| VERSION | RELEASE DATE | CONFIGURATOR CHANGES | FIRMWARE CHANGES |
|---|---|---|---|
Firmware version: 55.00.16.Rev.571BlueNRG version: 10.0.3.Rev.00 for TAT100 HW ver.: 31 |
2025.02.11 |
* None |
* Fixed an issue where the device got stuck with an open link and failed to go to sleep in an edge case. * Ported GPRS Authentication for Quectel modems. * Minor improvements on the modem and BlueNRG firmware. |
| VERSION | RELEASE DATE | CONFIGURATOR CHANGES | FIRMWARE CHANGES |
|---|---|---|---|
Firmware version: 55.00.16.Rev.569BlueNRG version: 10.0.3.Rev.00 for TAT100 HW ver.: 31 |
2024.08.19 |
* Added an option to configure TLS functionality. * Added an option to configure SMS record sending. * Added an option to configure MQTT Azure and AWS support. * Added an option to configure I am alive feature. |
* Added TLS functionality feature. * Added SMS record sending feature. * Added MQTT Azure and AWS support. * Added I am alive feature. * Fixed X, Y and Z IO elements not being included with First Power On record. * Extended On Stop and On Move periodic timers to maximum value of 7 days. * Improvements to Static Navigation logic in no GPS situation. * New AVL ID 69 value added (4 - no GPS in Static Navigation). * Improved Recovery mode trigger logic in Lost Sensor scenario. * Added error code when BLE sensor is lost. |
| VERSION | RELEASE DATE | CONFIGURATOR CHANGES | FIRMWARE CHANGES |
|---|---|---|---|
Firmware version: 55.00.16.Rev.564BlueNRG version: 10.4.12 for TAT100 HW ver.: 31 |
2024.03.12 |
* Fixed configurator crash after firmware update. * Added cell ID I/O elements * Fixed error when disabling BLE features in configuration. * Added GSM area code I/O element * Simplified EYE sensor configuration. * Added Autonomous Alarm System feature. |
* Fixed periodic timer starting in Recovery mode. * Improved backup tracker scan procedure. * Fixed issue with GPS fix with First Power On record. * Improved energy management in sleep mode when device is in motion. * Fixed crash on BLE sensor alarm. * Bluetooth scanning and data parsing optimization. * DNS resolve improvements. * Fixed periodic timer starting when tracking scenario selected as None. * Changed default movement sensitivity to 150 mG * Changed default GNSS mode to GLONASS, GPS and GALILEO * Fixed EYE sensor data multiplier for correct data displaying. * Fixed issue if GPRS is lost during record sending. * Fixed GPRS command processing in UDP mode. * Improved received SMS reading process. * Improved connection to Fota process. * Fixed BLE sensor data not being included in periodic records. * Improved static navigation logic. * Improved Bluetooth scan stability. * Added BLE beacons for Recovery mode trigger. * Movement logic rework. * Added condition to stop GNSS search if less than 3 satellites found in the first 60 seconds. |
Firmware version: 55.00.16.Rev.545BlueNRG version: 10.3.12 for TAT100 HW ver.: 31 |
2022.08.23 |
* No changes |
*Fixed issue with incorrectly detected SIM slot for eSIM devices. |
| Firmware version: 55.00.16.Rev.543 BlueNRG version: 10.3.12 for TAT100 HW ver.: 31 0.3.12 for TAT100 HW ver.: 62 Configurator version: 1.7.16_E.TAT100.R23 RELEASE |
2022.08.08 |
* Updated Teltonika Configurator version to set Central device default IMEI to 300000000000000 * Added Recovery mode option * Added I/O element of Recovery Mode * Added more options of movement sensitivity threshold [50-1000mG] * Configurator for BLE FW and Backup FW was merged into one. |
*SMS command created for getting device statistics *Protection from writing other devices FW *Added condition to prevent modem waking up at midnight if scheduler is configured *Added reconfiguration mechanism that lets FW work with / without SMPS filterMissing *Fixed issue of missing 4th sensor's data with Monitoring operand *Fixed too frequent / unnecessary scans with all sensors configured as monitoring *Fixed sensors scan starting with monitoring operand when Backup tracker is configured *Backup tracker scan not starting right after *Time synchronization every 24 hours *Fixed LBS data sending issue *New AVL ID 20015 for Modem UpTime (in seconds) *Added response sending if recovery command is sent through GPRS *The next periodic record after Recovery mode deactivation being sent with AVL ID 20012 - fixed *Reduced EQ Core update frequency *Fixed battery consumption issue when GSM is jammed. *LED status changed from constant on to blinking mode to save the battery * Added Recovery mode feature * Implemented Recovery mode activation from the Backup tracking alarm * Added EYE sensors support * Fixed Minor bugs regarding the sensors * Fixed Short period Recovery Mode records * Extended Backup Tracker: Central device IMEI range * Backup tracker: Scanning logic has been changed, scan duration is not configurable anymore, it is up to 60 seconds by default now. * Implemented Record timestamp shift feature * Fixed BLE sensor records with wrong event ID being sent * Fixed BLE sensor record duplicates with |
| Firmware version: 55.00.16.Rev.522 BlueNRG version: 10.2.21.Rev.01 Configurator version: 1.7.16_R.TAT100.R2 |
2021.12.21 |
* Improved battery safety features * Fixed stuck download during FOTA update * Fixed device not restarting to update FW after FOTA download * Improved main device packet filtering * Improved battery voltage measurement * Fixed the device not restarting after FOTA WEB update when it happens at the same time as periodic record * Fixed random statistic losses * Fixed GNSS module status not being accurate in Teltonika Configurator * Improved static navigation mode * Fixed scheduler time resync timer not working properly * Fixed statistic not being deleted from RAM | |
| Firmware version: 55.00.15.Rev.519 BlueNRG version: 10.2.14 Configurator version: 1.7.16_R.TAT100.R2 |
2021.10.19 |
* Fixed fake movement detection on startup * Fixed problem when the device is stuck in On Stop tracking mode after reconfiguration * Added Power-On reason data and fixed version changes to device statistics * Fixed Backup tracker issue where the alarm mode is not immediately activated when the central device disappears * Fixed empty GSM I/O elements * Fixed an issue where UTC is added after each reconfiguration * Added record printing to * Improved GNSS module control with | |
| 55.00.10.Rev.509 BlueNRG: 10.2.3_Rev.00 1.7.16_E.TAT100_04 |
2021.05.10 |
* Added |
* Implemented
|
| 55.00.05.Rev.510 BlueNRG: 0.1.7 |
2020.12.03 |
* Removed tracking scenarios * Removed speed source parameter * Removed record saving/sending without TS parameter * Removed LED Indication parameter * Removed NTP resync parameter |
* Implemented FOTA support. * Improved GNSS position capturing. * Reworked Periodic and Scheduler tracking counters. * Implemented device logging via USB. * Implemented statistics acquisition to flash memory. |
| 55.00.05.Rev.507 BlueNRG: 0.1.5 |
2020.09.29 |
* Implemented GNSS Source configuration. Available options: BeiDou, GLONASS, Galileo and GPS. * Added I/O elements: Data Mode, GSM Signal, GNSS Status, GNSS PDOP, GNSS HDOP, Speed, GSM Cell ID, GSM Area Code, Battery Voltage, Active GSM Operator, ICCID, Coordinates ISO6709. * Added SMS command autorization via Login and Password logic. |
* Implemented 'Codec 8', 'Codec 8 Extended' and 'Codec 12' protocols. * Implemented NTP, NITZ and GNSS time synchronization sources. * Implemented ability to send GPRS data from device via TCP or UDP channels. * Implemented connection to server timeouts. * Ported TLS encryption functionality from other Teltonika devices. * Implemented Periodic and Scheduler tracking. * Implemented BlueNRG firmware update via GPRS. This function will be used to reflash BlueNRG firmware via FOTA WEB. * Added GSM number authorization logic. |