Template:FMA SMS/GPRS command list
Read chapter 5.10 to know how to construct a proper SMS message and send it to FMA1YX device. All commands are case sensitive. While FMA1YX operates in Deep Sleep mode and user tries to send SMS message it cannot arrive to FMA1YX device, because GSM/GPRS module is disabled most of the time (wake up depends on Send Period parameter). FMA1YX will receive the SMS when it wakes up (exits deep sleep mode).
SMS command list
Command | Description | Response |
---|---|---|
getstatus | Modem Status information. | Yes |
getweektime | Current device time, Day of Week and amount of minutes passed since start of week | Yes |
getops | List of currently available GSM operator | Yes |
getcfgtime | Date and Time of last successful configuration | Yes |
ggps | Returns location information with Google maps link. | Yes |
getgps | Current GPS data, date and time. | Yes |
cpureset | Resets device. | No |
resetprof | Reset all FLASH1 profile configuration to default profile | No |
getver | Device / Modem / Code version information. | Yes |
getinfo | Device runtime system information. | Yes |
deleterecords | Delete all records saved on FLASH | Yes |
getio | Readout analog input,digital input and output. | Yes |
readio # | Returns IO status, # AVL ID. | Yes |
setdigout ## Y1 Y2 | Set digital output. 1.# – 0 or 1 (0 - OFF or 1 – ON) for DOUT1. |
Yes |
setdigout X Z Y | set selected digital output X – number of Digital output (1 – digital output 1; 2 – digital output 2). |
Yes |
getparam # | Returns selected parameter value, # param ID. | Yes |
getparam 1271 X | X values can be 1,2,3. | Yes |
setparam #:# | Sets selected parameter value. 1.# - ID value. |
Yes |
flush #,#,#,#,#,#,# | Initiates all data sending to specified target server. 1.# - IMEI. |
No |
readops # | 1 – send first 20 operator codes 2 – send from 21st to 40th operator codes. |
No |
sn # | Static navigation, 1 – enable, 0 – disable | Yes |
banlist # | Banned operators information. | Yes |
setkey # # | Add new or change current configuration keyword. 1.# - old keyword (if adding new keyword space). |
Yes |
delkey # | Remove existing keyword. 1.# - old keyword. |
Yes |
crashlog # | Device last information before unexpected reset. | Yes |
delete_all_sms | Deletes all SMS | No |
Command | Description | Response |
---|---|---|
fc_reset | Resets fuel consumption parameters. | Yes |
towingreact | Towing reactivation. | Yes |
auto_calibrate:set | Calibrate position if car accelerate straight to > 30 km/h for 5 sec. | Yes |
auto_calibrate:get | Returns the state of calibration. | Yes |
odoset:# | Set total odometer value. # - new odometer value in km. |
Yes |
odoget | Display current odometer value. | Yes |
on_demand_trackingX | X=0 – Stops Tracking on Demand functionality. X=1 – Starts Tracking on Demand functionality. X=2 – Generates one high priority record and inititates data sending to server. |
Yes |
Command | Description | Response |
---|---|---|
btgetlist # | Returns requested Bluetooth list. # - 0,1 or 2 (0 – Discovered, 1 – Paired, 2 – Connected). |
Yes |
btscan | Starts Bluetooth scan. | Yes |
btvisible # | Sets Bluetooth to visible with TMO. # - visibility TMO (from 1 to 255 seconds). |
Yes |
btrelease # | Disconnects from current device and pauses auto connect functionality for TMO. # - none or TMO (from 1 to 255 seconds). |
Yes |
btunpair # | Unpair Bluetooth device. # - all, BT address (all – unpair all devices, BT address – unpair only specified MAC address). |
Yes |
Command | Description | Response |
---|---|---|
obdinfo | If connected with Blue-tooth OBD dongle displays all available information from OBD. | Yes |
faultcodes | If connected with Blue-tooth OBD dongle display all visible fault codes. | Yes |
cleardtc | Clears all vehicle stored fault codes. | No |
getvin | Get vehicle VIN code, if OBD dongle is connected. | Yes |
Command | Description | Response |
---|---|---|
lvcansetprog # | Set program number to LV-CAN200/ ALL-CAN300 that is connected to FMB1YX. # three digit number that identity vehicle. |
Yes |
lvcansimpletacho # | Add or remove simpletacho start byte. # - 0 or 1 (0 – don’t add start byte, 1 – add start byte). |
No |
lvcangetprog | Get program number from LV-CAN200/ ALL-CAN300 that is connected to FMB1YX. | Yes |
lvcangetinfo | Get information about connected LV-CAN200/ALL-CAN300. | Yes |
lvcanclear # | Clear Total Mileage (counted), Engine Work Time (counted), Fuel Consumed (counted) parameters values. # - parameter (0 – Engine work time (counted), 1 – Fuel Consumed (counted), 2 – Vehicle Mileage (counted)).. |
Yes |
allcanmode | Turn on ALL-CAN300 mode. | Yes |
lvcanmode | Turn on LV-CAN200 mode. | Yes |
lvcanfaultcodes | Read DTC fault codes. | Yes |