From Wiki Knowledge Base | Teltonika GPS
(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Green driving parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11000
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11004
|
Uint8
|
2.5
|
0.5
|
10
|
m/s2
|
Max acceleration
|
11005
|
Uint8
|
2.7
|
0.5
|
10
|
m/s2
|
Max braking
|
11006
|
Uint8
|
3.4
|
0.5
|
10
|
m/s2
|
Max cornering
|
11007
|
Uint8
|
0
|
0
|
1
|
0 – GPS
|
Source
|
1 – Accelerometer
|
11008
|
uint8
|
0
|
0
|
1
|
Enable/Disable
|
Duration
|
11003
|
Uint8
|
0
|
0
|
2 (1 for FMB125)
|
0 – None
|
Output control
|
1 – DOUT 1
|
2 – DOUT 2
|
11001
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT ON duration
|
11002
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT OFF duration
|
7034
|
Uint8
|
0
|
0
|
10
|
Phone number
|
Send SMS to
|
8034
|
String
|
"Green Driving"
|
0
|
160
|
Text
|
Sms text
|
Overspeeding scenario parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11100
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11104
|
Uint16
|
90
|
0
|
260
|
km/h
|
Max speed
|
11103
|
Uint8
|
0
|
0
|
2 (1 for FMB125)
|
0 – None
|
Output control
|
1 – DOUT 1
|
2 – DOUT 2
|
11101
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT ON duration
|
11102
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT OFF duration
|
7032
|
Uint8
|
0
|
0
|
10
|
Phone number
|
Send SMS to
|
8032
|
String
|
"Overspeeding"
|
0
|
160
|
Text
|
Sms text
|
Jamming scenario parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11300
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11303
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Eventual records
|
1 – Enable
|
11304
|
Uint8
|
0
|
0
|
2 (1 for FMB125)
|
0 – None
|
Output control
|
1 – DOUT1
|
2 – DOUT2
|
11301
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT ON duration
|
11302
|
Int32
|
200
|
0
|
2147483647
|
Milliseconds
|
DOUT OFF duration
|
11305
|
Uint16
|
60
|
0
|
65535
|
Seconds
|
Timeout
|