2 weeks driving time pre-warning active;
10 - 2 weeks driving time warning active;
11 - driver 1 card expiry warning active;
12 - next mandatory driver 1 card download warning active;
13 – Other;
14 – Error;
15 – Not available..

FMB640
FMC640
FMM640
Tachograph data elements
190 Driver 2 Time Related States 1 Unsigned 0 15 - -

0 – normal;
1 – 15 min before 4.5h;
2 – 4.5h reached;
3 – 15 min before 9h;
4 – 9 h reached;
5 – 15 min before 16h;
6 – 16h reached;
7 – weekly driving time pre-warning active;
8 - weekly driving time warning active;
9 - 2 weeks driving time pre-warning active;
10 - 2 weeks driving time warning active;
11 - driver 2 card expiry warning active;
12 - next mandatory driver 2 card download warning active;
13 – Other;
14 – Error;
15 – Not available..

FMB640
FMC640
FMM640
Tachograph data elements
191 Vehicle Speed 2 Unsigned 0 65535 - km/h FMB640
FMC640
FMM640
Tachograph data elements
192 Odometer 4 Unsigned 0 4294967295 - m Total vehicle distance FMB640
FMC640
FMM640
Tachograph data elements
193 Trip Distance 4 Unsigned 0 4294967295 - m Current vehicle distance FMB640
FMC640
FMM640
Tachograph data elements
194 Timestamp 4 Unsigned 0 4294967295 - - How to read Timestamp FMB640
FMC640
FMM640
Tachograph data elements
231 Vehicle Registration Number Part1 8 Unsigned 0 0xffffffffffffffff - - ASCII bytes FMB640
FMC640
FMM640
Tachograph data elements
232 Vehicle Registration Number Part2 8 Unsigned 0 0xffffffffffffffff - - ASCII bytes FMB640
FMC640
FMM640
Tachograph data elements
233 Vehicle Identification Number Part1 8 Unsigned 0 0xffffffffffffffff - - ASCII bytes FMB640
FMC640
FMM640
Tachograph data elements
234 Vehicle Identification Number Part2 8 Unsigned 0 0xffffffffffffffff - - ASCII bytes FMB640
FMC640
FMM640
Tachograph data elements
235 Vehicle Identification Number Part3 1 Unsigned 0 0xff - - ASCII bytes FMB640
FMC640
FMM640
Tachograph data elements
222 Card 1 Issuing Member State 1 Unsigned 0 255 - - NationNumeric as described in EEC 3821_85 FMB640
FMC640
FMM640
Tachograph data elements
223 Card 2 Issuing Member State 1 Unsigned 0 255 - - NationNumeric as described in EEC 3821_85 FMB640
FMC640
FMM640
Tachograph data elements
195 Driver 1 ID MSB 8 Unsigned 0 0xffffffffffffffff - - How to read Driver ID FMB640
FMC640
FMM640
Tachograph data elements
196 Driver 1 ID LSB 8 Unsigned 0 0xffffffffffffffff - - How to read Driver ID FMB640
FMC640
FMM640
Tachograph data elements
197 Driver 2 ID MSB 8 Unsigned 0 0xffffffffffffffff - - How to read Driver ID FMB640
FMC640
FMM640
Tachograph data elements
198 Driver 2 ID LSB 8 Unsigned 0 0xffffffffffffffff - - How to read Driver ID FMB640
FMC640
FMM640
Tachograph data elements
56 Driver 1 Continuous Driving Time 2 Unsigned 0 0xffff - Minutes This parameter shall be computed as the current accumulated driving times of a particular drive. FMB640
FMC640
FMM640
Tachograph data elements
57 Driver 2 Continuous Driving Time 2 Unsigned 0 0xffff - Minutes This parameter shall be defined as Driver 2 continuous driving time. FMB640
FMC640
FMM640
Tachograph data elements
58 Driver 1 Cumulative Break Time 2 Unsigned 0 0xffff - Minutes This parameter shall indicate the uninterrupted break time for driver 1 as defined by legal regulation. FMB640
FMC640
FMM640
Tachograph data elements
59 Driver 2 Cumulative Break Time 2 Unsigned 0 0xffff - Minutes This parameter shall indicate the uninterrupted break time for driver 2 as defined by legal regulation. FMB640
FMC640
FMM640
Tachograph data elements
60 Driver 1 Selected Activity Duration 2 Unsigned 0 0xffff - Minutes Parameter shall indicate the current duration of the selected activity, since selected and which may be the current driving period, availability period, rest period or work period. FMB640
FMC640
FMM640
Tachograph data elements
61 Driver 2 Selected Activity Duration 2 Unsigned 0 0xffff - Minutes Parameter shall indicate the current duration of the selected activity, since selected and which may be the current driving period, availability period, rest period or work period. FMB640
FMC640
FMM640
Tachograph data elements
69 Driver 1 Cumulative Driving Time 2 Unsigned 0 0xffff - Minutes Parameter shall be computed as the current accumulated driving times of driver 1 (driver), for the previous and the current week. FMB640
FMC640
FMM640
Tachograph data elements
77 Driver 2 Cumulative Driving Time 2 Unsigned 0 0xffff - Minutes Parameter shall be computed as the current accumulated driving times of driver 2 (driver), for the previous and the current week. FMB640
FMC640
FMM640
Tachograph data elements
48 Tacho Data Source 1 Unsigned 0 4 - -

As possible select different sources from which tacho data will be readed, this parameter indicate from which source data is read.
0 - Unknown (data is not available);
1 - K-Line;
2 - ALL-CAN300;
3 - TachoCAN;
4 - FMS.

FMB640
FMC640
FMM640
Tachograph data elements
10501 Drivers hours rules pre warning time delay 1 Unsigned 0 255 - Minutes This parameter shall be the time delay between a pre-warning and the associated warning for daily driving time, weekly driving time, two weeks driving time, and time to start daily/weekly rest period

Operating range 15-60 min

FMB640
FMC640
FMM640
Tachograph data elements
10502 Out Of Scope Condition 1 Unsigned 0 255 - - This parameter shall be used to indicate whether an out of scope specific condition is currently open.

Value:
00 — no out of scope condition opened;
01 — out of scope condition opened.

FMB640
FMC640
FMM640
Tachograph data elements
10503 Next Calibration Date 4 Unsigned 0 4294967295 - Timestamp This parameter shall be used to indicate next mandatory calibration date of the tachograph and shall becarried out by the authorized inspection authority.

Value: Byte 1 — month; Byte 2 — day; Byte 3 — year How to parse Next Calibration Date

FMB640
FMC640
FMM640
Tachograph data elements
10504 Driver 1 end of last daily rest report 4 Unsigned 0 4294967295 - Timestamp This parameter shall be the end of the last daily rest period of driver 1, as computed by the tachograph using driver 1 card data. How to read Timestamp FMB640
FMC640
FMM640
Tachograph data elements
10505 Driver 1 end of last weekly rest period 4 Unsigned 0 4294967295 - Timestamp This parameter shall be the end of the last weekly rest period of driver 1, as computed by the tachograph

using driver 1 card data. How to read Timestamp

FMB640
FMC640
FMM640
Tachograph data elements
10506 Driver 1 end of second last weekly rest period 4 Unsigned 0 4294967295 - Timestamp This parameter shall be the end of the second last weekly rest period of driver 1, as computed by the tachograph using driver 1 card data. How to read Timestamp FMB640
FMC640
FMM640
Tachograph data elements
10507 Driver 1 current daily driving time 2 Unsigned 0 65535 - Minutes This parameter shall be the current daily driving time of driver 1, as computed by the tachograph using driver 1 card data. FMB640
FMC640
FMM640
Tachograph data elements
10508 Driver 1 current weekly driving time 2 Unsigned 0 65535 - Minutes This parameter shall be the current weekly driving time of driver 1, as computed by the tachograph using driver 1 card data. FMB640
FMC640
FMM640
Tachograph data elements
10509 Driver 1 time left until new daily rest period 2 Unsigned 0 65535 - Minutes This parameter shall be the calendar time left until driver 1 shall start a new daily rest period. FMB640
FMC640
FMM640
Tachograph data elements
10510 Driver 1 number of times 9h daily driving time exceeds 1 Unsigned 0 255 - - This parameter shall be the number of times the driver exceeded 9 h daily driving time in the current week.

Value: 0 times to 13 times.

FMB640
FMC640
FMM640
Tachograph data elements
10511 Driver 2 end of last daily rest report 4 Unsigned 0 4294967295 - Timestamp This parameter shall be the end of the last daily rest period of driver 2, as computed by the tachograph using driver 2 card data. How to read Timestamp FMB640
FMC640
FMM640
Tachograph data elements
10512 Driver 2 end of last weekly rest period 4 Unsigned 0 4294967295 - Timestamp This parameter shall be the end of the last weekly rest period of driver 2, as computed by the tachograph

using driver 2 card data. How to read Timestamp

FMB640
FMC640
FMM640
Tachograph data elements
10513 Driver 2 end of second last weekly rest period 4 Unsigned 0 4294967295 - Timestamp This parameter shall be the end of the second last weekly rest period of driver 2, as computed by the tachograph using driver 2 card data. FMB640
FMC640
FMM640
Tachograph data elements
10514 Driver 2 current daily driving time 2 Unsigned 0 65535 - Minutes This parameter shall be the current daily driving time of driver 2, as computed by the tachograph using driver 2 card data.

Value (minutes).

FMB640
FMC640
FMM640
Tachograph data elements
10515 Driver 2 current weekly driving time 2 Unsigned 0 65535 - Minutes This parameter shall be the current weekly driving time of driver 2, as computed by the tachograph using driver 2 card data. FMB640
FMC640
FMM640
Tachograph data elements
10516 Driver 2 time left until new daily rest period 2 Unsigned 0 65535 - Minutes This parameter shall be the calendar time left until driver 2 shall start a new daily rest period. FMB640
FMC640
FMM640
Tachograph data elements
10517 Driver 2 number of times 9h daily driving time exceeds 1 Unsigned 0 255 - - This parameter shall be the number of times the driver exceeded 9 h daily driving time in the current week.

Value: 0 times to 13 times.

FMB640
FMC640
FMM640
Tachograph data elements
10518 Driver 1 Name 36 ASCII 0 36 - - Driver1 Name (FirstByte - Coding ISO/IEC 8859) FMB640
FMC640
FMM640
Tachograph data elements
10519 Driver 1 SurName 36 ASCII 0 36 - - Driver1 SurName (FirstByte - Coding ISO/IEC 8859) FMB640
FMC640
FMM640
Tachograph data elements
10520 Driver 2 Name 36 ASCII 0 36 - - Driver2 Name (FirstByte - Coding ISO/IEC 8859) FMB640
FMC640
FMM640
Tachograph data elements
10521 Driver 2 SurName 36 ASCII 0 36 - - Driver2 SurName (FirstByte - Coding ISO/IEC 8859) FMB640
FMC640
FMM640
Tachograph data elements
10522 Driver 1 Time Left Until New Weekly Rest Period 2 Unsigned 0 65535 - Minutes This parameter shall be the calendar time left until driver 1 shall start a new weekly rest period. FMB640
FMC640
FMM640
Tachograph data elements
10523 Driver 2 Time Left Until New Weekly Rest Period 2 Unsigned 0 65535 - Minutes This parameter shall be the calendar time left until driver 2 shall start a new weekly rest period. FMB640
FMC640
FMM640
Tachograph data elements
10524 Driver 1 Minimum Daily Rest 2 Unsigned 0 65535 - Minutes This parameter shall be the minimum daily rest the driver 1 needs to do to fulfil an on-going or approaching daily rest period FMB640
FMC640
FMM640
Tachograph data elements
10525 Driver 2 Minimum Daily Rest 2 Unsigned 0 65535 - Minutes This parameter shall be the minimum daily rest the driver 2 needs to do to fulfil an on-going or approaching daily rest period FMB640
FMC640
FMM640
Tachograph data elements
10526 Driver 1 Minimum Weekly Rest 2 Unsigned 0 65535 - Minutes This parameter shall be the minimum weekly rest the driver 1 needs to do to fulfil an on-going or approaching weekly rest period. It shall be set to regular or reduced weekly rest period plus compensation hours, if any. FMB640
FMC640
FMM640
Tachograph data elements
10527 Driver 2 Minimum Weekly Rest 2 Unsigned 0 65535 - Minutes This parameter shall be the minimum weekly rest the driver 2 needs to do to fulfil an on-going or approaching weekly rest period. It shall be set to regular or reduced weekly rest period plus compensation hours, if any. FMB640
FMC640
FMM640
Tachograph data elements
10528 Driver 1 Duration Of Next Break Rest 2 Unsigned 0 65535 - Minutes This parameter shall be set to the minimum duration of next break/rest for driver 1 FMB640
FMC640
FMM640
Tachograph data elements
10529 Driver 2 Duration Of Next Break Rest 2 Unsigned 0 65535 - Minutes This parameter shall be set to the minimum duration of next break/rest for driver 2 FMB640
FMC640
FMM640
Tachograph data elements
10530 Driver 1 Remaining Time Until Next Break Or Rest 2 Unsigned 0 65535 - Minutes This parameter shall be set to the remaining time until next rest or break period for driver 1 FMB640
FMC640
FMM640
Tachograph data elements
10531 Driver 2 Remaining Time Until Next Break Or Rest 2 Unsigned 0 65535 - Minutes This parameter shall be set to the remaining time until next rest or break period for driver 2 FMB640
FMC640
FMM640
Tachograph data elements

Mobileye elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
288 ME Sound Type 1 Unsigned 0 7 - -

0 - Silent;
1 - LWD Left;
2 - LWD Right;
3 - HW 1;
4 - TSR;
5 - UFCW;
6 - FCW + PCW;
7 - Peds in danger zone (if enabled).

FMB640
FMC640
FMM640
Mobileye elements
289 ME Pedestrians in Danger Zone 1 Unsigned 0 1 - -

0 - Pedestrian not in danger zone;
1 - Pedestrian in danger zone.

FMB640
FMC640
FMM640
Mobileye elements
290 ME Pedestrians in Forward Collision Warning 1 Unsigned 0 1 - -

0 - No forward collision warning;
1 - Forward collision warning.

FMB640
FMC640
FMM640
Mobileye elements
291 ME Time Indicator 1 Unsigned 0 2 - -

0 - Day is indicated;
1 - Dusk is indicated;
2 - Night is indicated.

FMB640
FMC640
FMM640
Mobileye elements
292 ME Error Valid 1 Unsigned 0 1 - -

0 - Error;
1 - No error.

FMB640
FMC640
FMM640
Mobileye elements
293 ME Error Code 1 Unsigned 0 127 - - Error code FMB640
FMC640
FMM640
Mobileye elements
294 ME Zero Speed 1 Unsigned 0 1 - -

0 - Host vehicle is moving;
1 - Host vehicle is stopped.

FMB640
FMC640
FMM640
Mobileye elements
295 ME Headway Valid 1 Unsigned 0 1 - -

0 - Headway Valid is off;
1 - Headway Valid is on (when CIPV is detected).

FMB640
FMC640
FMM640
Mobileye elements
296 ME Headway Measurement 1 Unsigned 0 9,9 0,1 -

Seconds

FMB640
FMC640
FMM640
Mobileye elements
297 ME LDW Off 1 Unsigned 0 1 - -

0 - LDW are enabled;
1 - LDW are disabled.

FMB640
FMC640
FMM640
Mobileye elements
298 ME Left LDW On 1 Unsigned 0 1 - -

0 - Left LDW are enabled;
1 - Left LDW are disabled.

FMB640
FMC640
FMM640
Mobileye elements
299 ME Right LDW On 1 Unsigned 0 1 - -

0 - Right LDW are enabled;
1 - Right LDW are disabled.

FMB640
FMC640
FMM640
Mobileye elements
300 ME Maintenance 1 Unsigned 0 1 - -

0 - Internal error is not detected;
1 - Internal error is detected.

FMB640
FMC640
FMM640
Mobileye elements
301 ME Fail Safe 1 Unsigned 0 1 - -

0 - Fail Safe indicator is off;
1 - Fail Safe indicator (modes) is on (blur image, saturated image, low sun, partial blockage, partial transparent).

FMB640
FMC640
FMM640
Mobileye elements
302 ME FCW On 1 Unsigned 0 1 - -

0 - FCW are disabled;
1 - FCW are enabled;

FMB640
FMC640
FMM640
Mobileye elements
303 ME TSR Enabled 1 Unsigned 0 1 - -

0 - TSR feature is disabled; 1 - TSR feature is enabled.

FMB640
FMC640
FMM640
Mobileye elements
304 ME Headway Warning Repeat Enabled 1 Unsigned 0 1 - -

0 - Headway Warning Repeat is disabled;
1 - Headway Warning Repeat is enabled.

FMB640
FMC640
FMM640
Mobileye elements
305 ME Headway Warning Level 1 Unsigned 0 2 - -

0 - No CIPV is present;
1 - A CIPV is present with HW > HW Config;
2 - A CIPV is present with HW <= HW Config or HW < 0,6.

FMB640
FMC640
FMM640
Mobileye elements
306 ME TSR Warning Level 1 Unsigned 0 7 - -

0 - Speed <= Road Speed; 1 - Speed > Road Speed + [0-5 km/h];
2 - Speed > Road Speed + [5-10 km/h];
3 - Speed > Road Speed + [10-15 km/h];
4 - Speed > Road Speed + [15-20 km/h];
5 - Speed > Road Speed + [20-25 km/h];
6 - Speed > Road Speed + [25-30 km/h];
7 - Speed > Road Speed + [30-35 km/h] and + 35 km/h;

FMB640
FMC640
FMM640
Mobileye elements
307 ME Tamper Alert 1 Unsigned 0 1 - -

0 - No tamper alert;
1 - Tamper alert.

FMB640
FMC640
FMM640
Mobileye elements
308 ME High Beam 1 Unsigned 0 1 - -

0 - Off;
1 - On.

FMB640
FMC640
FMM640
Mobileye elements
309 ME Low Beam 1 Unsigned 0 1 - -

0 - Off;
1 - On.

FMB640
FMC640
FMM640
Mobileye elements
310 ME Wipers 1 Unsigned 0 1 - -

0 - Off;
1 - On.

FMB640
FMC640
FMM640
Mobileye elements
311 ME Right Signal 1 Unsigned 0 1 - -

0 - Off;
1 - On.

FMB640
FMC640
FMM640
Mobileye elements
312 ME Left Signal 1 Unsigned 0 1 - -

0 - Off;
1 - On.

FMB640
FMC640
FMM640
Mobileye elements
313 ME Brake Signal 1 Unsigned 0 1 - -

0 - Off;
1 - On.

FMB640
FMC640
FMM640
Mobileye elements
314 ME Wipers Available 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Mobileye elements
315 ME Low Beam Available 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Mobileye elements
316 ME High Beam Available 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Mobileye elements
317 ME Speed Available 1 Unsigned 0 1 - - FMB640
FMC640
FMM640
Mobileye elements
318 ME Speed 1 Unsigned 0 255 - km/h FMB640
FMC640
FMM640
Mobileye elements
319 ME TSR 1 8 Unsigned 0 0xffffffffffffffff - - Mobileye sign recognition data FMB640
FMC640
FMM640
Mobileye elements
320 ME TSR 2 8 Unsigned 0 0xffffffffffffffff - - Mobileye sign recognition data FMB640
FMC640
FMM640
Mobileye elements
321 ME TSR 3 8 Unsigned 0 0xffffffffffffffff - - Mobileye sign recognition data FMB640
FMC640
FMM640
Mobileye elements
322 ME TSR 4 8 Unsigned 0 0xffffffffffffffff - - Mobileye sign recognition data FMB640
FMC640
FMM640
Mobileye elements
323 ME TSR 5 8 Unsigned 0 0xffffffffffffffff - - Mobileye sign recognition data FMB640
FMC640
FMM640
Mobileye elements
324 ME TSR 6 8 Unsigned 0 0xffffffffffffffff - - Mobileye sign recognition data FMB640
FMC640
FMM640
Mobileye elements
325 ME TSR 7 8 Unsigned 0 0xffffffffffffffff - - Mobileye sign recognition data FMB640
FMC640
FMM640
Mobileye elements
326 ME TSR VO 8 Unsigned 0 0xffffffffffffffff - - Mobileye vision only sign type data FMB640
FMC640
FMM640
Mobileye elements

ContiPressureCheck TPMS


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
10189 Total Tires 1 Unsiged 0 0xFF - TPMS Total Tires FMB640
FMC640
FMM640
TPMS
10190 Total Axles 1 Unsiged 0 0xFF - FMB640
FMC640
FMM640
TPMS
10191 Graphical Position 8 Unsiged 0 0xFFFFFFFFFFFFFFFF - FMB640
FMC640
FMM640
TPMS
10192 Tire 1 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10193 Tire 2 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10194 Tire 3 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10195 Tire 4 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10196 Tire 5 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10197 Tire 6 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10198 Tire 7 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10199 Tire 8 pressure 1 HEX 0 0xFF - kPan FMB640
FMC640
FMM640
TPMS
10200 Tire 9 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10201 Tire 10 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10202 Tire 11 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10203 Tire 12 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10204 Tire 13 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10205 Tire 14 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10206 Tire 15 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10207 Tire 16 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10208 Tire 17 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10209 Tire 18 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10210 Tire 19 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10211 Tire 20 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10212 Tire 21 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10213 Tire 22 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10214 Tire 23 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10215 Tire 24 pressure 1 HEX 0 0xFF - kPa FMB640
FMC640
FMM640
TPMS
10360 Tire 1 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10361 Tire 1 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10362 Tire 2 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10363 Tire 2 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10364 Tire 3 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10365 Tire 3 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10366 Tire 4 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10367 Tire 4 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10368 Tire 5 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10369 Tire 5 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10370 Tire 6 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10371 Tire 6 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10372 Tire 7 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10373 Tire 7 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10374 Tire 8 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10375 Tire 8 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10376 Tire 9 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10377 Tire 9 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10378 Tire 10 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10379 Tire 10 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10380 Tire 11 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10381 Tire 11 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10382 Tire 12 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10383 Tire 12 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10384 Tire 13 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10385 Tire 13 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10386 Tire 14 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10387 Tire 14 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10388 Tire 15 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10389 Tire 15 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10390 Tire 16 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10391 Tire 16 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10392 Tire 17 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10393 Tire 17 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10394 Tire 18 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10395 Tire 18 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10396 Tire 19 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10397 Tire 19 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10398 Tire 20 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10399 Tire 20 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10400 Tire 21 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10401 Tire 21 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10402 Tire 22 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10403 Tire 22 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10404 Tire 23 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10405 Tire 23 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS
10406 Tire 24 Temperature 1 HEX 0 0xFF - °C FMB640
FMC640
FMM640
TPMS
10407 Tire 24 Warning 1 HEX 0 0xFF - FMB640
FMC640
FMM640
TPMS

Reefer IO


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
10056 Zone 2 Return Air Sensor 1 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10057 Zone 2 Supply Air Sensor 1 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10058 Zone 2 Set Temperature 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10059 Zone 2 Evaporator temperature 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10060 Zone 2 Return Air sensor 2 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10061 Zone 2 Supply Air sensor 2 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10062 Power mode 1 Unsigned 0 7 - - OLD: Zone 2 Operating Mode FMB640
FMC640
FMM640
Reefer IO
10063 Zone 3 Compartment state 1 Unsigned 0 15 - - OLD: Alarm Type FMB640
FMC640
FMM640
Reefer IO
10064 Zone 3 Compartment mode 1 Unsigned 0 255 - - OLD: Alarm Code FMB640
FMC640
FMM640
Reefer IO
10065 Zone 3 Return Air sensor 1 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10066 Zone 3 Supply Air sensor 1 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10067 Zone 3 Set Temperature 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10068 Zone 3 Evaporator temperature 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10069 Zone 3 Return Air sensor 2 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10070 Zone 3 Supply Air sensor. 2 2 Signed -32768 32767 0,1 °C Degrees, °C FMB640
FMC640
FMM640
Reefer IO
10071 Speed mode 1 Unsigned 0 7 - - OLD: Zone 3 Operating Mode FMB640
FMC640
FMM640
Reefer IO
10350 Ambient Air Temperature 2 Signed -18382 18026 0,1 °C Ambient Air Temperature in celsius degrees multiplied by 10 FMB640
FMC640
FMM640
Reefer IO
10351 Compressor Coolant Temperature 2 Signed -18382 18026 0,1 °C Compressor Coolant Temperature in celsius degrees multiplied by 10 FMB640
FMC640
FMM640
Reefer IO
10353 Compressor Config 2 Unsigned 0 20000 - RPM FMB640
FMC640
FMM640
Reefer IO
10356 Installation Serial 8 Unsigned 0 0xffffffffffffffff - String Fridge Installation Serial String FMB640
FMC640
FMM640
Reefer IO
10464 Digital Sensor 1 1 Unsigned 0 0xff - - Logic 0/1 FMB640
FMC640
FMM640
Reefer IO
10465 Digital Sensor 2 1 Unsigned 0 0xff - - Logic 0/1 FMB640
FMC640
FMM640
Reefer IO
10466 Digital Sensor 3 1 Unsigned 0 0xff - - Logic 0/1 FMB640
FMC640
FMM640
Reefer IO
10467 Digital Sensor 4 1 Unsigned 0 0xff - - Logic 0/1 FMB640
FMC640
FMM640
Reefer IO
10468 Analog Input 1 2 Unsigned 0 0xffff - V Analog Input 1 FMB640
FMC640
FMM640
Reefer IO
10469 Analog Input 2 2 Unsigned 0 0xffff - V Analog Input 2 FMB640
FMC640
FMM640
Reefer IO
10470 Analog Input 3 2 Unsigned 0 0xffff - V Analog Input 3 FMB640
FMC640
FMM640
Reefer IO
10472 Manufacturer ID 1 Unsigned 0 0xff - - Fridge ID FMB640
FMC640
FMM640
Reefer IO
10473 Battery State Flags 1 Unsigned 0 0xff - enum

(bit field)

Battery Flags

bit0-Awailable bit1-Error bit2-Alarm bit3-DigitalSensor

FMB640
FMC640
FMM640
Reefer IO
10474 Fuel state flags 1 Unsigned 0 0xff - enum

(bit field)

Fuel flags

bit0-Awailable bit1-Error bit2-Alarm bit3-DigitalSensor

FMB640
FMC640
FMM640
Reefer IO
10475 Maintenance 1 Hours 4 Unsigned 0 0xffffffff - h Maintenance 1 Hours FMB640
FMC640
FMM640
Reefer IO
10476 Maintenance 2 Hours 4 Unsigned 0 0xffffffff - h Maintenance 2 Hours FMB640
FMC640
FMM640
Reefer IO
10477 Maintenance 3 Hours 4 Unsigned 0 0xffffffff - h Maintenance 3 Hours FMB640
FMC640
FMM640
Reefer IO
10478 Maintenance 4 Hours 4 Unsigned 0 0xffffffff - h Maintenance 4 Hours FMB640
FMC640
FMM640
Freezer IO Elements


10479 Maintenance 5 Hours 4 Unsigned 0 0xffffffff - h Maintenance 5 Hours FMB640
FMC640
FMM640
Reefer IO
10480 Run Mode 1 Unsigned 0 0xff - - Run Mode

0:StartStop (SS) 1:Continious 2:CycleCentry (CS) 7:Unknown/Now awailable

FMB640
FMC640
FMM640
Reefer IO
10639 Error Codes 16 HEX 0 16 - - Fridge error codes array FMB640
FMC640
FMM640
Reefer IO
10644 Temperature Probe 1 2 Signed -32768 32767 - - Temperature Probe 1 FMB640
FMC640
FMM640
Reefer IO
10645 Temperature Probe 2 2 Signed -32768 32767 - - Temperature Probe 2 FMB640
FMC640
FMM640
Reefer IO
10646 Temperature Probe 3 2 Signed -32768 32767 - - Temperature Probe 3 FMB640
FMC640
FMM640
Reefer IO
10647 Temperature Probe 4 2 Signed -32768 32767 - - Temperature Probe 4 FMB640
FMC640
FMM640
Reefer IO
10648 Temperature Probe 5 2 Signed -32768 32767 - - Temperature Probe 5 FMB640
FMC640
FMM640
Reefer IO
10649 Temperature Probe 6 2 Signed -32768 32767 - - Temperature Probe 6 FMB640
FMC640
FMM640
Reefer IO

TK Euroscan IO


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
10683 Temperature 1 2 Signed -32768 32767 0.1 °C Temperature 1 FMB640
FMC640
FMM640
Euroscan IO
10684 Temperature 2 2 Signed -32768 32767 0.1 °C Temperature 2 FMB640
FMC640
FMM640
Euroscan IO
10685 Temperature 3 2 Signed -32768 32767 0.1 °C Temperature 3 FMB640
FMC640
FMM640
Euroscan IO
10686 Temperature 4 2 Signed -32768 32767 0.1 °C Temperature 4 FMB640
FMC640
FMM640
Euroscan IO

TK Touchprint IO


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
10695 Input 1 2 Signed -32768 32767 0.1 °C Input 1 FMB640
FMC640
FMM640
TK Touchprint IO
10696 Input 2 2 Signed -32768 32767 0.1 °C Input 2 FMB640
FMC640
FMM640
TK Touchprint IO
10697 Input 3 2 Signed -32768 32767 0.1 °C Input 3 FMB640
FMC640
FMM640
TK Touchprint IO
10698 Input 4 2 Signed -32768 32767 0.1 °C Input 4 FMB640
FMC640
FMM640
TK Touchprint IO
10699 Input 5 2 Signed -32768 32767 0.1 °C Input 5 FMB640
FMC640
FMM640
TK Touchprint IO
10700 Input 6 2 Signed -32768 32767 0.1 °C Input 6 FMB640
FMC640
FMM640
TK Touchprint IO
10701 Setpoint 1 2 Signed -32768 32767 0.1 °C Setpoint 1 FMB640
FMC640
FMM640
TK Touchprint IO
10702 Setpoint 2 2 Signed -32768 32767 0.1 °C Setpoint 2 FMB640
FMC640
FMM640
TK Touchprint IO
10703 Setpoint 3 2 Signed -32768 32767 0.1 °C Setpoint 3 FMB640
FMC640
FMM640
TK Touchprint IO