Template:FMB OBD Device Family Features Parameter list

From Wiki Knowledge Base | Teltonika GPS

Green driving parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11000 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11004 Uint8 2.5 0.5 10 m/s2 Max acceleration
11005 Uint8 2.7 0.5 10 m/s2 Max braking
11006 Uint8 3.4 0.5 10 m/s2 Max cornering
11007 Uint8 0 0 1 0 – GPS Source
1 – Accelerometer
11008 uint8 0 0 1 Enable/Disable Duration
11003 Uint8 0 0 2 (1 for FMB125) 0 – None Output control
1 – DOUT 1
2 – DOUT 2
11001 Int32 200 0 2147483647 Milliseconds DOUT ON duration
11002 Int32 200 0 2147483647 Milliseconds DOUT OFF duration
7034 Uint8 0 0 10 Phone number Send SMS to
8034 String "Green Driving" 0 160 Text Sms text

Overspeeding scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11100 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11104 Uint16 90 0 260 km/h Max speed
11103 Uint8 0 0 2 (1 for FMB125) 0 – None Output control
1 – DOUT 1
2 – DOUT 2
11101 Int32 200 0 2147483647 Milliseconds DOUT ON duration
11102 Int32 200 0 2147483647 Milliseconds DOUT OFF duration
7032 Uint8 0 0 10 Phone number Send SMS to
8032 String "Overspeeding" 0 160 Text Sms text

Jamming scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11300 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11303 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11304 Uint8 0 0 2 (1 for FMB125) 0 – None Output control
1 – DOUT1
2 – DOUT2
11301 Int32 200 0 2147483647 Milliseconds DOUT ON duration
11302 Int32 200 0 2147483647 Milliseconds DOUT OFF duration
11305 Uint16 60 0 65535 Seconds Timeout