Template:SAS device Parameter list - System

From Teltonika Telematics Wiki

System parameters

System Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
138 Uint8 1 0 2 0 – Ignition Movement Source
1 – Accelerometer
2 – GNSS
3 – CAN speed
133 Uint8 0 0 1 0 – GNSS Speed Source
1 – CAN
107 Uint8 2 0 2 0 – After Position Fix Records Saving/Sending without TS
1 – Always
2 – After Time Sync
123 Uint8 0 0 1 0 – Disable PDOP filter
1 – Enable
124 Uint16 0,7 0 99 - PDOP filter Threshold
108 Uint8 1 0 1 0 – Disable LED indication
1 – Enable
109 Uint8 10 1 15 0 – Undefined GNSS source
1 – Beidou only
2 – Glonass only
3 – Glonass and Beidou not allowed
4 – Galileo only
5 – Galileo and Beidou
6 – Galileo and Glonass
7 – Galileo, Glonass and Beidou not allowed
8 – Gps only
9 – Gps and Beidou
10 – Gps and Glonass
11 – Gps, Glonass and Beidou not allowed
12 – Gps and Galileo
13 – Gps, Galileo and Beidou
14 – Gps, Galileo and Glonass
15 – Gps, Galileo, Glonass and Beidou and not allowed
111 Uint8 1 0 1 0 – Range 15V Analog Input Value Range
1 – Range 150V
113 Uint8 1 0 1 0 – Codec 8 Data Protocol
1 – Codec 8 Extended
110 Uint8 0 0 1 0 – On need Battery Charge Mode
1 – After Ignition ON
2 – Always
114 Uint8 1 0 1 0 – Disable Power On By USB/Charger
1 – Enable
131 Uint8 10 5 10 5 – Digital Input 3 + Digital Input 4 Input/Output Mode
6 – Digital Output 1 + Digital Input 4
9 – Digital Input 3 + Digital Output 2
10 – Digital Output 1 + Digital Output 2

Static Navigation Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
106 Uint8 1 0 1 0 – Disable Static navigation
1 – Enable
112 Uint8 0 0 1 0 – Movement Source Static Navigation Source
1 – Ignition Source

Call Duration Limits

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3030 Uint16 0 – Disabled 0 65535 Seconds Other Calls Duration
3031 Uint16 0 – Disabled 0 65535 Seconds Alarm Button Call Action Duration Limit
3032 Uint16 0 – Disabled 0 65535 Seconds Power Button Call Action Duration Limit
3033 Uint16 0 – Disabled 0 65535 Seconds Button 1 Call Action Duration Limit
3034 Uint16 0 – Disabled 0 65535 Seconds Button 2 Call Action Duration Limit
3035 Uint16 0 – Disabled 0 65535 Seconds Button 3 Call Action Duration Limit

Sleep Mode

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
102 Uint8 2 0 4 0 – Disable Sleep settings
1 – GPS sleep
2 – Deep sleep
3 – Online Deep sleep
4 – Ultra sleep
132 Uint8 2 0 2 0 - Movement only Sleep Exit Source
1 - Alarm button only
2 - Movement + Alarm button
103 Uint16 1 1 3000 Minutes Timeout

Ignition Source

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
104 Uint8 30000 13200 100000 mV High Voltage
105 Uint8 13200 0 30000 mV Low Voltage
101 Uint16 2 1 103 1 - DIN1 Low Voltage
2 - Accelerometer
3 - DIN1 + Accelerometer
4 - Power Voltage
5 - DIN1 + Power Voltage
6 - Accelerometer + Power Voltage
7 - DIN1 + Accelerometer + Power Voltage
32 - DIN3
33 - DIN1 + DIN3
34 - Accelerometer + DIN3
35 - DIN1 + Accelerometer + DIN3
36 - Power Voltage + DIN3
37 - DIN1 + Power Voltage + DIN3
38 - Accelerometer + Power Voltage + DIN3
39 - DIN1 + Accelerometer + Power Voltage + DIN3
64 - DIN4
65 - DIN1 + DIN4
66 - Accelerometer + DIN4
67 - DIN1 + Accelerometer + DIN4
68 - Power Voltage + DIN4
69 - DIN1 + Power Voltage + DIN4
70 - Accelerometer + Power voltage + DIN4
71 - DIN1 + Accelerometer
96 - DIN3 + DIN4
97 - DIN1 + DIN3 + DIN4
98 - Accelerometer + DIN3 + DIN4
99 - DIN1 + Accelerometer + DIN3 + DIN4
100 - Power Voltage + DIN3 + DIN4
101 - DIN1 + Power Voltage + DIN3 + DIN4
102 - Accelerometer + Power Voltage + DIN3 + DIN4
103 - DIN1 + Accelerometer + Power Voltage + DIN3 + DIN4

Accelerometer Delay Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
19001 Uint16 5 1 60 Seconds Movement Start Delay
19002 Uint16 60 5 300 Seconds Movement Stop Delay
19000 Uint16 2 0 4 0 – Minimal Accelerometer sensitivity in sleep
1 – Reduced
2 – Normal
3 – Increased
4 – Maximum

Time Synchronization

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
901 Uint8 3 0 24 Hours NTP Resync
902 Char "avl1.teltonika.lt" 0 55 String NTP server 1
903 Char "pool.ntp.org" 0 55 String NTP server 2

Accelerometer Auto Calibration

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
169 Uint16 2 0 2 0 - Disabled Accelerometer Auto Calibration
1 - Once
2 - Continuous
170 Uint16 1 0 1 0 - Disable Gravity Filter
1 - Enable

Tracking Mode

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
909 Uint8 0 0 1 0 - Performance Power Saving mode
1 - Low Power
905 Uint16 1.3 0.1 5 Value GPS accuracy: HDOP PDOP VDOP
906 Uint16 5 4 255 Value GPS Satellites Quantity

Timestamp Backup

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
140 Uint8 0 0 1 0 – Disable Timestamp Backup
1 – Enable

Heart Rate Alert

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1800 Uint8 0 1 0 0 – Disable Heart Rate Alert Enable
1 – Enable
1801 Uint8 - - 12 Symbols Value Mac Address
1802 Uint8 600 30 86400 Seconds Scan Period
3006 Uint8 UTC+0 UTC-12 UTC+14 Time Zone SMS Event/Xiaomi Mi Band 2 Time Zone
1803 Uint8 50 0 [Value of ID1804] BPM Min Heart rate
1804 Uint8 130 [Value of ID1803] 255 BPM Max Heart rate
1805 Uint8 0 0 10 Number Call To