TFT100 Features settings
Eco/Green Driving
When vehicle parameters exceed the values of Max Acceleration, Max Braking or Max Cornering parameters, the scenario is activated: a record is generated and digital output status is changed to 1 when configured. You can configure all three parameters in m/s2 units. Scenario is activated until current Acceleration, Braking or Cornering value decreases below the set parameter value.
Data from accelerometer/GPS are continuously monitored and processed and are used to decide whether a harsh event has occurred. If either of three cases is satisfied, an event is generated and a record is saved and sent to the server TFT100 must be properly configured in order to send the record). Event value is multiplied by 100 before sending/saving record to get more precision when displaying data.
|
Auto calibration
The auto-calibration process is following:
- The vehicle is stopped.
- There is a straight road ahead.
- Send SMS "auto_calibrate:set" to the TFT100 device.
- Accelerate to >7 km/h for 5 sec.
- TFT100 will send a response when calibration is completed successfully.
Calibration is saved to internal flash memory, which means it will stay after a reset. To check auto-calibration status send a following short text message to the TFT100 device: "auto_calibrate:get".
Over Speeding
When vehicle speed exceeds configured maximum speed value the scenario is activated, an event record is generated and digital output status is changed to 1 when configured.
|
Jamming
When GSM signal jamming is detected the scenario is activated, an event record is generated and digital output status is changed to 1 when configured once Jamming timeout runs out. If jamming ends during timeout countdown no event will be generated| and output will not be controlled.
Eventual Records parameter can be configured: when it is disabled scenario status value will appear in each AVL record, otherwise it will be appended only to eventual records.
- Output Control - Scenario will activate the selected output.
None
- If event happens, it will not affect DOUT state.DOUT1
- If event happens, Digital output 1 will be activated.DOUT2
- If event happens, Digital output 2 will be activated.
Digital output 1 or digital output 2 can be activated for a period of time to warn the driver. Output on-time is configured separately for each feature case. For more information please refer to DOUT controls.
DOUT Control Via Call
Scenario is activated and digital output is ON when call is received from a number which is on the authorized numbers list.
|
Immobilizer
If DOUT Control is disabled, scenario will only generate events without digital output activation. If DOUT Control is enabled DOUT1/DOUT2 turns ON if ignition turns ON (Ignition Source is configured to 1). After any iButton ID is attached, DOUT1/DOUT2 turns OFF. After iButton identification configured Ignition Source can be turned OFF (Ignition Source is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated. If iButton List Check parameter is enabled, authorization will be successful only if the attached iButton is specified in iButton list.
DETAILED IMMOBILIZER WIRING for testing can be found here |
iButton Read Notification
This functionality allows user to see when iButton is read. DOUT1/DOUT2 turns on for a configured duration and after DOUT ON duration ends DOUT1/DOUT2 does not turn on even if iButton is left attached.
|
FallDown
This feature allows to detect if the device has fallen on one of the sides after the base device position was saved via autocalibration.
|
Last Known Position
This feature adds low priority record If the last good coordinate at the time the record is created is older than 60 seconds, then the new high priority record DOUT Control Via Ignition
Ignition On Counter
|