Line 59: Line 59:  
* Insert data to the software, where voltage coming from Teltonika tracking unit will be converted to liters (more details can be provided by your software supplier).
 
* Insert data to the software, where voltage coming from Teltonika tracking unit will be converted to liters (more details can be provided by your software supplier).
 
==Teltonika Configurator==
 
==Teltonika Configurator==
For LLS calibration go to Maintenance under the status menu (NOTE: the status menu appears only when the FM device is physically connected to your computer)
+
For LLS calibration go to Maintenance under the status menu (NOTE: the status menu appears only when the FM device is connected to your computer)
 
Here you can choose which Analog input you will use for data reading, enter the current amount of fuel, add and remove rows.
 
Here you can choose which Analog input you will use for data reading, enter the current amount of fuel, add and remove rows.
 
<br>
 
<br>
Line 66: Line 66:  
When table is filled, calculated a0, a1, a2 and a3 values should be seen.
 
When table is filled, calculated a0, a1, a2 and a3 values should be seen.
 
<br>
 
<br>
To add a new tank fill row "''Add row''" must be clicked. "''Clear rows''" is for clearing all the rows. By clicking "''Export''" data will be exported to .csv file. To recalculate polynom "''Calculate''" must be clicked. Clicking "-" on the selected row will remove the row.
+
To add a new tank fill row "''Add row''" must be clicked. "''Clear rows''" is for clearing all the rows. By clicking "''Export''" data will be exported to .csv file. To recalculate polynom "''Calculate''" must be clicked. Clicking [[File:Delete row.png]] on the selected row will remove the row.
 +
<br>
 +
'''NOTE''': LLS calibration will not send the fuel data in liters through AIN, it is intended to help create a formula, to convert incoming data from AIN (in mV) to liters
 +
<br>
 +
<br>
 
[[File:Full Blur.gif]]
 
[[File:Full Blur.gif]]
 
<br>
 
<br>
Line 74: Line 78:  
To do that, go to I/O elements and select Analog Input 1 to Low/High priority. The Operand of the I/O element should be left as Monitoring.
 
To do that, go to I/O elements and select Analog Input 1 to Low/High priority. The Operand of the I/O element should be left as Monitoring.
 
You will see changes in fuel level expressed by the equivalent voltage read from the fuel sender wire to the Analog Input of your Teltonika device.
 
You will see changes in fuel level expressed by the equivalent voltage read from the fuel sender wire to the Analog Input of your Teltonika device.
 +