TSM232

Revision as of 16:45, 5 December 2019 by Sandra.Gasyte (talk | contribs) (Created page with "right|250px Teltonika TSM232 is Iridium SATELLITE terminal with a backup battery. The full solution combines Teltonika TSM232 with Teltoni...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > Accessories > TSM232
TSM232 2019-11-20.1(2).png

Teltonika TSM232 is Iridium SATELLITE terminal with a backup battery. The full solution combines Teltonika TSM232 with Teltonika FM63XY, FMB630 or FMB640 connected via RS232. This solution allows transferring data to a server via the Iridium satellite network when other terrestrial networks are unavailable. High capacity internal Ni-MH battery ensures long autonomous working hours when the main power source is disconnected. Such a solution meets the demand for high-security logistic, marine transport, construction & mining transport, oil/gas industry, public safety, government/defense and more.

Basic characteristics

Features:

  • Data transferring via Iridium satellite network when GSM network is unavailable
  • Smart RSS232 communication algorithm
  • One FM63XY/FMB630/FMB640 message size forwarded to TSM232 is only 14bytes
  • Message contains: Time/Coordinates/Speed/DIN1-4/DOUT1-2/Event ID
  • Data sending can be initiated by periodic time interval or by panic priority event Specification:
  • Iridium satellite transceiver 9603
  • CPU STM32F103VDH6

Interface:

  • RS232
  • External Iridium antenna
  • Internal Ni-MH backup rechargeable battery 7.2V 400mAh
  • External power input DC 10-30V
  • USB
  • Digital input
  • Analog input
  • Digital output

Technical Information about internal battery

Internal backup battery Battery voltage

(V)

Nominal capacity (mAh) Power(Wh)(mAh) Charging temperature (°C) Standard discharge temperature (°C)
Ni-MH Prismatic Battery pack 7,2 ~7,5 400 2,95 – 3,07 0 – 40 Ambient Temperature: 20±5


  CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
  Battery should not be disposed of into general household waste.
Bring damaged or worn-out batteries to your local recycling center or dispose them into a battery recycle bin commonly found in supermarkets.

Technical characteristics

PARAMETER VALUE
Minimum Typical Maximum Unit
Supply Voltage
Supply Voltage (Recommended Operating Conditions) +10 +30 V
Digital Output (Open Drain grade)
Drain current (Digital Output OFF) 120 μA
Drain current (Digital Output ON, Recommended Operating Conditions) 300 mA
Static Drain-Source resistance (Digital Output ON) 120
Digital Input
Input resistance (DIN1) 59,9
Input Voltage (Recommended Operating Conditions) 0 60 V
Input Voltage threshold (DIN1) 7,5 7,7 8 V
Analog Input
Input Voltage (Recommended Operating Conditions), Range1 0 10 V
Input resistance, Range1 120

Additional specifications:

  • Input current/power specification - 250mA RMS max.
  • Use 3A, 125V external fuse.
  • Internal fuse specifications: Quick-acting; Rated current: 3A; Rated Breaking Capacity: 50A @ AC/DC 125V.
  • The device uses SELV limited power source. Nominal voltage is 12 V DC. The allowed range of voltage is 10 V...30 V DC. 

TSM232 Current consumption from battery

Mode/Voltage battery 12 V 7.2 V
Disconnected RS232 23.575 37.736
Connected RS232 (0 min send) with SIM (sleep) 8.246 14.994
Connected RS232 (1 min send) 19.808 30.473