FMB110 General description

From Wiki Knowledge Base | Teltonika GPS
Revision as of 08:33, 23 May 2018 by Simkunas.ma (talk | contribs) (Created page with "{{Template:FMB General description|model=FMB110}} {{FMB110 Package contents}} ==Basic characteristics== {{Template:FMB Basic characteristics}} {{FMB110 Hardware features}...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > Advanced Trackers > FMB110 > FMB110 Manual > FMB110 General description

FMB110 is a tracking terminal with GNSS and GSM connectivity, which is able to collect device coordinates and transfer them via GSM network to a server. This device is perfectly suitable for applications, which require the location acquirement of remote objects.

Template:FMB110 Package contents

Basic characteristics

GSM / GPRS / GNSS features:

  • Teltonika TM2500 quad band module (GSM 850 / 900 / 1800 / 1900 MHz);
  • GPRS Multi-Slot class 12 (Up to 85,6 kbps);
  • SMS (text, data);
  • Integrated GNSS receiver;
  • Up to -165 dBm GNSS receiver sensitivity.


Template:FMB110 Hardware features


Template:FMB110 Interface features


Special features:

  • Fast position fix (Outdoor areas);
  • High Quality track even in high density urban canyon;
  • Ultra small case;
  • Ready for harsh environment;
  • Easy to mount in limited access areas;
  • Firmly fasten;
  • 2 LED status indication;
  • Real time tracking;
  • Smart data acquisition based on:
    • Time;
    • Speed;
    • Angle;
    • Distance;
    • Ignition or any other I/O event;
  • Sending acquired data via GPRS;
  • GPRS and SMS I/O events;
  • Virtual odometer;
  • Jamming detection;
  • Configurable using Secured SMS Commands;
  • 1x micro SIM card; 1x eSIM;
  • Overvoltage protection;


Template:FMB Supply voltage

Technical features

Part name Physical specification
Navigation indication LED
Modem indication LED
Socket Soldered inner socket
USB Micro USB socket
GNSS Internal GNSS antenna
GSM Internal GSM antenna
Technical details
2 W max.
Current consumption at 12 V
GPRS: average 69.15 mA rms
Nominal: average 35.23 mA rms
GNSS sleep: average 19.72 mA
Deep Sleep: average 7.35 mA
Online Deep Sleep: average 10.96 mA
Ultra Deep Sleep: average 5.69 mA
Battery charge current Average 140 mA
Operating temperature -25..+55 °C
Storage temperature -40..+70 °C
Storage relative humidity 5..95% (no condensation)
Device + case + battery weight 55 g

Dimension drawing:

Technical information about internal battery


Internal back-up battery Battery voltage (V) Nominal Capacity (mAh) Power (Wh) Charge temperature (°C) Discharge temperature (°C) Storage temperature (°C)
Li-ion rechargeable battery 3.75~3.90 170 0.64 – 0.66 0 to +45 -20 to +60 -20 to +45 for 1 month
-20 to +35 for 6 months

Batteries are covered by 6 month warranty support.

Bw nb.png CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Bw disposal.png Battery should not be disposed of into general household waste.
Bring damaged or worn-out batteries to your local recycling center or dispose them into a battery recycle bin commonly found in supermarkets.

Electrical characteristics


Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage:
Supply Voltage
(Recommended Operating Conditions)
+10 +30 V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF) 120 µA
Drain current
(Digital Output ON, Recommended Operating Conditions)
0.1 0.5 A
Static Drain-Source resistance
(Digital Output ON)
400 600
Digital Input:
Input resistance (DIN1) 47
Input resistance (DIN2) 51.7
Input resistance (DIN3) 47
Input voltage
(Recommended Operating Conditions)
0 Supply voltage V
Input Voltage threshold (DIN1) 7.5 V
Input Voltage threshold (DIN2) 2.5 V
Input Voltage threshold (DIN3) 2.5 V
Analog Input:
Input voltage
(Recommended Operating Conditions), Range 1
0 +10 V
Input resistance, Range 1 150
Measurement error on 12V, Range 1 3 %
Additional error on 12 V, Range 1 360 mV
Measurement error on 30 V, Range 1 3 %
Additional error on 30 V, Range 1 900 mV
Input Voltage
(Recommended Operating Conditions), Range 2
0 +30 V
Input resistance, Range 2 150
Measurement error on 12V, Range 2 3 %
Additional error on 12 V, Range 2 360 mV
Measurement error on 30 V, Range 2 3 %
Additional error on 30 V, Range 2 900 mV
Output Supply Voltage 1-Wire:
Supply voltage +4.5 +4.7 V
Output inner resistance 7 Ω
Output current (Uout > 3.0 V) 30 mA
Short circuit current (Uout = 0) 75 mA
Ground sense:
Input resistance 38.45
Input voltage
(Recommended operating conditions)
0 Supply voltage V
Input voltage threshold 0.5 V
Sink current 180 nA


CAN interface:
Internal terminal resistor CAN bus
(no internal termination resistor)
- - - Ω
Differential input resistance 19 30 52
Recessive output voltage 2 2.5 3 V
Differential receiver threshold Voltage 0.5 0.7 0.9 V
Common mode input voltage -30 - 30 V


Alert.png
Analog Input error margin can increase if temperature varies.

Absolute maximum ratings

Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage
(Absolute Maximum Ratings)
-32 +32 V
Drain-Source clamp threshold voltage
(Absolute Maximum Ratings), (Idrain = 2 mA)
+36 V
Digital Input Voltage
(Absolute Maximum Ratings)
-32 +32 V
Analog Input Voltage
(Absolute Maximum Ratings)
-32 +32 V