Inateck BCST-70 Communication Protocol

Revision as of 10:34, 2 May 2023 by Patrick.sangalang (talk | contribs) (Protected "Inateck BCST-70 Communication Protocol" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > Accessories > Inateck BCST-70 Barcode Scanner > Inateck BCST-70 Communication Protocol

Raw Data

Unparsed received data in hexadecimal stream

00000000000000A28E0100000181A39E2F700000000000000000000000000000000001080007000200EF01010702000400B5000000B6000000423DD900430E010000000000010108000E 3132333031363030303037303939010000E25B

AVL Data Packet Part HEX Code Part
Zero Bytes 00 00 00 00
Data Field Length 00 00 00 A2
Codec ID 8E (Codec 8 Extended)
Number of Data 1 (Number of Total Records) 01
Timestamp 00 00 01 81 A3 9E 2F 70 (Monday, June 27, 2022 4:30:46 PM GMT+00:00)
Priority 00
Longitude 0F 0E 53 AE
Latitude 20 9A B8 6A
Altitude 00 7F
Angle 00 11
Satellites 0D
Speed 00 00
Event IO ID 01 08 (Barcode ID)
N of Total ID 00 07
N1 of One Byte IO 00 02
1’st IO ID 00 EF (AVL ID: 239, Name: Ignition)
1’st IO Value 01
2’nd IO ID 01 07 (AVL ID: 263, Name: BT Status)
2’nd IO Value 02
N2 of Two Byte IO 00 04
1’st IO ID 00 B5 (AVL ID: 181, Name: GNSS PDOP)
1’st IO Value 00 0A
2’nd IO ID 00 B6 (AVL ID: 182, Name: GNSS HDOP)
2’nd IO Value 00 06
3’rd IO ID 42 (AVL ID: 66, Name: External Voltage)
3’rd IO Value 3F C9
4'th IO ID 43 (AVL ID: 67, Battery Voltage)
4'th IO Value 0E 01
N4 of Four Byte IO 00 00
N8 of Eight Byte IO 00 00
NX of X Byte IO 00 01
1’st IO ID 01 08 (AVL ID: 264, Name: Barcode ID)
1’st IO Value 31 32 33 30 31 36 30 30 30 30 37 30 39 39
Number of Data 2 (Number of Total Records) 01
CRC-16 00 00 E2 5B

Parsing Information

Sensor information comes from the AVL IDs mentioned below.

Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
263 BT Status 1 Unsigned 0 4 - - 0 - BT is disabled
1 - BT Enabled, not device connected
2 - Device connected, BTv3 Only
3 - Device connected, BLE only
4 - Device connected, BLE + BT
Permanent I/O elements
264 Barcode ID Variable ASCII 0 32 - - Barcode ID Permanent I/O elements


Parsing AVL ID 264 data


Example:

Hex Data from ID 264: 31 32 33 30 31 36 30 30 30 30 37 30 39 39

Eliminate 3 from the header would make the data look likes this

Barcode ID: 12301600007099


Actual Barcode Scanned

 

Demonstration in Flespi Platform


Flespi: Open Flespi application → Select Telematics Hub→ Select Devices → Select the FM device → Select Barcode.id → to access all the information.