From Teltonika Telematics Wiki
VERSION
|
RELEASE DATE
|
CONFIGURATOR CHANGES
|
FIRMWARE CHANGES
|
Firmware version: 55.00.16.Rev.569
BlueNRG version: 10.0.3.Rev.00 for TAT100 HW ver.: 31
1.0.3.Rev.00 for TAT100 HW ver.: 62
Configurator version: 1.7.74_E.TAT1_R.7
|
2024.08.19
|
- Added an option to configure TLS functionality.
- Added an option to configure SMS record sending.
- Added an option to configure MQTT Azure and AWS support.
- Added an option to configure I am alive feature.
|
- Added TLS functionality feature.
- Added SMS record sending feature.
- Added MQTT Azure and AWS support.
- Added I am alive feature.
- Fixed X, Y and Z IO elements not being included with First Power On record.
- Extended On Stop and On Move periodic timers to maximum value of 7 days.
- Improvements to Static Navigation logic in no GPS situation.
- New AVL ID 69 value added (4 - no GPS in Static Navigation).
- Improved Recovery mode trigger logic in Lost Sensor scenario.
- Added error code when BLE sensor is lost.
|
VERSION
|
RELEASE DATE
|
CONFIGURATOR CHANGES
|
FIRMWARE CHANGES
|
Firmware version: 55.00.16.Rev.564
BlueNRG version: 10.4.12 for TAT100 HW ver.: 31
0.4.12 for TAT100 HW ver.: 62
Configurator version: 1.7.74_B.TAT1_R.6
|
2024.03.12
|
- Fixed configurator crash after firmware update.
- Added cell ID I/O elements
- Fixed error when disabling BLE features in configuration.
- Added GSM area code I/O element
- Simplified EYE sensor configuration.
- Added Autonomous Alarm System feature.
|
- Fixed periodic timer starting in Recovery mode.
- Improved backup tracker scan procedure.
- Fixed issue with GPS fix with First Power On record.
- Improved energy management in sleep mode when device is in motion.
- Fixed crash on BLE sensor alarm.
- Bluetooth scanning and data parsing optimization.
- DNS resolve improvements.
- Fixed periodic timer starting when tracking scenario selected as None.
- Changed default movement sensitivity to 150 mG
- Changed default GNSS mode to GLONASS, GPS and GALILEO
- Fixed EYE sensor data multiplier for correct data displaying.
- Fixed issue if GPRS is lost during record sending.
- Fixed GPRS command processing in UDP mode.
- Improved received SMS reading process.
- Improved connection to Fota process.
- Fixed BLE sensor data not being included in periodic records.
- Improved static navigation logic.
- Improved Bluetooth scan stability.
- Added BLE beacons for Recovery mode trigger.
- Movement logic rework.
- Added condition to stop GNSS search if less than 3 satellites found in the first 60 seconds.
|
Firmware version: 55.00.16.Rev.545
BlueNRG version: 10.3.12 for TAT100 HW ver.: 31
0.3.12 for TAT100 HW ver.: 62
Configurator version: 1.7.16_E.TAT100.R23 RELEASE
|
2022.08.23
|
|
- Fixed issue with incorrectly detected SIM slot for eSIM devices.
|
Firmware version: 55.00.16.Rev.543 BlueNRG version: 10.3.12 for TAT100 HW ver.: 31 0.3.12 for TAT100 HW ver.: 62 Configurator version: 1.7.16_E.TAT100.R23 RELEASE
|
2022.08.08
|
- Updated Teltonika Configurator version to set Central device default IMEI to 300000000000000
- Added Recovery mode option
- Added I/O element of Recovery Mode
- Added more options of movement sensitivity threshold [50-1000mG]
- Configurator for BLE FW and Backup FW was merged into one.
|
- SMS command created for getting device statistics
- Protection from writing other devices FW
- Added condition to prevent modem waking up at midnight if scheduler is configured
- Added reconfiguration mechanism that lets FW work with / without SMPS filterMissing
- Fixed issue of missing 4th sensor's data with Monitoring operand
- Fixed too frequent / unnecessary scans with all sensors configured as monitoring
- Fixed sensors scan starting with monitoring operand when Backup tracker is configured
- Backup tracker scan not starting right after
- Time synchronization every 24 hours
- Fixed LBS data sending issue
- New AVL ID 20015 for Modem UpTime (in seconds)
- Added response sending if recovery command is sent through GPRS
- The next periodic record after Recovery mode deactivation being sent with AVL ID 20012 - fixed
- Reduced EQ Core update frequency
- Fixed battery consumption issue when GSM is jammed.
- LED status changed from constant on to blinking mode to save the battery
- Added Recovery mode feature
- Implemented Recovery mode activation from the Backup tracking alarm
- Added EYE sensors support
- Fixed Minor bugs regarding the sensors
- Fixed Short period Recovery Mode records
- Extended Backup Tracker: Central device IMEI range
- Backup tracker: Scanning logic has been changed, scan duration is not configurable anymore, it is up to 60 seconds by default now.
- Implemented Record timestamp shift feature
- Fixed BLE sensor records with wrong event ID being sent
- Fixed BLE sensor record duplicates with
On change operand
- Fixed BLE sensor
On Exit record not generating when switching to sleep mode
- Fixed
Custom1 sensor data in SMS being sent as NaN (empty)
- Fixed duplicate BLE sensor data after waking up
- Changed required packets amount in backup tracker scenario and minimal scan duration
- Fixed backup tracker alarm not triggering just before wakeup
- Fixed backup tracker not detecting enough packets during BLE scan
- Periodic records do not affect backup tracker alarm record generation
|
Firmware version: 55.00.16.Rev.522 BlueNRG version: 10.2.21.Rev.01 Configurator version: 1.7.16_R.TAT100.R2
|
2021.12.21
|
|
- Improved battery safety features
- Fixed stuck download during FOTA update
- Fixed device not restarting to update FW after FOTA download
- Improved main device packet filtering
- Improved battery voltage measurement
- Fixed the device not restarting after FOTA WEB update when it happens at the same time as periodic record
- Fixed random statistic losses
- Fixed GNSS module status not being accurate in Teltonika Configurator
- Improved static navigation mode
- Fixed scheduler time resync timer not working properly
- Fixed statistic not being deleted from RAM
|
Firmware version: 55.00.15.Rev.519 BlueNRG version: 10.2.14 Configurator version: 1.7.16_R.TAT100.R2
|
2021.10.19
|
|
- Fixed fake movement detection on startup
- Fixed problem when the device is stuck in On Stop tracking mode after reconfiguration
- Added Power-On reason data and fixed version changes to device statistics
- Fixed Backup tracker issue where the alarm mode is not immediately activated when the central device disappears
- Fixed empty GSM I/O elements
- Fixed an issue where UTC is added after each reconfiguration
- Added record printing to
Dump log
- LBS data is not included in records if GNSS fix was caught
- Fixed NTP timesync failure if offset is zero
- Improved record creation (wake up from sleep) during Backup tracker alarms
- Improved GNSS module control with
Static Navigation and LBS
- Added prevention from inappropriate record generation if the battery is low (HW watchdog)
- Added statistic element for USB connected uptime
- Added timestamp to BlueNRG serial prints
- Minor improvement for BlueNRG firmware update via configurator
- Added filter for
LBS cell_id duplicates
- Improved Bluetooth sensor record creation with
'On Change' operand
- Added Bluetooth sensor support
- Added condition to skip LBS data update if location source is only GNSS
- Increased retries of AT+# command in order to avoid empty LBS data from modem
- Changed
Open link timeout to 15s
- Fixed an issue where the tracking mode would change from the scheduler to periodic
- Improved logic for multiple
FOTA Web tasks update in the same connection
- Implemented rule for additional connection to
FOTA Web after baseband firmware update
- Added accelerometer version information inside '.info' serial command
- Fixed an issue with battery voltage
I/O element when record saving is overlapping with a firmware update
- Fixed
Scheduler record sending at midnight
- Fixed missed LBS values inside
I/O elements
- Fixed an issue when GNSS speed is not zero while the device is in a stationary position
- General minor improvements
|
55.00.10.Rev.509 BlueNRG: 10.2.3_Rev.00 1.7.16_E.TAT100_04
|
2021.05.10
|
- Added
Test Connection button
- Temporarily removed
Secondary Server Settings
- Tracking Period default value changed to 28800 (s)
|
- Implemented
Test Connection feature.
- Added BlueNRG logging to DUMP files
- Added LBS data logging to DUMP files
- Added protection that blocks FMB firmware flash to AT devices
- Added time-sync update with asset purpose command
- Improved periodic record timer logic
- Improved battery voltage measurement
- Improved periodic GPRS data sending while USB is connected to the device
- Disabled SMPS filter
- Fixed record sending when movement is triggered at all times
- Improved NTP time-sync
|
55.00.05.Rev.510 BlueNRG: 0.1.7
|
2020.12.03
|
- Removed tracking scenarios
- Removed speed source parameter
- Removed record saving/sending without TS parameter
- Removed LED Indication parameter
- Removed NTP resync parameter
|
- Implemented FOTA support.
- Improved GNSS position capturing.
- Reworked Periodic and Scheduler tracking counters.
- Implemented device logging via USB.
- Implemented statistics acquisition to flash memory.
|
55.00.05.Rev.507 BlueNRG: 0.1.5
|
2020.09.29
|
- Implemented GNSS Source configuration. Available options: BeiDou, GLONASS, Galileo and GPS.
- Added I/O elements: Data Mode, GSM Signal, GNSS Status, GNSS PDOP, GNSS HDOP, Speed, GSM Cell ID, GSM Area Code, Battery Voltage, Active GSM Operator, ICCID, Coordinates ISO6709.
- Added SMS command autorization via Login and Password logic.
|
- Implemented 'Codec 8', 'Codec 8 Extended' and 'Codec 12' protocols.
- Implemented NTP, NITZ and GNSS time synchronization sources.
- Implemented ability to send GPRS data from device via TCP or UDP channels.
- Implemented connection to server timeouts.
- Ported TLS encryption functionality from other Teltonika devices.
- Implemented Periodic and Scheduler tracking.
- Implemented BlueNRG firmware update via GPRS. This function will be used to reflash BlueNRG firmware via FOTA WEB.
- Added GSM number authorization logic.
|