From Wiki Knowledge Base | Teltonika GPS
System parameters
System Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
138
|
Uint8
|
1
|
0
|
2
|
0 – Ignition
|
Movement Source
|
1 – Accelerometer
|
2 – GNSS
|
3 – CAN speed
|
133
|
Uint8
|
0
|
0
|
1
|
0 – GNSS
|
Speed Source
|
1 – CAN
|
107
|
Uint8
|
2
|
0
|
2
|
0 – After Position Fix
|
Records Saving/Sending without TS
|
1 – Always
|
2 – After Time Sync
|
123
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
PDOP filter
|
1 – Enable
|
124
|
Uint16
|
0,7
|
0
|
99
|
-
|
PDOP filter Threshold
|
108
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
LED indication
|
1 – Enable
|
109
|
Uint8
|
10
|
1
|
15
|
0 – Undefined
|
GNSS source
|
1 – Beidou only
|
2 – Glonass only
|
3 – Glonass and Beidou not allowed
|
4 – Galileo only
|
5 – Galileo and Beidou
|
6 – Galileo and Glonass
|
7 – Galileo, Glonass and Beidou not allowed
|
8 – Gps only
|
9 – Gps and Beidou
|
10 – Gps and Glonass
|
11 – Gps, Glonass and Beidou not allowed
|
12 – Gps and Galileo
|
13 – Gps, Galileo and Beidou
|
14 – Gps, Galileo and Glonass
|
15 – Gps, Galileo, Glonass and Beidou and not allowed
|
111
|
Uint8
|
1
|
0
|
1
|
0 – Range 15V
|
Analog Input Value Range
|
1 – Range 150V
|
113
|
Uint8
|
1
|
0
|
1
|
0 – Codec 8
|
Data Protocol
|
1 – Codec 8 Extended
|
110
|
Uint8
|
0
|
0
|
1
|
0 – On need
|
Battery Charge Mode
|
1 – After Ignition ON
|
2 – Always
|
114
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Power On By USB/Charger
|
1 – Enable
|
131
|
Uint8
|
10
|
5
|
10
|
5 – Digital Input 3 + Digital Input 4
|
Input/Output Mode
|
6 – Digital Output 1 + Digital Input 4
|
9 – Digital Input 3 + Digital Output 2
|
10 – Digital Output 1 + Digital Output 2
|
Static Navigation Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
106
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Static navigation
|
1 – Enable
|
112
|
Uint8
|
0
|
0
|
1
|
0 – Movement Source
|
Static Navigation Source
|
1 – Ignition Source
|
Call Duration Limits
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3030
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Other Calls Duration
|
3031
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Alarm Button Call Action Duration Limit
|
3032
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Power Button Call Action Duration Limit
|
3033
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Button 1 Call Action Duration Limit
|
3034
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Button 2 Call Action Duration Limit
|
3035
|
Uint16
|
0 – Disabled
|
0
|
65535
|
Seconds
|
Button 3 Call Action Duration Limit
|
Sleep Mode
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
102
|
Uint8
|
2
|
0
|
4
|
0 – Disable
|
Sleep settings
|
1 – GPS sleep
|
2 – Deep sleep
|
3 – Online Deep sleep
|
4 – Ultra sleep
|
132
|
Uint8
|
2
|
0
|
2
|
0 - Movement only
|
Sleep Exit Source
|
1 - Alarm button only
|
2 - Movement + Alarm button
|
103
|
Uint16
|
1
|
1
|
3000
|
Minutes
|
Timeout
|
Ignition Source
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
104
|
Uint8
|
30000
|
13200
|
100000
|
mV
|
High Voltage
|
105
|
Uint8
|
13200
|
0
|
30000
|
mV
|
Low Voltage
|
101
|
Uint16
|
2
|
1
|
103
|
1 - DIN1
|
Low Voltage
|
2 - Accelerometer
|
3 - DIN1 + Accelerometer
|
4 - Power Voltage
|
5 - DIN1 + Power Voltage
|
6 - Accelerometer + Power Voltage
|
7 - DIN1 + Accelerometer + Power Voltage
|
32 - DIN3
|
33 - DIN1 + DIN3
|
34 - Accelerometer + DIN3
|
35 - DIN1 + Accelerometer + DIN3
|
36 - Power Voltage + DIN3
|
37 - DIN1 + Power Voltage + DIN3
|
38 - Accelerometer + Power Voltage + DIN3
|
39 - DIN1 + Accelerometer + Power Voltage + DIN3
|
64 - DIN4
|
65 - DIN1 + DIN4
|
66 - Accelerometer + DIN4
|
67 - DIN1 + Accelerometer + DIN4
|
68 - Power Voltage + DIN4
|
69 - DIN1 + Power Voltage + DIN4
|
70 - Accelerometer + Power voltage + DIN4
|
71 - DIN1 + Accelerometer
|
96 - DIN3 + DIN4
|
97 - DIN1 + DIN3 + DIN4
|
98 - Accelerometer + DIN3 + DIN4
|
99 - DIN1 + Accelerometer + DIN3 + DIN4
|
100 - Power Voltage + DIN3 + DIN4
|
101 - DIN1 + Power Voltage + DIN3 + DIN4
|
102 - Accelerometer + Power Voltage + DIN3 + DIN4
|
103 - DIN1 + Accelerometer + Power Voltage + DIN3 + DIN4
|
Accelerometer Delay Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
19001
|
Uint16
|
5
|
1
|
60
|
Seconds
|
Movement Start Delay
|
19002
|
Uint16
|
60
|
5
|
300
|
Seconds
|
Movement Stop Delay
|
19000
|
Uint16
|
2
|
0
|
4
|
0 – Minimal
|
Accelerometer sensitivity in sleep
|
1 – Reduced
|
2 – Normal
|
3 – Increased
|
4 – Maximum
|
Time Synchronization
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
901
|
Uint8
|
3
|
0
|
24
|
Hours
|
NTP Resync
|
902
|
Char
|
"avl1.teltonika.lt"
|
0
|
55
|
String
|
NTP server 1
|
903
|
Char
|
"pool.ntp.org"
|
0
|
55
|
String
|
NTP server 2
|
Accelerometer Auto Calibration
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
169
|
Uint16
|
2
|
0
|
2
|
0 - Disabled
|
Accelerometer Auto Calibration
|
1 - Once
|
2 - Continuous
|
170
|
Uint16
|
1
|
0
|
1
|
0 - Disable
|
Gravity Filter
|
1 - Enable
|
Tracking Mode
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
909
|
Uint8
|
0
|
0
|
1
|
0 - Performance
|
Power Saving mode
|
1 - Low Power
|
905
|
Uint16
|
1.3
|
0.1
|
5
|
Value
|
GPS accuracy: HDOP PDOP VDOP
|
906
|
Uint16
|
5
|
4
|
255
|
Value
|
GPS Satellites Quantity
|
Timestamp Backup
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
140
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Timestamp Backup
|
1 – Enable
|
Heart Rate Alert
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1800
|
Uint8
|
0
|
1
|
0
|
0 – Disable
|
Heart Rate Alert Enable
|
1 – Enable
|
1801
|
Uint8
|
-
|
-
|
12 Symbols
|
Value
|
Mac Address
|
1802
|
Uint8
|
600
|
30
|
86400
|
Seconds
|
Scan Period
|
3006
|
Uint8
|
UTC+0
|
UTC-12
|
UTC+14
|
Time Zone
|
SMS Event/Xiaomi Mi Band 2 Time Zone
|
1803
|
Uint8
|
50
|
0
|
[Value of ID1804]
|
BPM
|
Min Heart rate
|
1804
|
Uint8
|
130
|
[Value of ID1803]
|
255
|
BPM
|
Max Heart rate
|
1805
|
Uint8
|
0
|
0
|
10
|
Number
|
Call To
|