Product change notifications (PCN) is the way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, firmware changes, changes to package contents, etc.
This page stores information regarding changes to the FMB640 tracking device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).
We would like to inform you about the base firmware update for FMB640 starting in late-August 2022. New production firmware version will be 01.02.22.Rev.02.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2022.05.24: GNSS antenna changes
We would like to inform you about the GNSS antenna changes for FMB640 starting September 2022.
Change description
Change type
Mechanical part changes
Detailed description
Old version:
Dimensions - 46x44x13 mm
Center frequency - 1575.42 MHz, 1602 MHz
Bandwidth - 35 MHz
VSWR on bandwidth - <1.9
GAIN - 3 dB
LNA minimum gain - 26.5 dB
LNA maximum gain - 29.5 dB
Consumption - 9 mA
New version:
Dimensions - 45.2x35.8x15.1 mm
Center frequency - 1575.42 MHz, 1602 MHz
Bandwidth - 10 MHz
VSWR on bandwidth - <1.5
GAIN - 2 dB
LNA minimum gain - 26 dB
LNA maximum gain - 30 dB
Consumption - 11 mA
Change reasons
Reaction to antenna market volatility.
Product release date
September 2022
Affected products
Model
Affected order codes
Order code changes
FMB640
FMB640*******order codes
No changes
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
No implementation plan needed
2021.08.16: SMA soldering changes
We would like to inform you that Antenna connectors (SMA SMD type) in FMB640 devices will be soldered from both sides of PCB starting from mid-August 2021.
Change description
Change type
Internal
Detailed description
Old version:
New version:
Change reasons/Description
In order to increase the structural rigidity and unify the manufacturing process of Teltonika IoT Group devices, SMA connector will be soldered on the top side of PCB (same as before) and on the bottom side of PCB (performed additionally).
Product release date
Second half of August 2021
Affected products
Model
Affected order codes
Order code changes
FMB640
FMB640*******
SMA soldering changes
Change impact
Risk assessment
Due to THT assembly process, some devices might have an excess amount of soldering on the SMA connector. This does not affect GSM/GNSS antenna characteristics and does not interfere with device case assembly, therefore, device functionality remains unchanged.
Suggested implementation plan
No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2021.08.03: Upgraded casing
We would like to inform you, that FMB640 device case will be updated in the factory by the end of August 2021.
Change description
Change type
External/visual
Detailed description
Old version:
New version:
Change reasons/Description
Changes are made only in internal part of the case:. 1. Additional ribs added to battery guard walls 2. A third section of the wall added Changes are made to ensure easier and more sufficient manufacturing process of the case itself - change has no effect on device functioning.
Product release date
End of August 2021
Affected products
Model
Affected order codes
Order code changes
FMB640
FMB640*******
New casing
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2021.05.26: Base firmware update
We would like to inform you about the base firmware update for FMB640 starting from May 26 2021. New production firmware version will be 01.00.13.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2021.05.18: New material and design changes on the device casing
We would like to inform you, that FMB640 device case will be updated in the factory on first half of June 2021.
Change description
Change type
External/visual
Detailed description
Old version:
New version:
Change reasons/Description
1. New material unifies the device design across all platforms. 2. LED indentations improve Dust/Water resistance - LEDs are visible through thin layer of material. 3. New battery guard ensures battery placement during device transportation and usage.
Product release date
First half of June 2021
Affected products
Model
Affected order codes
Order code changes
FMB640
FMB640*******
New casing
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
Small indentation on top of USB socket will allow you to identify the cases quicker
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2021.03.01: Top Laser Printing Changes
We would like to inform you, that laser printing of the FMB640 device was updated in the factory on March 2021.
Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2020.11.24: GNSS antenna changes
We would like to inform you about the GNSS antenna changes for FMB640 starting from late December 2020 - early January 2021.
Change description
Change type
Mechanical part changes
Detailed description
Old version:
Dimensions - 45.2x35.8x15.1 mm
Center frequency - 1575.42 MHz, 1600 MHz
Bandwidth - 10 MHz
VSWR on bandwidth - <1.5
GAIN - 3 dB
LNA minimum gain - 26 dB
LNA maximum gain - 30 dB
Consumption - 11 mA
New version:
Dimensions - 46x44x13 mm
Center frequency - 1575.42 MHz, 1602 MHz Bandwidth - 35 MHz VSWR on bandwidth - <1.9
GAIN - 3 dB
LNA minimum gain - 26.5 dB
LNA maximum gain - 29.5 dB
Consumption - 9 mA
Change reasons
According to technical comparison new antenna is better by next parameters: center frequency, bandwidth, consumption. Other parameters are the same. Moreover, the new antenna is thinner, which gives the opportunity to mount it, where it was not possible before and makes installation easier.
Product release date
Late December 2020 - Early January 2021
Affected products
Model
Affected order codes
Order code changes
FMB640
FMB640*******order codes
No changes
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
No implementation plan needed
2020.10.26: Base firmware update
We would like to inform you about the base firmware update for FMB640 starting from October 26th, 2020. New production firmware version will be 01.00.05.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager
2019.10.18: New FMB640 case design / Top Marking Changes
Change description
External/visual
Packaging
Detailed description
New case design.
Device marking changed from tampography to laser printing. Information provided on module will remain the same.
Old version:
Dimensions: 104.5 (L) x 70.9 (W) x 31.5 (H) mm
New version:
Dimensions: 104.5 (L) x 71.6 (W) x 27.3 (H) mm
Change reasons
New case design as other FMB series devices to fit corporate design and make it more ergonomic, smaller in dimensions.
Tampography to laser printing changed, to improve manufacturing speed, efficiency and reliability.
Product release date
Planned date: 2020 First part of January
Affected products
Model
Affected order codes
Order code changes
FMB640
FMB640******
No changes
You can already order a sample with a new case and laser printing by order code: FMB6403BFE01. (Max quantity of samples per order 2pcs )
Change impact
Risk assessment
Risk assessment for devices management required
Suggested implementation plan
No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.
2019.07.22: new no brand Eco friendly boxes
Effective from 1Q of the year 2020, FMB640 trackers with no brand packaging will be shipped with a new no brand eco-friendly box.
Change description
Change type
Packaging
Detailed description
Improved and more environmentally friendly packaging box
Old single packaging version:
Dimensions: 177 (W) x 145 (D) x 64 (H)
New single packaging version:
Dimensions: 173 (W) x 148 (D) x 71 (H)
Change reasons
The new box is better for the environment
Product release date
Devices with new packaging will be released in manufacturing from 1Q of year 2020 with 2 months of transition period. Over this period devices with white packaging can be delivered as well as devices with the new eco boxes.
Affected products
Model
Affected order codes
Order code changes
FMB640, FM6300.
FMB640******, FM6300******.
No changes
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
Due to the new look of boxes we strongly recommend to update your marketing materials. Because of the new color of the packaging box, if necessary, update your branding materials (stickers, logo layouts).
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2019.06.14: Device module information display changes
We would like to inform you, that the information display on device module TM2500 will be updated in the factory from July 2019.
Change description
Change type
External/visual
Detailed description
Information display on TM2500 module will change from sticker to laser print. Information provided on module will remain the same.
Old Version:
New Version:
Change reasons
Laser printing will increase reliability, speed, and will reduce paper waste.
Product release date
Devices with new module marking will be released in manufacturing from July with 2 months of transition period. Over this period devices with sticker can be delivered as well as devices with laser print.
The change will not affect clients. All the module characteristics will remain unchanged. The only sticker on module will be changed to laser print. The displayed information will remain the same.
Suggested implementation plan.
Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in the customs clearance process.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.
2019.04.10: IMEI/SN display on device Changes
We would like to inform you, that IMEI/SN info display on the FMB640 device will be updated in the factory from June 2019.
Change description
Change type
External/visual
Detailed description
IMEI/SN info on device display change from barcode to QR
Old Version:
New Version:
This change will not affect device packing and logistic lists. It will remain as barcode.
Change reasons
QR format will increase reliability and minimize error rate, because of the error correction feature and improved reading in low contrast.
Product release date
Devices with new QR Code format will be released in manufacturing from June with 2 months of transition period. Over this period devices with barcode can be delivered as well as devices with QR code.
Affected products
Model
Affected order codes
Order code changes
FMB640
FMB640******
No changes
Change impact
Risk assessment
Risk assessment for devices management required
Suggested implementation plan
Due to changes in device information display we strongly recommend to check, and prepare your tools to read QR codes.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here
2019.03.04: Top Tampography Changes
We would like to inform you, that tampography of the FMB640 device was updated in the factory on the 4th of March.
Change description
Change type
External/visual
Detailed description
Top tampography design changed
Old Version:
New Version:
Change reasons
1. Updated Teltonika address to Saltoniskiu st. 9B-1 2. Added WEEE label. (WEEE - Waste from Electrical and Electronic Equipment)
Product release date
Updated tampography will be used from the time when the stock will be sold all leftovers.
Affected products
Model
Affected order codes
Order code changes
FMB640
FMB640*******
No changes
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.
2019.01.18: New eco friendly box
Effective January 2019, week 4, FMB640 trackers will be packed with a new eco-friendly box.
Change description
Change type
Packaging
Detailed description
Improved and more environmentally friendly packaging box
Old version:
New version:
Change reasons
The new box is better for the environment
Product release date
January 2019, week 4
Affected products
Model
Affected order codes
Order code changes
FMB640
FMB640*******
No changes
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.