'''Functionality:'''
+
'''Futures:'''
   −
* Unpaired reader (state after default reset) is waiting for button only
+
* Mifare® Classic, Desfire card supports
* Reader scans for RFID card or button press all time after it is paired
+
* Bluetooth low energy module
* In the case previously mentioned events occur, the reader sends an advertising packet for Ta time in period Tb. Defaults: Ta=50sec, Tb=100ms
+
* Operating frequency - 13,56MHz
* While NBL-2 is advertising the green led is flashing slowly. The reader stops blinking and advertising after disconnection.
+
* Built in two LED indicators
* Depending on the configuration, read card ID can be present on the advertising packet or/and on characteristic
+
* Built in two buttons
* Reader closes the connection and goes into low power 50 seconds after the last data exchange.
+
* UID and card DATA available
* Reader can be on/off by long button press
+
* Configure via BL link
* Reader performs sensor measurement in a period that is configurable
+
* Firmware update via Bluetooth
* Button reacts immediately
  −
* Sensors configuration is set by GATT services.
  −
* Detecting the start and stop of the vehicle. This mode is active immediately after turning on the device.<br />
   
==Product Specification==
 
==Product Specification==
 
{| class="wikitable"
 
{| class="wikitable"
|Operating frequency
  −
|13,56MHz
  −
|-
  −
|Supported standards
  −
|MIFARE® Classic
  −
MIFARE® DESFire
  −
|-
  −
|Interface
  −
|Bluetooth
   
|-
 
|-
 
|Supply voltage
 
|Supply voltage
Line 48: Line 36:  
|Size (mm)
 
|Size (mm)
 
|58 x 99 x 19
 
|58 x 99 x 19
 +
|-
 +
|Weight
 +
|43.78 g
 
|-
 
|-
 
|Type
 
|Type
Line 53: Line 44:  
|}
 
|}
   −
==NBL-2 configuration==
+
==NBL-2 updating==
    +
First, you have to make sure that NBL-2 firmware version is updated to 1.3.
    +
If the firmware version is lower than 1.3, it is necessary to update the device.
 
'''1.    Updating NBL-2'''
 
'''1.    Updating NBL-2'''
   −
First, you have to make sure that NBL-2 firmware version is updated to 1.3. Go to NBL Tools application -> Device -> Characteristic -> Device Information Service -> Firmware Revision String.
+
Go to NBL Tools application -> Device -> Characteristic -> Device Information Service -> Firmware Revision String.
    
[[File:NBL_conf1.jpg.jpg|alt=|frameless|520x520px]]  [[File:NBL_conf2.jpg.jpg|alt=|border|frameless|520x520px]]  [[File:NBL_conf3.jpg.jpg|alt=|frameless|519x519px]]
 