CAN-CONTROL

From Wiki Knowledge Base | Teltonika GPS
Revision as of 16:24, 30 November 2018 by Mantas.gadliauskas (talk | contribs) (Created page with "right|250px CAN-CONTROL is designed to acquire [https://en.wikipedia.org/wiki/CAN_bus CAN Bus] data and remotely control: * Light vehicles (includ...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > CAN Trackers & Adapters > CAN-CONTROL
CANCONTROL-new1.png

CAN-CONTROL is designed to acquire CAN Bus data and remotely control:

  • Light vehicles (including electric cars)

Teltonika delivers solution for car sharing and mobility applications. CAN-CONTROL allows to read essential CAN Bus data from the vehicle and remotely control doors (lock/ unlock) and windows.

Supported vehicles features*

Control features

  1. Turn signal control
  2. Comfort closure (Central locking, Windows, Power folding mirrors)
  3. All doors lock
  4. All doors unlock
  5. Trunk release
  6. Factory alarm management
  7. Control central lock when ignition is on

CAN bus data

  1. Total fuel consumption
  2. Fuel level (Dashboard) (Fuel level - percent or Fuel level - Liters)
  3. Vehicle mileage (Vehicle mileage from dashboard or Vehicle mileage counted (from adapter installation))
  4. Door status (Front left door, Front right door, Rear right door, Rear left door, Trunk cover, Engine cover (hood))
  5. Engine speed (RPM)
  6. Oil pressure / level
  7. Engine temperature
  8. Vehicle speed
  9. Accelerator pedal position
  10. CNG level
  11. Total CNG consumption
  12. Engine is working on CNG
  13. AND MORE...

Electric vehicles CAN bus data

  1. Charging cable connected
  2. Charging the battery
  3. Battery level
  4. Vehicle range on battery

* Number of features depends on vehicle model, year and equipment.

Technical features

PARAMETER VALUE
Minimum Typical Maximum Unit
Supply Voltage
Supply Voltage (Recommended Operating Conditions) +9 +12 +16 V
Current Consumption
Working Mode (with 12V) 24 mA
Sleep Mode (with 12V) 1 mA
Operating Temperature
Operating Temperature -40 +85 °C