Difference between revisions of "Template:FMB9 Features settings"

From Wiki Knowledge Base | Teltonika GPS
(Created page with "== DOUT Control Via Call== {{{pic_dout_control|300px|right}}} Scenario is activated and digital output is ON when call is received from a...")
 
m
 
Line 6: Line 6:
 
Call control functionality is following:
 
Call control functionality is following:
 
* When {{{model|FMB9YX}}} is configured to control DOUT1 the device waits for an incoming call from a configured secure number. If a call is received {{{model|FMB9YX}}} turns on DOUT1 for a user defined ''Duration Timeout''. If duration timeout set to "0" DOUT1 will be OFF.
 
* When {{{model|FMB9YX}}} is configured to control DOUT1 the device waits for an incoming call from a configured secure number. If a call is received {{{model|FMB9YX}}} turns on DOUT1 for a user defined ''Duration Timeout''. If duration timeout set to "0" DOUT1 will be OFF.
* DOUT1 can be turned off by ''Duration Timeout'' or by digital input 1.
+
* DOUT1 can be turned off by ''Duration Timeout'' or by DIN1.
 
* DOUT1 will always be ON if, for example, DOUT deactivation is set to DIN1, but DIN1 will be never turned ON, or when duration timeout is set to maximum value (2147483647) which is about 68 years.
 
* DOUT1 will always be ON if, for example, DOUT deactivation is set to DIN1, but DIN1 will be never turned ON, or when duration timeout is set to maximum value (2147483647) which is about 68 years.

Latest revision as of 08:30, 30 July 2018

DOUT Control Via Call

Fmb920 dout via call.png

Scenario is activated and digital output is ON when call is received from a number which is on the authorized numbers list.
Call control functionality is following:

  • When FMB9YX is configured to control DOUT1 the device waits for an incoming call from a configured secure number. If a call is received FMB9YX turns on DOUT1 for a user defined Duration Timeout. If duration timeout set to "0" DOUT1 will be OFF.
  • DOUT1 can be turned off by Duration Timeout or by DIN1.
  • DOUT1 will always be ON if, for example, DOUT deactivation is set to DIN1, but DIN1 will be never turned ON, or when duration timeout is set to maximum value (2147483647) which is about 68 years.