− | * Unpaired reader (state after default reset) is waiting for button only | + | * Mifare® Classic, Desfire card supports |
− | * Reader scans for RFID card or button press all time after it is paired
| + | * Bluetooth low energy module |
− | * In the case previously mentioned events occur, the reader sends an advertising packet for Ta time in period Tb. Defaults: Ta=50sec, Tb=100ms | + | * Operating frequency - 13,56MHz |
− | * While NBL-2 is advertising the green led is flashing slowly. The reader stops blinking and advertising after disconnection. | + | * Built in two LED indicators |
− | * Depending on the configuration, read card ID can be present on the advertising packet or/and on characteristic
| + | * Built in two buttons |
− | * Reader closes the connection and goes into low power 50 seconds after the last data exchange. | + | * UID and card DATA available |
− | * Reader can be on/off by long button press
| + | * Configure via BL link |
− | * Reader performs sensor measurement in a period that is configurable | + | * Firmware update via Bluetooth |
− | * Button reacts immediately | |
− | * Sensors configuration is set by GATT services. | |
− | * Detecting the start and stop of the vehicle. This mode is active immediately after turning on the device.<br /> | |
| ==Product Specification== | | ==Product Specification== |
| {| class="wikitable" | | {| class="wikitable" |
− | |Operating frequency
| |
− | |13,56MHz
| |
− | |-
| |
− | |Supported standards
| |
− | |MIFARE® Classic
| |
− | MIFARE® DESFire
| |
− | |-
| |
− | |Interface
| |
− | |Bluetooth
| |
| |- | | |- |
| |Supply voltage | | |Supply voltage |
Line 48: |
Line 36: |
| |Size (mm) | | |Size (mm) |
| |58 x 99 x 19 | | |58 x 99 x 19 |
| + | |- |
| + | |Weight |
| + | |43.78 g |
| |- | | |- |
| |Type | | |Type |
Line 53: |
Line 44: |
| |} | | |} |
| | | |
− | ==NBL-2 configuration== | + | ==NBL-2 updating== |
| | | |
| + | First, you have to make sure that NBL-2 firmware version is updated to 1.3. |
| | | |
| + | If the firmware version is lower than 1.3, it is necessary to update the device. |
| '''1. Updating NBL-2''' | | '''1. Updating NBL-2''' |
| | | |
− | First, you have to make sure that NBL-2 firmware version is updated to 1.3. Go to NBL Tools application -> Device -> Characteristic -> Device Information Service -> Firmware Revision String.
| + | Go to NBL Tools application -> Device -> Characteristic -> Device Information Service -> Firmware Revision String. |
| | | |
| [[File:NBL_conf1.jpg.jpg|alt=|frameless|520x520px]] [[File:NBL_conf2.jpg.jpg|alt=|border|frameless|520x520px]] [[File:NBL_conf3.jpg.jpg|alt=|frameless|519x519px]] | | [[File:NBL_conf1.jpg.jpg|alt=|frameless|520x520px]] [[File:NBL_conf2.jpg.jpg|alt=|border|frameless|520x520px]] [[File:NBL_conf3.jpg.jpg|alt=|frameless|519x519px]] |