FTC881 Parameter list

From Wiki Knowledge Base | Teltonika GPS
Revision as of 15:53, 16 October 2023 by Mantas.Kraujelis (talk | contribs) (Created page with "{{Template:FTXXXX Device Family Parameter list}} 6")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > Fast & Easy Trackers > FTC881 > FTC881 Manual > FTC881 Parameter list

Mobile network

Mobile data settings

SIM 1 Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2001 Char "" 0 32 String APN
2002 Char "" 0 32 String APN username
2003 Char "" 0 32 String APN password
2016 Uint8 1 0 1 0 – PAP GPRS authentication
1 – CHAP

Server Settings

Primary server settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2004 Char "" 0 55 String Domain
2005 Uint16 0 0 65535 Number Port
2006 Uint8 0 0 3 0 – TCP Protocol
1 – UDP

Server communication settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1000 Uint32 300 30 259200 Seconds Open link timeout
1001 Uint16 30 5 300 Seconds Response timeout
1003 Uint16 0 0 300 Seconds Keep-alive

FOTA WEB settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13003 Uint8 1 0 1 0 - Disable FOTA WEB Settings
1 – Enable
13000 Char fm.teltonika.lt 0 55 String Domain
13001 Uint16 5005 0 65535 Number Port
13001 Uint16 5055 0 65535 Number Pinger port

System parameters

Ignition settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
101 Uint8 4 2 7 1 – Digital Input Ignition settings
2 – Power Voltage
3 – Digital Input or Power Voltage
4 - Accelerometer
5 - Digital Input or Accelerometer
6 - Accelerometer or Power Voltage
7 – Digital Input, Accelerometer or Power Voltage
104 Uint16 30000 0 30000 mV High voltage
105 Uint16 13200 0 29999 mV Low voltage

Movement settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
138 Uint8 2 1 15 1 – Accelerometer Movement source
2 – GNSS
3 – Accelerometer or GNSS
4 - Power Voltage
5 - Accelerometer or Power Voltage
6 - GNSS or Power Voltage
7 – Accelerometer, GNSS or Power Voltage
8 – Digital Input
9 – Accelerometer or Digital Input
10 – Digital Input or GNSS
12 – Digital Input or Power Voltage
15 – Accelerometer, GNSS, Power Voltage or Digital Input
139 Uint16 30000 0 30000 mV High voltage
140 Uint16 13200 0 29999 mV Low voltage

GNSS settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
121 Uint8 10 1 15 1 – GPS GNSS source
3 – GPS, GNLONASS
5 – GPS, Galileo
9 – GPS and BeiDou
15 – GPS, Galileo, GLONASS and BeiDou

Movement Delay

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11206 Uint16 2 1 60 Seconds Movement Start Delay
11205 Uint16 60 5 300 Seconds Movement Stop Delay

Time synchronization settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
901 Uint8 3 0 24 Hours NTP resync
902 Char "pool.ntp.org" 0 55 String NTP server 1
903 Char "time.nist.gov" 0 55 String NTP server 2

Battery settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
110 Uint8 0 0 1 0 – On need Battery charge mode
1 – After ignition ON
2 – Always

LED indication

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
108 Uint8 1 0 1 0 – Disable LED Indication
1 – Enable

Tracking settings

Records settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
107 Uint8 2 0 2 0 – After position fix Saving sending mode
1 – Always
2 – After time sync
1002 Uint8 0 0 1 0 – Newest Sort by
1 – Oldest
113 Uint8 1 1 1 1 – Codec 8 Extended
Data Protocol

Records profile settings

On Stop

Home

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10000 Uint16 3600 0 2592000 Min Period
10004 Uint8 1 1 255 Min Saved Records
10005 Uint16 120 0 2592000 Send Period

Roaming

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10100 Uint16 3600 0 2592000 Min Period
10104 Uint8 1 1 255 Min Saved Records
10105 Uint16 0 0 2592000 Send Period

Moving

Home

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10050 Uint16 300 0 2592000 Min Period
10051 Uint16 100 0 65535 Min Distance
10052 Uint8 10 0 180 Min Angle
10053 Uint8 10 0 100 Min Speed Delta
10054 Uint8 1 1 255 Min Saved Records
10055 Uint16 120 0 2592000 Send Period

Roaming

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
10150 Uint16 300 0 2592000 Min Period
10151 Uint16 100 0 65535 Min Distance
10152 Uint8 10 0 180 Min Angle
10153 Uint8 10 0 100 Min Speed Delta
10154 Uint8 1 1 255 Min Saved Records
10155 Uint16 0 0 2592000 Send Period

Features

Driving behavior

Overspeeding

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025500 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11104 Uint16 90 0 260 km/h Max speed

Trip

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025000 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11803 Uint8 5 0 255 km/h Start speed
11804 Uint16 60 0 65535 Seconds Ignition OFF timeout

Odometer

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1001600 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority
11807 Uint32 0 0 4294967 Kilometer Odometer value


Vehicle protection

Unplug Detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1025200 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

Other features

Static navigation

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
106 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

Digital output overcurrent recovery

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
350 Uint8 0 0 2 0 – Disable Priority
1 – Low priority
2 – High priority

SMS / Call settings

SMS Security

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3004 Char "" 0 5 String Password

Input / output (I/O)

Parameter ID Parameter Type Default value Value range Parameter name
Min Max
1023900 Uint8 1 0 2 Ignition Priority
1023903 Uint8 1 0 4 Ignition Operand
1023902 Uint8 0 0 1 Ignition High level
1023901 Uint8 0 0 1 Ignition Low level
1023904 Uint8 0 0 1 Ignition Event only
1024000 Uint8 1 0 2 Movement Priority
1024003 Uint8 2 0 4 Movement Operand
1024002 Uint8 0 0 1 Movement High level
1024001 Uint8 0 0 1 Movement Low level
1024004 Uint8 0 0 1 Movement Event only
1030300 Uint8 0 0 2 Instant movement Priority
1030303 Uint8 2 0 4 Instant movement Operand
1030302 Uint8 0 0 1 Instant movement High level
1030301 Uint8 0 0 1 Instant movement Low level
1030304 Uint8 0 0 1 Instant movement Event only
1002100 Uint8 1 0 2 GSM Signal Priority
1002103 Uint8 0 0 6 GSM Signal Operand
1002102 Uint8 0 0 1 GSM Signal High level
1002101 Uint8 0 0 1 GSM Signal Low level
1002104 Uint8 0 0 1 GSM Signal Event only
1080000 Uint8 1 0 2 External Voltage Priority
1080003 Uint8 0 0 6 External Voltage Operand
1080002 Uint8 0 0 1 External Voltage High level
1080001 Uint8 0 0 1 External Voltage Low level
1080004 Uint8 0 0 1 External Voltage Event only
1020600 Uint8 0 0 2 GSM area code Priority
1020603 Uint8 0 0 6 GSM area code Operand
1020602 Uint8 0 0 1 GSM area code High level
1020601 Uint8 0 0 1 GSM area code Low level
1020604 Uint8 0 0 1 GSM area code Event only
1006700 Uint8 1 0 2 Battery voltage Priority
1006703 Uint8 0 0 6 Battery voltage Operand
1006702 Uint8 0 0 1 Battery voltage High level
1006701 Uint8 0 0 1 Battery voltage Low level
1006704 Uint8 0 0 1 Battery voltage Event only
1006800 Uint8 1 0 2 Battery current Priority
1006803 Uint8 0 0 6 Battery current Operand
1006802 Uint8 0 0 1 Battery current High level
1006801 Uint8 0 0 1 Battery current Low level
1006804 Uint8 0 0 1 Battery current Event only
1019900 Uint8 0 0 2 Trip odometer Priority
1019903 Uint8 0 0 6 Trip odometer Operand
1019902 Uint8 0 0 1 Trip odometer High level
1019901 Uint8 0 0 1 Trip odometer Low level
1019904 Uint8 0 0 1 Trip odometer Event only
1001600 Uint8 1 0 2 Total Odometer Priority
1001603 Uint8 0 0 6 Total Odometer Operand
1001602 Uint8 0 0 1 Total Odometer High level
1001601 Uint8 0 0 1 Total Odometer Low level
1001604 Uint8 0 0 1 Total Odometer Event only
1000100 Uint8 0 0 2 Digital Input 1 Priority
1000103 Uint8 0 0 6 Digital Input 1 Operand
1000102 Uint8 0 0 1 Digital Input 1 High level
1000101 Uint8 0 0 1 Digital Input 1 Low level
1000104 Uint8 0 0 1 Digital Input 1 Event only
1000900 Uint8 0 0 2 Analog Input 1 Priority
1000903 Uint8 0 0 6 Analog Input 1 Operand
1000902 Uint8 0 0 1 Analog Input 1 High level
1000901 Uint8 0 0 1 Analog Input 1 Low level
1000904 Uint8 0 0 1 Analog Input 1 Event only
1017900 Uint8 0 0 2 Digital Output 1 Priority
1017903 Uint8 0 0 6 Digital Output 1 Operand
1017902 Uint8 0 0 1 Digital Output 1 High level
1017901 Uint8 0 0 1 Digital Output 1 Low level
1017904 Uint8 0 0 1 Digital Output 1 Event only
1084100 Uint8 1 0 2 Digital Output 1 overcurrent Priority
1084103 Uint8 0 0 6 Digital Output 1 overcurrent Operand
1084102 Uint8 0 0 1 Digital Output 1 overcurrent High level
1084101 Uint8 0 0 1 Digital Output 1 overcurrent 1 Low level
1084104 Uint8 0 0 1 Digital Output 1 overcurrent Event only
1064100 Uint8 0 0 2 ICCID Priority
1064103 Uint8 0 0 6 ICCID Operand
1064102 Uint8 0 0 1 ICCID overcurrent High level
1064101 Uint8 0 0 1 ICCID overcurrent 1 Low level
1064104 Uint8 0 0 1 ICCID Event only