From Teltonika Telematics Wiki
System parameters
System Settings
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 138
|
Uint8
|
1
|
0
|
2
|
0 – Ignition
|
Movement Source
|
| 1 – Accelerometer
|
| 2 – GNSS
|
| 3 – CAN speed
|
| 133
|
Uint8
|
0
|
0
|
1
|
0 – GNSS
|
Speed Source
|
| 1 – CAN
|
| 107
|
Uint8
|
2
|
0
|
2
|
0 – After Position Fix
|
Records Saving/Sending without TS
|
| 1 – Always
|
| 2 – After Time Sync
|
| 123
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
PDOP filter
|
| 1 – Enable
|
| 124
|
Uint16
|
0,7
|
0
|
99
|
-
|
PDOP filter Threshold
|
| 108
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
LED indication
|
| 1 – Enable
|
| 109
|
Uint8
|
10
|
1
|
15
|
0 – Undefined
|
GNSS source
|
| 1 – Beidou only
|
| 2 – Glonass only
|
| 3 – Glonass and Beidou not allowed
|
| 4 – Galileo only
|
| 5 – Galileo and Beidou
|
| 6 – Galileo and Glonass
|
| 7 – Galileo, Glonass and Beidou not allowed
|
| 8 – Gps only
|
| 9 – Gps and Beidou
|
| 10 – Gps and Glonass
|
| 11 – Gps, Glonass and Beidou not allowed
|
| 12 – Gps and Galileo
|
| 13 – Gps, Galileo and Beidou
|
| 14 – Gps, Galileo and Glonass
|
| 15 – Gps, Galileo, Glonass and Beidou and not allowed
|
| 111
|
Uint8
|
1
|
0
|
1
|
0 – Range 15V
|
Analog Input Value Range
|
| 1 – Range 150V
|
| 113
|
Uint8
|
1
|
0
|
1
|
0 – Codec 8
|
Data Protocol
|
| 1 – Codec 8 Extended
|
| 110
|
Uint8
|
0
|
0
|
1
|
0 – On need
|
Battery Charge Mode
|
| 1 – After Ignition ON
|
| 2 – Always
|
| 114
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Power On By USB/Charger
|
| 1 – Enable
|
| 131
|
Uint8
|
10
|
5
|
10
|
5 – Digital Input 3 + Digital Input 4
|
Input/Output Mode
|
| 6 – Digital Output 1 + Digital Input 4
|
| 9 – Digital Input 3 + Digital Output 2
|
| 10 – Digital Output 1 + Digital Output 2
|
Static Navigation Settings
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 106
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Static navigation
|
| 1 – Enable
|
| 112
|
Uint8
|
0
|
0
|
1
|
0 – Movement Source
|
Static Navigation Source
|
| 1 – Ignition Source
|
Call Duration Limits
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 3030
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Other Calls Duration
|
| 3031
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Alarm Button Call Action Duration Limit
|
| 3032
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Power Button Call Action Duration Limit
|
| 3033
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Button 1 Call Action Duration Limit
|
| 3034
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Button 2 Call Action Duration Limit
|
| 3035
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Button 3 Call Action Duration Limit
|
Sleep Mode
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 102
|
Uint8
|
2
|
0
|
4
|
0 – Disable
|
Sleep settings
|
| 1 – GPS sleep
|
| 2 – Deep sleep
|
| 3 – Online Deep sleep
|
| 4 – Ultra sleep
|
| 132
|
Uint8
|
2
|
0
|
2
|
0 - Movement only
|
Sleep Exit Source
|
| 1 - Alarm button only
|
| 2 - Movement + Alarm button
|
| 103
|
Uint16
|
1
|
1
|
3000
|
Minutes
|
Timeout
|
Ignition Source
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 104
|
Uint8
|
30000
|
13200
|
100000
|
mV
|
High Voltage
|
| 105
|
Uint8
|
13200
|
0
|
30000
|
mV
|
Low Voltage
|
| 101
|
Uint16
|
2
|
1
|
103
|
1 - DIN1
|
Low Voltage
|
| 2 - Accelerometer
|
| 3 - DIN1 + Accelerometer
|
| 4 - Power Voltage
|
| 5 - DIN1 + Power Voltage
|
| 6 - Accelerometer + Power Voltage
|
| 7 - DIN1 + Accelerometer + Power Voltage
|
| 32 - DIN3
|
| 33 - DIN1 + DIN3
|
| 34 - Accelerometer + DIN3
|
| 35 - DIN1 + Accelerometer + DIN3
|
| 36 - Power Voltage + DIN3
|
| 37 - DIN1 + Power Voltage + DIN3
|
| 38 - Accelerometer + Power Voltage + DIN3
|
| 39 - DIN1 + Accelerometer + Power Voltage + DIN3
|
| 64 - DIN4
|
| 65 - DIN1 + DIN4
|
| 66 - Accelerometer + DIN4
|
| 67 - DIN1 + Accelerometer + DIN4
|
| 68 - Power Voltage + DIN4
|
| 69 - DIN1 + Power Voltage + DIN4
|
| 70 - Accelerometer + Power voltage + DIN4
|
| 71 - DIN1 + Accelerometer
|
| 96 - DIN3 + DIN4
|
| 97 - DIN1 + DIN3 + DIN4
|
| 98 - Accelerometer + DIN3 + DIN4
|
| 99 - DIN1 + Accelerometer + DIN3 + DIN4
|
| 100 - Power Voltage + DIN3 + DIN4
|
| 101 - DIN1 + Power Voltage + DIN3 + DIN4
|
| 102 - Accelerometer + Power Voltage + DIN3 + DIN4
|
| 103 - DIN1 + Accelerometer + Power Voltage + DIN3 + DIN4
|
Accelerometer Delay Settings
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 19001
|
Uint16
|
5
|
1
|
60
|
Seconds
|
Movement Start Delay
|
| 19002
|
Uint16
|
60
|
5
|
300
|
Seconds
|
Movement Stop Delay
|
| 19000
|
Uint16
|
2
|
0
|
4
|
0 – Minimal
|
Accelerometer sensitivity in sleep
|
| 1 – Reduced
|
| 2 – Normal
|
| 3 – Increased
|
| 4 – Maximum
|
Time Synchronization
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 901
|
Uint8
|
3
|
0
|
24
|
Hours
|
NTP Resync
|
| 902
|
Char
|
"avl1.teltonika.lt"
|
0
|
55
|
String
|
NTP server 1
|
| 903
|
Char
|
"pool.ntp.org"
|
0
|
55
|
String
|
NTP server 2
|
Accelerometer Auto Calibration
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 169
|
Uint16
|
2
|
0
|
2
|
0 - Disabled
|
Accelerometer Auto Calibration
|
| 1 - Once
|
| 2 - Continuous
|
| 170
|
Uint16
|
1
|
0
|
1
|
0 - Disable
|
Gravity Filter
|
| 1 - Enable
|
Tracking Mode
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 909
|
Uint8
|
0
|
0
|
1
|
0 - Performance
|
Power Saving mode
|
| 1 - Low Power
|
| 905
|
Uint16
|
1.3
|
0.1
|
5
|
Value
|
GPS accuracy: HDOP PDOP VDOP
|
| 906
|
Uint16
|
5
|
4
|
255
|
Value
|
GPS Satellites Quantity
|
Timestamp Backup
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 140
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Timestamp Backup
|
| 1 – Enable
|
Heart Rate Alert
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 1800
|
Uint8
|
0
|
1
|
0
|
0 – Disable
|
Heart Rate Alert Enable
|
| 1 – Enable
|
| 1801
|
Uint8
|
-
|
-
|
12 Symbols
|
Value
|
Mac Address
|
| 1802
|
Uint8
|
600
|
30
|
86400
|
Seconds
|
Scan Period
|
| 3006
|
Uint8
|
UTC+0
|
UTC-12
|
UTC+14
|
Time Zone
|
SMS Event/Xiaomi Mi Band 2 Time Zone
|
| 1803
|
Uint8
|
50
|
0
|
[Value of ID1804]
|
BPM
|
Min Heart rate
|
| 1804
|
Uint8
|
130
|
[Value of ID1803]
|
255
|
BPM
|
Max Heart rate
|
| 1805
|
Uint8
|
0
|
0
|
10
|
Number
|
Call To
|