Product change notifications (PCN) is the way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, firmware changes, changes to package contents, etc.
This page stores information regarding changes to the FMB140 tracking device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).
2024.05.13: Base firmware update
We would like to inform you about the base firmware update for FMB140 starting from June, 2024. New production firmware version will be 03.29.00.Rev.18
Change description
Change type
Firmware update
Detailed description
Key improvements from last production firmware are listed in errata: FMB140 firmware errata
Old version: 03.29.00.Rev.13
New version: 03.29.00.Rev.18
Change reasons
FMB140 base firmware version update
Product release date
2024 June
Affected products
Model
Affected order codes
Order code changes
FMB140
Order codes with base Firmware
New firmware version
Change impact
Risk assessment
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
2023.02.02: Changes in side frame for the battery placement
We would like to inform you that the side frame for the battery placement is included, helping to determine the exact location of the battery. Also, minor design changes are made to improve both case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices. The updates in the factory are being implemented in February, 2023.
Change description
Change type
Internal
Detailed description
The side frame for the battery placement is included, helping to determine the exact location of the battery. Also, minor design changes are made to improve both case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices.
Old Version:
New Version:
Change reasons
The battery placement is improved with a side frame, helping to determine the exact location of the battery. Minor design changes are made for case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices.
Updated the battery placement with the side frame as well as minor design changes for case production and assembly
Change impact
Risk assessment
During the transition period clients might receive devices with old case design used in manufacture
Suggested implementation plan
Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
2022.08.01: Base firmware update
We would like to inform you about the base firmware update for FMB140 starting from August 1st, 2022. New production firmware version will be 03.27.13.Rev.03
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
2021.04.30: Bluetooth® Improvement
We would like to inform you, that Bluetooth® performance for the FMB140 device will be updated in the factory from August 2021.
Change description
Change type
Internal
Detailed description
Bluetooth® antennas are improved for FMB140 device ensuring better signal strength. The efficiency of Bluetooth® antennas is considerably increased when receiving or transferring data.
Change reasons
Following the changes, the capabilities of our devices will be greatly improved to provide better performance when Bluetooth® signal is obstructed or longer distance coverage is required
Product release date
August 2021
Affected products
Model
Affected order codes
Order code changes
FMB140
FMB140******* order codes with base Firmware
No changes
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2021.04.16: Top Laser Printing Changes
We would like to inform you, that laser printing of the FMB140 device was updated in the factory on April 2021.
Change description
Change type
External/visual
Detailed description
Top laser printing design changed
Old version:
New version:
Change reasons
1. Added ANATEL label and certificate number.
Product release date
April 2021
Affected products
Model
Affected order codes
Order code changes
FMB140
FMB140*******
New casing
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
2020.12.01: Top Laser Printing Changes
We would like to inform you, that laser printing of the FMB140 device was updated in the factory in December 2020.
Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2020.10.05: Base firmware update
We would like to inform you about the base firmware update for FMB140 starting from October 05th, 2020. The new production firmware version will be 03.25.16.Rev.281.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
2019.12.02: Top Device Marking Changes
We would like to inform you, that tampography of the FMB140 device was updated to engraving in the factory on the 2nd of December.
Change description
Change type
External/visual
Detailed description
Device marking changed from tampography to laser printing. Information provided on module will remain the same
Old Version:
New Version:
Change reasons
To improve manufacturing speed, efficiency and reliability
To increase quality, precision and durability of marking.
Product release date
Planned date: 2019 December
Affected products
Model
Affected order codes
Order code changes
FMB140
FMB140*******
No changes
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2019.12.01: Top Label Changes
We would like to inform you, that label of the FMB140 device was updated in the factory in December 2019.
Updated label will be used from the time when the stock will be sold all leftovers. Planned date: from December, 2019
Affected products
Model
Affected order codes
Order code changes
FMB140
FMB140*******
No changes
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above