Default Parameters Values Update

From Wiki Knowledge Base | Teltonika GPS

Default Parameters Values Update

Starting from firmware 03.29.00.Rev.04 default values of some parameters is updated to provide more comfortable solution for clients List of changes:

Name Default value in 03.27.XX firmware versions Default value in 03.29.XX firmware versions
Sleep Settings) 2 - (Deep Sleep) 3 - (Online Deep Sleep)
Sleep Timeout (minutes)) 1440 120
Allow AGPS in Home Network) 1 - (Enable) 0 - (Disabled)
Max Acceleration, m/s^2) 2.50 2.31
Max Braking, m/s^2) 2.70 2.52
Max Cornering, rad/s) 3.40 2.94
Unplug Detection Mode) 0 - (Simple) 1 - (Advanced)
Duration, ms) 20 10
Crash Trace) 0 - (Disable) 2 - (Trace Full)
X geozone, Generate Event) 0 - (No Event) 3 - (On Both)
Scan retries until error, seconds) 30 10
Program number) 0 11120
Data Acquisition Change) 0 11120

Review all parameter setting in https://wiki.teltonika-gps.com/view/FMB920_Parameter_list